Multi9 - C60N - MCB - 1P - 25 A - D Curve - 240 V - 10 kA

Multi9 - C60N - MCB - 1P - 25 A - D Curve - 240 V - 10 kA

SQDM9F12125 M9F12125 360648057666
0.00 / EA
  • Certifications: CCC, EAC, KC
  • Depth: 72 mm
  • Height: 81 mm
  • Line Rated Current: 25 A, 50 °C
  • Net Weight: 0.12 kg
  • Operating Temperature: -30-70 °C
  • Standard: EN/IEC 60947-2
  • Storage Temperature: -40-80 °C
  • Strip Length: 14 mm
  • Width: 18 mm
This Multi9 C60N is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 25A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 72mm. The weight is 0.12kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60N is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 25A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 72mm. The weight is 0.12kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • 9 Mm Pitches : 2
  • Heat Dissipation : 3.1-3.1 W 240 V - 25 A
  • Relative Humidity : 95-95 % 55-55 °C
  • Curve Code : D
  • Line Rated Current : 25 A 50 °C EN/IEC 60947-2
  • Magnetic Tripping Limit : 12 x In +/- 20 % AC || 17 x In +/- 20 % DC
  • Suitability For Isolation : yes EN/IEC 60947-2
  • Device Application : distribution
  • Control Type : toggle
  • Tropicalisation : 2 IEC 60068-1
  • Product Or Component Type : miniature circuit-breaker
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz between phase and neutral || 415 V AC 50/60 Hz between phase and neutral || <= 72 V DC
  • [Ics] Rated Service Breaking Capacity : 7.5 kA 75 % EN/IEC 60947-2 - 240 V AC 50/60 Hz || 2.25 kA 75 % EN/IEC 60947-2 - 415 V AC 50/60 Hz || 15 kA 100 % EN/IEC 60947-2 - <= 72 V DC
  • Network Frequency : 50/60 Hz
  • Maximum Depth : 72 mm
  • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2
  • Network Type : AC || DC
  • Limitation Class : 3
  • Connections - Terminals : tunnel type terminal top or bottom) 1-25 mm² - rigid || tunnel type terminal top or bottom) 1-25 mm² - flexible || tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule
  • Local Signalling : ON/OFF indication
  • Maximum Height : 81 mm
  • Breaking Capacity Code : N
  • Maximum Width : 18 mm
  • Poles Description : 1P
  • Standards : EN/IEC 60947-2
  • Overvoltage Category : IV
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • Pollution Degree : 3 EN/IEC 60947-2
  • Provision For Padlocking : padlockable
  • Breaking Capacity : 15 kA Icu <= 72 V DC EN/IEC 60947-2 || 10 kA Icu 240 V AC 50/60 Hz between phase and neutral EN/IEC 60947-2 || 3 kA Icu 415 V AC 50/60 Hz between phase and neutral EN/IEC 60947-2
  • Net Weight : 0.12 kg
  • Ambient Air Temperature For Storage : -40-80 °C
  • Mechanical Durability : 20000 cycles
  • Electrical Durability : 10000 cycles
  • Utilisation Category : category A EN/IEC 60947-2
  • Wire Stripping Length : 14 mm top or bottom
  • Range Of Product : Multi 9
  • Mounting Mode : clip-on
  • Product Name : Multi 9 C60
  • Device Short Name : C60N
  • Ambient Air Temperature For Operation : -30-70 °C
  • Contact Position Indicator : yes
  • Mounting Support : DIN rail
  • [Ui] Rated Insulation Voltage : 500 V AC 50/60 Hz EN/IEC 60947-2
  • Product Certifications : EAC || KC || CCC
  • Trip Unit Technology : thermal-magnetic
  • Earth-Leakage Protection : separate block
  • Tightening Torque : 2-2 N.m top or bottom
  • Range : Multi 9
  • Color : Gray
  • Number Of Protected Poles : 1