Schneider Electric at Mayer

Miniature circuit breaker (MCB), Multi9 C60H, 2P, 6A, C curve, 15kA (IEC/EN 60947-2)

Miniature circuit breaker (MCB), Multi9 C60H, 2P, 6A, C curve, 15kA (IEC/EN 60947-2)

SQDM9F14206 M9F14206 3606480577178
304.27 / EA
http://schema.org/OutOfStock
This Multi9 C60H is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 6A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 15kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. The weight is 0.24kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
QTY
  • Product Description
  • Features
  • Specifications
This Multi9 C60H is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 6A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 15kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 72mm. The weight is 0.24kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Wire Stripping Length : 14 mm for top or bottom connection, 14 mm for top or bottom connection
    • Color : Gray
  • Conformance Attributes
    • Product Certifications : EAC, CCC
    • Standards : EN/IEC 60947-2
  • Complementary Attributes
    • Line Rated Current : 6 A 50 °C EN/IEC 60947-2, 6 A 50 °C EN/IEC 60947-2, 6 A 50 °C EN/IEC 60947-2
    • ICS Rated Service Breaking Capacity : 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC
    • UE Rated Operational Voltage : 240 V AC 50/60 Hz between phases, 240 V AC 50/60 Hz between phases, 240 V AC 50/60 Hz between phases, 240 V AC 50/60 Hz between phases, 415 V AC 50/60 Hz between phases, 415 V AC 50/60 Hz between phases, 415 V AC 50/60 Hz between phases, 415 V AC 50/60 Hz between phases, 440 V AC 50/60 Hz between phases, 440 V AC 50/60 Hz between phases, 440 V AC 50/60 Hz between phases, 440 V AC 50/60 Hz between phases, <= 125 V DC, <= 125 V DC
    • UI Rated Insulation Voltage : 500 V AC 50/60 Hz EN/IEC 60947-2, 500 V AC 50/60 Hz EN/IEC 60947-2, 500 V AC 50/60 Hz EN/IEC 60947-2, 500 V AC 50/60 Hz EN/IEC 60947-2
    • UIMP Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2, 6 kVEN/IEC 60947-2
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Connection Pitch : 18 mm between phases, 18 mm between phases
    • Heat Dissipation : 5.4-5.4 W 415 V - 6 A, 5.4-5.4 W 415 V - 6 A, 5.4-5.4 W 415 V - 6 A
    • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC, 8.5 x In +/- 20 % AC, 8.5 x In +/- 20 % AC, 12 x In +/- 20 % DC, 12 x In +/- 20 % DC, 12 x In +/- 20 % DC
    • Network Type : DC, AC
    • Suitability For Isolation : yes EN/IEC 60947-2, yes EN/IEC 60947-2
    • Tightening Torque : 2-2 N.m top or bottom, 2-2 N.m top or bottom
    • Tropicalisation : 2 IEC 60068-1, 2 IEC 60068-1
    • Utilisation Category : category A EN/IEC 60947-2, category A EN/IEC 60947-2
    • ICS Rated Service Breaking Capacity : 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 15 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 7.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 5 kA 50 % EN/IEC 60947-2 - 440 V AC 50/60 Hz, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC, 25 kA 100 % EN/IEC 60947-2 - <= 125 V DC
    • Carbon Footprint Of The Distribution Phase A4 : 0.031737500690295274, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.6368332170757884, 0.6 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.010298102999284759
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 1.5291666929887113
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 13 kg CO2 eq., 12.925846153846154
    • Connections Terminals : tunnel type terminal top or bottom) 1-25 mm² - rigid, tunnel type terminal top or bottom) 1-25 mm² - rigid, tunnel type terminal top or bottom) 1-25 mm² - rigid, tunnel type terminal top or bottom) 1-25 mm² - rigid, tunnel type terminal top or bottom) 1-25 mm² - flexible, tunnel type terminal top or bottom) 1-25 mm² - flexible, tunnel type terminal top or bottom) 1-25 mm² - flexible, tunnel type terminal top or bottom) 1-25 mm² - flexible, tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule, tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule, tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule, tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule
    • Auxiliaries : M9A26914, M9A26917
    • Local Data Status : Publishable
    • Local Publishable Date : 2024-02-10
    • HTML Description : Multi 9, C60H Miniature circuit-breaker, 2P, 6 A, C Curve, 415 V, 15 kA
    • Manufacturer : Schneider Electric
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • H And D Domain : Safety
    • H And D Subrange : Multi9 OEM MCB
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : MCB
    • H And D Enrichment Class 3 : Circuit Breakers
    • H And D Enrichment Class 4 : MCB IEC 2P
    • H And Dod Responsibility : Multi9
    • H And Dod Platform : MCB
    • Contact Position Indicator : yes
    • Curve Code : C
    • Device Short Name : C60H
    • Earth Leakage Protection : separate block
    • Electrical Durability : 10000 cycles
    • Energy Efficiency Optimized : False
    • Package Weight Lbs : 210 g
    • Power Losses Per Pole : 1.2 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : miniature circuit-breaker
    • Provision For Padlocking : padlockable
    • Range : Multi9
    • Range Of Product : Multi9
    • Returnability : No
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 15 kg CO2 eq.
    • Total Power Losses : 2.4 W
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Add Ons : M9V14263
    • Pep Code : ENVPEP1304004EN
    • Pep Verification Date : 2023-03-02
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : Protect during 20 years the installation against overloads and short-circuits in circuit with assigned voltage 240VAC and rated current 16A (In). This protection is ensured in accordance with the following parameters:& 10- Number of poles: 1& 10- Rated breaking capacity Icu: 10kA& 10- Tripping curve: C
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • IP Degree Of Protection : IP20 conforming to IEC 60529, IP20 conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529, IP40 (modular enclosure) conforming to IEC 60529
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 95-95 % 55-55 °C, 95-95 % 55-55 °C
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 15.218894129653878
    • 9 MM Pitches : 4
    • Ambient Air Temperature For Operation : -30-70 °C
    • Environmental Disclosure : ENVPEP1304004EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Pep Code : ENVPEP1304004EN
    • Pep Verification Date : 2023-03-02
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : Multi9