Multi9 - GFP - RCCB - 2P - 40A - class A SI - 240 V - 26 mA instantaneous

Multi9 - GFP - RCCB - 2P - 40A - class A SI - 240 V - 26 mA instantaneous

SQDM9R81240 M9R81240 785901762010
374.86 / EA
  • Amperage: 40 A
  • Certifications: IEC, UL
  • Country of Origin: Spain
  • Depth: 2.36 in, 60 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: EN/IEC 61008-1, UL 1053
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 120/240 V, 240 V
  • Weight: 0.22 kg, 0.49 lb
  • Width: 1.42 in, 36 mm
This is a Multi GFP residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, A-SI type protection class and a 26mA earth leakage sensitivity. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 60mm. The weight is 0.22kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.
  • Product Description
  • Specifications
This is a Multi GFP residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, A-SI type protection class and a 26mA earth leakage sensitivity. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 60mm. The weight is 0.22kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.
  • Environment
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Tropicalisation : 2 conforming to IEC 60068-1
    • Pollution Degree : 3
    • Standards : EN/IEC 61008-1 || UL 1053
    • Ambient Air Temp For Storage : -40…158 °F (-40…70 °C)
    • Product Certifications : IEC || UL
    • Ambient Air Temp For Op : -13…140 °F (-25…60 °C)
    • IP Degree Of Protection : IP20IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
    • Electromagnetic Compatibility : 8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61008-1
  • Main
    • Poles Description : 2P
    • In Rated Current : 40 A 104 °F (40 °C) EN/IEC 61008-1
    • Utilisation Category : AC-23A EN/IEC 61008-1
    • Device Short Name : GFP
    • Earth-Leak Protect Time Delay : Instantaneous
    • Product Name : Multi 9 GFP
    • Earth-Leakage Sensitivity : 26 mA UL 1053 || 30 mA EN/IEC 61008-1
    • Device Application : Distribution
    • Earth-Leakage Protection Class : Type A-SI (Super Immunised)
    • Neutral Position : Left
    • Range : Multi 9
    • Network Type : AC
    • Product Or Component Type : Residual current circuit breaker (RCCB)
  • Offer Sustainability
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • EU RoHs Directive : Compliant
    • Mercury Free : Yes
    • Green Premium Status : Green Premium product
  • Ordering And Shipping Details
    • Returnability : Yes
    • Nbr. Of Units In Pkg. : 1
    • Discount Schedule : DE2
    • GTIN : 00785901762010
    • Country Of Origin : ES
    • Category : 00948 - M9 GEN 2 CB UL1077 / IEC
  • Complementary
    • Network Frequency : 50/60 Hz
    • Rtd Cond Short-Cct Current : Inc 10 kA 100 A gG
    • Rated Brking And Making Cap : Idm 1500 A EN/IEC 61008-1
    • Depth : 2.36 in (60 mm)
    • Mechanical Durability : 20000 cycles
    • Mounting Mode : Clip-on
    • Connections - Terminals : Tunnel type terminals top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible || Tunnel type terminals top or bottom) 0.00…0.05 in² (1…35 mm²) AWG 18...AWG 2) - rigid || Tunnel type terminals top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible with ferrule
    • Mounting Support : DIN rail
    • Contact Position Indicator : Yes
    • Ue Rated Operational Voltage : 120/240 V AC 60 Hz || 240 V AC 50 Hz
    • Height : 3.19 in (81 mm)
    • Control Type : Toggle
    • Local Signalling : ON, OFF, fault trip
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • 9 mm Pitches : 4
    • Width : 1.42 in (36 mm)
    • Tightening Torque : 30.98 lbf.in (3.5 N.m) top or bottom
    • Colour : Gray
    • Resid Current Tripping Techno : Voltage independent
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 61008-1
    • Product Weight : 0.49 lb(US) (0.22 kg)
    • Ui Rated Insulation Voltage : 440 V AC 50/60 Hz
    • Locking Options Description : Padlocking in OFF position