Schneider Electric at Mayer

Multi9 - C60N - MCB - 4P - 63 A - C Curve - 415 V - 10 kA

MINIATURE CIRCUIT BREAKER 240/

SQDM9F11463 M9F11463 360648057657
0.00 / EA
  • Certifications: CCC, EAC
  • Depth: 72 mm
  • Height: 81 mm
  • Line Rated Current: 50 °C, 63 A
  • Mounting Type: Clip-On
  • Net Weight: 0.48 kg
  • Operating Temperature: -30-70 °C
  • Standard: EN/IEC 60947-2
  • Storage Temperature: -40-80 °C
  • Strip Length: 14 mm
  • Width: 72 mm
This Multi9 C60N is a low voltage miniature circuit breaker (MCB). It is a 4P circuit breaker with 4 protected poles, 63A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 8 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 81mm x (D) 72mm. The weight is 0.48kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60N is a low voltage miniature circuit breaker (MCB). It is a 4P circuit breaker with 4 protected poles, 63A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 8 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 81mm x (D) 72mm. The weight is 0.48kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Range Of Product : Multi 9
  • Wire Stripping Length : 14 mm top or bottom
  • Utilisation Category : category A EN/IEC 60947-2
  • Provision For Padlocking : padlockable
  • Network Type : DC || AC
  • Tropicalisation : 2 IEC 60068-1
  • Range : Multi 9
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • [Ics] Rated Service Breaking Capacity : 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC 50/60 Hz || 16 kA 75 % EN/IEC 60947-2 - 240 V AC 50/60 Hz || 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC 50/60 Hz || 40 kA 100 % EN/IEC 60947-2 - <= 250 V DC
  • Maximum Height : 81 mm
  • Net Weight : 0.48 kg
  • Breaking Capacity Code : N
  • Mechanical Durability : 20000 cycles
  • Maximum Width : 72 mm
  • Ambient Air Temperature For Storage : -40-80 °C
  • Heat Dissipation : 24.4-24.4 W 415 V - 63 A
  • Earth-Leakage Protection : separate block
  • Breaking Capacity : 40 kA Icu <= 250 V DC EN/IEC 60947-2 || 10 kA Icu 415 V AC 50/60 Hz between phases EN/IEC 60947-2 || 20 kA Icu 240 V AC 50/60 Hz between phases EN/IEC 60947-2 || 6 kA Icu 440 V AC 50/60 Hz between phases EN/IEC 60947-2
  • Color : Gray
  • Poles Description : 4P
  • Device Application : distribution
  • Standards : EN/IEC 60947-2
  • Trip Unit Technology : thermal-magnetic
  • 9 Mm Pitches : 8
  • Control Type : toggle
  • Suitability For Isolation : yes EN/IEC 60947-2
  • Product Certifications : EAC || CCC
  • Relative Humidity : 95-95 % 55-55 °C
  • Tightening Torque : 3.5-3.5 N.m top or bottom
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz between phases || 415 V AC 50/60 Hz between phases || 440 V AC 50/60 Hz between phases || <= 250 V DC
  • Product Or Component Type : miniature circuit-breaker
  • Connections - Terminals : tunnel type terminal top or bottom) 1.5-35 mm² - rigid || tunnel type terminal top or bottom) 1.5-35 mm² - flexible || tunnel type terminal top or bottom) 1.5-35 mm² - flexible with ferrule
  • Overvoltage Category : IV
  • Limitation Class : 3
  • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC || 12 x In +/- 20 % DC
  • Ambient Air Temperature For Operation : -30-70 °C
  • Contact Position Indicator : yes
  • Local Signalling : ON/OFF indication
  • Line Rated Current : 63 A 50 °C EN/IEC 60947-2
  • Network Frequency : 50/60 Hz
  • Curve Code : C
  • Electrical Durability : 10000 cycles
  • Mounting Support : DIN rail
  • [Ui] Rated Insulation Voltage : 500 V AC 50/60 Hz EN/IEC 60947-2
  • Pollution Degree : 3 EN/IEC 60947-2
  • Device Short Name : C60N
  • Maximum Depth : 72 mm
  • Number Of Protected Poles : 4
  • Mounting Mode : clip-on
  • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2
  • Product Name : Multi 9 C60