Multi9 - C60SP - MCB - 2P - 5 A - D Curve - 480Y/277 V - 10 kA - UL 1077

Multi9 - C60SP - MCB - 2P - 5 A - D Curve - 480Y/277 V - 10 kA - UL 1077

SQDM9F23205 M9F23205 785901725947
122.70 / EA
  • Amperage: 5 A
  • Certifications: CCC, CSA, IEC, UR
  • Country of Origin: France
  • Depth: 2.83 in, 72 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: CSA C22.2 No 235, EN/IEC 60947-2, GB 14048.2, UL 1077
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 240 V, 415 V, 440 V
  • Width: 1.42 in, 36 mm
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 5A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 5A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Ordering And Shipping Details
    • GTIN : 00785901725947
    • Country Of Origin : FR
    • Discount Schedule : DE2
    • Returnability : Yes
    • Category : 00948 - M9 GEN 2 CB UL1077 / IEC
    • Nbr. Of Units In Pkg. : 1
  • Main
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 1077 || CSA C22.2 No 235
    • Suitability For ISOlation : Yes conforming to EN/IEC 60947-2
    • Product Certifications : IEC || CCC || UR || CSA
    • Poles Description : 2P
    • In Rated Current : 5 A 77 °F (25 °C) EN/IEC 60947-2
    • Network Type : AC || DC
    • Breaking Capacity : 14 kA AIR 240 V AC UL 1077 || 14 kA AIR 240 V AC CSA C22.2 No 235 || 10 kA AIR 480Y/277 V AC UL 1077 || 10 kA AIR 125 V DC UL 1077 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 235 || 10 kA AIR 125 V DC CSA C22.2 No 235 || 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2
    • Curve Code : D
    • Range : Multi 9
    • Device Application : Distribution
    • Product Or Component Type : Miniature circuit-breaker
    • Number Of Protected Poles : 2
    • Trip Unit Technology : Thermal-magnetic
    • Device Short Name : C60SP
    • Product Name : Multi 9 C60
  • Environment
    • IP Degree Of Protection : IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
    • Ambient Air Temp For Op : -22…158 °F (-30…70 °C)
    • Tropicalisation : 2 conforming to IEC 60068-1
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Pollution Degree : 3 EN/IEC 60947-2
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
  • Offer Sustainability
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Green Premium Status : Green Premium product
    • Halogen Content Performance : Halogen free product
    • EU RoHs Directive : Compliant
    • Mercury Free : Yes
  • Complementary
    • Height : 3.19 in (81 mm)
    • Electrical Durability : 10000 cycles
    • Mounting Mode : Clip-on
    • Depth : 2.83 in (72 mm)
    • Tightening Torque : 22.13 lbf.in (2.5 N.m) top or bottom
    • Earth-Leakage Protection : Without
    • Width : 1.42 in (36 mm)
    • Ics Rated Service Breaking Cap : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
    • Ue Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
    • Ui Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • Mounting Support : DIN rail
    • Provision For Padlocking : Padlockable
    • Colour : Gray
    • Contact Position Indicator : Yes
    • Mechanical Durability : 20000 cycles
    • Control Type : Toggle
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • 9 mm Pitches : 4
    • Local Signalling : ON/OFF indication
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 8) - rigid || Tunnel type terminal top or bottom) 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 8) - flexible with ferrule || Tunnel type terminal top or bottom) 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 8) - flexible
    • Magnetic Tripping Limit : 12 x In +/- 20 % AC || 17 x In +/- 20 % DC