Residual current circuit breaker (RCCB), Multi9 GFP, 2P, 40A, A-SI type, 30mA, 480Y/277VAC

MULTI9 GFP 2P 40A 26MA A 480Y/

SQDM9R41240 M9R41240 3606481198495
682.54 / EA
http://schema.org/OutOfStock
  • Country of Origin: Spain
  • Depth: 60 mm
  • Height: 81 mm
  • Net Weight: 0.22 kg
  • Weight: 0.22 kg
  • Width: 36 mm
This is a Multi GFP residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, A-SI type protection class and a 26mA earth leakage sensitivity. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 60mm. The weight is 0.22kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.
QTY
  • Product Description
  • Specifications
This is a Multi GFP residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, A-SI type protection class and a 26mA earth leakage sensitivity. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 60mm. The weight is 0.22kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.
  • Specifications
    • Country of Origin : Spain
    • Width : 36 mm
    • Height : 81 mm
    • Weight : 0.22 kg
    • Line Rated Current : 40 A 40 °C EN/IEC 61008-1
    • Network Type : AC
    • Earth-Leakage Sensitivity : 26 mA UL 1053 || 30 mA EN/IEC 61008-1
    • Product Or Component Type : residual current circuit breaker (RCCB)
    • Product Name : Multi9 GFP
    • Utilisation Category : AC-23A EN/IEC 61008-1
    • Earth-Leakage Protection Time Delay : instantaneous
    • Poles Description : 2P
    • Neutral Position : left
    • Standards : EN/IEC 61008-1 || UL 1053
    • Earth-Leakage Protection Class : type A-SI (Super Immunised)
    • Product Certifications : IEC || UL
    • Range : Multi9
    • Device Application : distribution
    • Device Short Name : GFP
  • Complementary
    • Network Frequency : 50/60 Hz
    • Contact Position Indicator : yes
    • Mounting Support : DIN rail
    • 9 Mm Pitches : 4
    • Connections - Terminals : tunnel type terminals top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible || tunnel type terminals top or bottom) 1-35 mm² AWG 18...AWG 2) - rigid || tunnel type terminals top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible with ferrule
    • Net Weight : 0.22 kg
    • [Ui] Rated Insulation Voltage : 440 V AC 50/60 Hz
    • Local Signalling : ON, OFF, fault trip
    • Width : 36 mm
    • Depth : 60 mm
    • Rated Conditional Short-Circuit Current : Inc 10 kA 100 A gG
    • [Ue] Rated Operational Voltage : 480Y/277 V AC 60 Hz || 240/415 V AC 50 Hz
    • Height : 81 mm
    • Locking Options Description : padlocking in OFF position
    • Wire Stripping Length : 14 mm for top or bottom connection
    • Control Type : toggle
    • Residual Current Tripping Technology : voltage independent
    • Mounting Mode : clip-on
    • Rated Breaking And Making Capacity : Idm 1500 A EN/IEC 61008-1
    • Mechanical Durability : 20000 cycles
    • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 61008-1
    • Color : Gray
    • Tightening Torque : 3.5-3.5 N.m top or bottom
  • Environmental data
    • Mercury Free : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Take-Back : No
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 2.6518002301056183
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 42 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 42.1605723035152
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP2301023EN
    • Halogen Content Performance : Product contains halogen above thresholds
    • Packaging Without Single Use Plastic : Yes
    • Scip Number : 81454b7e-fcdf-4818-a481-efccd54a351f
    • Carbon Footprint Of The Installation Phase [A5] : 0.016308929372384894
    • Circularity Profile : N/A
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 38.776666666666664
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 0.7 kg CO2 eq.
    • Carbon Footprint Of The Distribution Phase [A4] : 0 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
  • Environment
    • Ambient Air Temperature For Operation : -25-60 °C
    • Tropicalisation : 2 IEC 60068-1
    • Electromagnetic Compatibility : 8/20 µs impulse withstand, 3000 A EN/IEC 61008-1
    • Ip Degree Of Protection : IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
    • Pollution Degree : 3
    • Ambient Air Temperature For Storage : -40-70 °C
    • Relative Humidity : 95-95 % 55-55 °C