Multi9 - C60SP - MCB - 3P - 10 A - B Curve - 480Y/277 V - 10 kA - UL 1077

Multi9 - C60SP - MCB - 3P - 10 A - B Curve - 480Y/277 V - 10 kA - UL 1077

SQDM9F21310 M9F21310 785901736127
177.30 / EA
  • Certifications: CCC, CSA, IEC, UR
  • Depth: 72 mm
  • Height: 81 mm
  • Line Rated Current: 10 A, 25 °C
  • Mounting Type: Clip-On
  • Operating Temperature: -30-70 °C
  • Standard: CSA C22.2 No 235, EN/IEC 60947-2, GB 14048.2, UL 1077
  • Storage Temperature: -40-80 °C
  • Strip Length: 14 mm
  • Width: 54 mm
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 10A rated current and B tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 10A rated current and B tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Control Type : toggle
  • Product Or Component Type : miniature circuit-breaker
  • Product Name : Multi 9 C60
  • Mounting Support : DIN rail
  • Product Certifications : IEC || CCC || UR || CSA
  • Curve Code : B
  • Breaking Capacity : 14 kA AIR 240 V AC UL 1077 || 14 kA AIR 240 V AC CSA C22.2 No 235 || 10 kA AIR 480Y/277 V AC UL 1077 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 235 || 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2
  • Wire Stripping Length : 14 mm top or bottom
  • [Ics] Rated Service Breaking Capacity : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
  • Mounting Mode : clip-on
  • [Ui] Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
  • Mechanical Durability : 20000 cycles
  • Local Signalling : ON/OFF indication
  • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 1077 || CSA C22.2 No 235
  • Device Application : distribution
  • Magnetic Tripping Limit : 4 x In +/- 20 % AC
  • Color : Gray
  • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2
  • Suitability For Isolation : yes EN/IEC 60947-2
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
  • Line Rated Current : 10 A 25 °C EN/IEC 60947-2
  • Connections - Terminals : tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 8) - rigid || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible with ferrule || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible
  • Maximum Width : 54 mm
  • Range Of Product : Multi 9
  • Ambient Air Temperature For Operation : -30-70 °C
  • Ambient Air Temperature For Storage : -40-80 °C
  • Provision For Padlocking : padlockable
  • Pollution Degree : 3 EN/IEC 60947-2
  • Maximum Height : 81 mm
  • Number Of Protected Poles : 3
  • Operating Altitude : 0...6561.68 ft (0...2000 m)
  • 9 Mm Pitches : 6
  • Earth-Leakage Protection : without
  • Tropicalisation : 2 IEC 60068-1
  • Poles Description : 3P
  • Maximum Depth : 72 mm
  • Network Type : AC
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • Range : Multi 9
  • Trip Unit Technology : thermal-magnetic
  • Device Short Name : C60SP
  • Contact Position Indicator : yes
  • Relative Humidity : 95-95 % 55-55 °C
  • Tightening Torque : 2.5-2.5 N.m top or bottom
  • Electrical Durability : 10000 cycles