Multi9 - C60N - MCB - 2P - 2 A - D Curve - 415 V - 10 kA

MINIATURE CIRCUIT BREAKER 240/

SQDM9F12202 M9F12202 360648057670
0.00 / EA
  • Certifications: CCC, EAC, KC
  • Depth: 72 mm
  • Height: 81 mm
  • Line Rated Current: 2 A, 50 °C
  • Mounting Type: Clip-On
  • Net Weight: 0.24 kg
  • Operating Temperature: -30-70 °C
  • Standard: EN/IEC 60947-2
  • Storage Temperature: -40-80 °C
  • Strip Length: 14 mm
  • Width: 36 mm
This Multi9 C60N is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 2A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. The weight is 0.24kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60N is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 2A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. The weight is 0.24kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Contact Position Indicator : yes
  • Line Rated Current : 2 A 50 °C EN/IEC 60947-2
  • Range Of Product : Multi 9
  • [Ics] Rated Service Breaking Capacity : 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC 50/60 Hz || 16 kA 75 % EN/IEC 60947-2 - 240 V AC 50/60 Hz || 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC 50/60 Hz || 20 kA 100 % EN/IEC 60947-2 - <= 125 V DC
  • Device Application : distribution
  • Range : Multi 9
  • Tropicalisation : 2 IEC 60068-1
  • Mechanical Durability : 20000 cycles
  • Local Signalling : ON/OFF indication
  • Mounting Support : DIN rail
  • Device Short Name : C60N
  • Net Weight : 0.24 kg
  • Standards : EN/IEC 60947-2
  • [Ui] Rated Insulation Voltage : 500 V AC 50/60 Hz EN/IEC 60947-2
  • Maximum Depth : 72 mm
  • Trip Unit Technology : thermal-magnetic
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2
  • Heat Dissipation : 5.2-5.2 W 415 V - 2 A
  • Product Or Component Type : miniature circuit-breaker
  • Network Frequency : 50/60 Hz
  • Poles Description : 2P
  • Curve Code : D
  • Suitability For Isolation : yes EN/IEC 60947-2
  • Breaking Capacity Code : N
  • Mounting Mode : clip-on
  • Relative Humidity : 95-95 % 55-55 °C
  • Utilisation Category : category A EN/IEC 60947-2
  • Color : Gray
  • Connections - Terminals : tunnel type terminal top or bottom) 1-25 mm² - rigid || tunnel type terminal top or bottom) 1-25 mm² - flexible || tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule
  • Product Certifications : EAC || KC || CCC
  • Provision For Padlocking : padlockable
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz between phases || 415 V AC 50/60 Hz between phases || 440 V AC 50/60 Hz between phases || <= 125 V DC
  • Ambient Air Temperature For Operation : -30-70 °C
  • Ambient Air Temperature For Storage : -40-80 °C
  • Magnetic Tripping Limit : 12 x In +/- 20 % AC || 17 x In +/- 20 % DC
  • Maximum Height : 81 mm
  • Overvoltage Category : IV
  • Maximum Width : 36 mm
  • Electrical Durability : 10000 cycles
  • Earth-Leakage Protection : separate block
  • Tightening Torque : 2-2 N.m top or bottom
  • Control Type : toggle
  • Breaking Capacity : 20 kA Icu <= 125 V DC EN/IEC 60947-2 || 10 kA Icu 415 V AC 50/60 Hz between phases EN/IEC 60947-2 || 20 kA Icu 240 V AC 50/60 Hz between phases EN/IEC 60947-2 || 6 kA Icu 440 V AC 50/60 Hz between phases EN/IEC 60947-2
  • Wire Stripping Length : 14 mm top or bottom
  • Number Of Protected Poles : 2
  • Product Name : Multi 9 C60
  • 9 Mm Pitches : 4
  • Limitation Class : 3
  • Network Type : AC || DC
  • Pollution Degree : 3 EN/IEC 60947-2