Multi9 - C60SP - MCB - 2P - 6 A - C Curve - 480Y/277 V - 10 kA - UL 1077

Multi9 - C60SP - MCB - 2P - 6 A - C Curve - 480Y/277 V - 10 kA - UL 1077

SQDM9F22206 M9F22206 785901721192
122.70 / EA
  • Certifications: CCC, CSA, IEC, UR
  • Depth: 72 mm
  • Height: 81 mm
  • Line Rated Current: 25 °C, 6 A
  • Operating Temperature: -30-70 °C
  • Standard: CSA C22.2 No 235, EN/IEC 60947-2, GB 14048.2, UL 1077
  • Storage Temperature: -40-80 °C
  • Strip Length: 14 mm
  • Width: 36 mm
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 6A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 6A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Ambient Air Temperature For Operation : -30-70 °C
  • Ambient Air Temperature For Storage : -40-80 °C
  • Tropicalisation : 2 IEC 60068-1
  • Electrical Durability : 10000 cycles
  • Number Of Protected Poles : 2
  • Curve Code : C
  • [Ics] Rated Service Breaking Capacity : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
  • Maximum Height : 81 mm
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
  • Range : Multi 9
  • Operating Altitude : 0...6561.68 ft (0...2000 m)
  • Local Signalling : ON/OFF indication
  • Product Certifications : IEC || CCC || UR || CSA
  • Tightening Torque : 2.5-2.5 N.m top or bottom
  • Contact Position Indicator : yes
  • Maximum Depth : 72 mm
  • Suitability For Isolation : yes EN/IEC 60947-2
  • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2
  • Wire Stripping Length : 14 mm top or bottom
  • Range Of Product : Multi 9
  • Connections - Terminals : tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 8) - rigid || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible with ferrule || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible
  • Product Name : Multi 9 C60
  • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 1077 || CSA C22.2 No 235
  • [Ui] Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
  • Network Type : DC || AC
  • Relative Humidity : 95-95 % 55-55 °C
  • Provision For Padlocking : padlockable
  • Trip Unit Technology : thermal-magnetic
  • Maximum Width : 36 mm
  • Line Rated Current : 6 A 25 °C EN/IEC 60947-2
  • Breaking Capacity : 14 kA AIR 240 V AC UL 1077 || 14 kA AIR 240 V AC CSA C22.2 No 235 || 10 kA AIR 480Y/277 V AC UL 1077 || 10 kA AIR 125 V DC UL 1077 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 235 || 10 kA AIR 125 V DC CSA C22.2 No 235 || 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2
  • Color : Gray
  • Mounting Support : DIN rail
  • Mechanical Durability : 20000 cycles
  • Pollution Degree : 3 EN/IEC 60947-2
  • 9 Mm Pitches : 4
  • Control Type : toggle
  • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC || 12 x In +/- 20 % DC
  • Product Or Component Type : miniature circuit-breaker
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • Device Application : distribution
  • Poles Description : 2P
  • Device Short Name : C60SP
  • Earth-Leakage Protection : without
  • Mounting Mode : clip-on