Schneider Electric at Mayer

Multi9 - GFP - RCCB - 2P - 25A - class A SI - 240 V - 260 mA instantaneous

MULTI9 GFP 2P 25A 260MA A 120-

SQDM9R84225 M9R84225 785901761938
249.91 / EA
  • Amperage: 25 A
  • Certifications: IEC, UL
  • Country of Origin: Spain
  • Depth: 2.36 in, 60 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: EN/IEC 61008-1, UL 1053
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 120/240 V, 240 V
  • Weight: 0.22 kg, 0.49 lb
  • Width: 1.42 in, 36 mm
This Multi GFP product is a residual current circuit breaker (RCCB). It is a 2P circuit breaker with 25A In rated current, 260mA earth leakage sensitivity and A-SI type protection class. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 60mm. The weight is 0.22kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.
  • Product Description
  • Specifications
This Multi GFP product is a residual current circuit breaker (RCCB). It is a 2P circuit breaker with 25A In rated current, 260mA earth leakage sensitivity and A-SI type protection class. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 60mm. The weight is 0.22kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.
  • Main
    • Network Type : AC
    • Utilisation Category : AC-23A EN/IEC 61008-1
    • Earth-Leakage Sensitivity : 260 mA UL 1053 || 300 mA EN/IEC 61008-1
    • Neutral Position : Left
    • Earth-Leakage Protection Class : Type A-SI (Super Immunised)
    • Earth-Leak Protect Time Delay : Instantaneous
    • Device Short Name : GFP
    • In Rated Current : 25 A 104 °F (40 °C) EN/IEC 61008-1
    • Device Application : Distribution
    • Product Or Component Type : Residual current circuit breaker (RCCB)
    • Poles Description : 2P
    • Product Name : Multi 9 GFP
    • Range : Multi 9
  • Ordering And Shipping Details
    • GTIN : 00785901761938
    • Discount Schedule : DE2
    • Category : 00948 - M9 GEN 2 CB UL1077 / IEC
    • Nbr. Of Units In Pkg. : 1
    • Country Of Origin : ES
    • Returnability : Yes
  • Complementary
    • Contact Position Indicator : Yes
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 61008-1
    • Colour : Gray
    • Product Weight : 0.49 lb(US) (0.22 kg)
    • Ui Rated Insulation Voltage : 440 V AC 50/60 Hz
    • Mounting Support : DIN rail
    • Network Frequency : 50/60 Hz
    • Depth : 2.36 in (60 mm)
    • Ue Rated Operational Voltage : 120/240 V AC 60 Hz || 240 V AC 50 Hz
    • Resid Current Tripping Techno : Voltage independent
    • Rtd Cond Short-Cct Current : Inc 10 kA 100 A gG
    • Height : 3.19 in (81 mm)
    • Locking Options Description : Padlocking in OFF position
    • Tightening Torque : 30.98 lbf.in (3.5 N.m) top or bottom
    • Mechanical Durability : 20000 cycles
    • Local Signalling : ON, OFF, fault trip
    • Connections - Terminals : Tunnel type terminals top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible || Tunnel type terminals top or bottom) 0.00…0.05 in² (1…35 mm²) AWG 18...AWG 2) - rigid || Tunnel type terminals top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible with ferrule
    • Width : 1.42 in (36 mm)
    • Control Type : Toggle
    • 9 mm Pitches : 4
    • Mounting Mode : Clip-on
    • Rated Brking And Making Cap : Idm 1500 A EN/IEC 61008-1
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
  • Offer Sustainability
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Green Premium Status : Green Premium product
    • Mercury Free : Yes
    • EU RoHs Directive : Compliant
  • Environment
    • Electromagnetic Compatibility : 8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61008-1
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Pollution Degree : 3
    • Ambient Air Temp For Op : -13…140 °F (-25…60 °C)
    • IP Degree Of Protection : IP20IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
    • Tropicalisation : 2 conforming to IEC 60068-1
    • Ambient Air Temp For Storage : -40…158 °F (-40…70 °C)
    • Product Certifications : IEC || UL
    • Standards : EN/IEC 61008-1 || UL 1053