Schneider Electric at Mayer

Multi9 - C60SP - MCB - 4P - 10 A - C Curve - 480Y/277 V - 10 kA - UL 1077

Multi9 C60SP 4P C 10A MCB

SQDM9F22410 M9F22410 785901743163
234.14 / EA
  • Amperage: 10 A
  • Certifications: CCC, CSA, IEC, UR
  • Country of Origin: France
  • Depth: 2.83 in, 72 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: CSA C22.2 No 235, EN/IEC 60947-2, GB 14048.2, UL 1077
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 240 V, 415 V, 440 V
  • Width: 2.83 in, 72 mm
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 4P circuit breaker with 4 protected poles, 10A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 8 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 4P circuit breaker with 4 protected poles, 10A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 8 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Complementary
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 8) - rigid || Tunnel type terminal top or bottom) 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 8) - flexible with ferrule || Tunnel type terminal top or bottom) 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 8) - flexible
    • Ui Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
    • Earth-Leakage Protection : Without
    • Colour : Gray
    • Electrical Durability : 10000 cycles
    • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • Depth : 2.83 in (72 mm)
    • Mounting Support : DIN rail
    • Tightening Torque : 22.13 lbf.in (2.5 N.m) top or bottom
    • Provision For Padlocking : Padlockable
    • Control Type : Toggle
    • Height : 3.19 in (81 mm)
    • Mechanical Durability : 20000 cycles
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • Contact Position Indicator : Yes
    • Ics Rated Service Breaking Cap : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
    • Ue Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
    • Width : 2.83 in (72 mm)
    • 9 mm Pitches : 8
    • Mounting Mode : Clip-on
    • Local Signalling : ON/OFF indication
  • Environment
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Ambient Air Temp For Op : -22…158 °F (-30…70 °C)
    • IP Degree Of Protection : IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
    • Pollution Degree : 3 EN/IEC 60947-2
    • Tropicalisation : 2 IEC 60068-1
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Relative Humidity : 95 % 131 °F (55 °C)
  • Offer Sustainability
    • Mercury Free : Yes
    • EU RoHs Directive : Compliant
    • Halogen Content Performance : Halogen free product
    • Green Premium Status : Green Premium product
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • Main
    • In Rated Current : 10 A 77 °F (25 °C) EN/IEC 60947-2
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 1077 || CSA C22.2 No 235
    • Device Application : Distribution
    • Breaking Capacity : 14 kA AIR 240 V AC UL 1077 || 14 kA AIR 240 V AC CSA C22.2 No 235 || 10 kA AIR 480Y/277 V AC UL 1077 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 235 || 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2
    • Network Type : AC
    • Product Or Component Type : Miniature circuit-breaker
    • Device Short Name : C60SP
    • Product Name : Multi 9 C60
    • Range : Multi 9
    • Trip Unit Technology : Thermal-magnetic
    • Number Of Protected Poles : 4
    • Poles Description : 4P
    • Curve Code : C
    • Product Certifications : IEC || CCC || UR || CSA
    • Suitability For ISOlation : Yes EN/IEC 60947-2
  • Ordering And Shipping Details
    • Category : 00948 - M9 GEN 2 CB UL1077 / IEC
    • Discount Schedule : DE2
    • Nbr. Of Units In Pkg. : 1
    • GTIN : 00785901743163
    • Returnability : Yes
    • Country Of Origin : FR