Schneider Electric at Mayer

Multi9 - C60H-DC - MCB - 2P - 40 A - D Curve - 500 V DC - 10 kA

Multi9 C60H-DC 40A K 500V-DC M

SQDM9U31240 M9U31240 785901778783
232.46 / EA
  • Amperage: 40 A
  • Certifications: CCC, IEC, UR
  • Country of Origin: China
  • Depth: 2.87 in, 73 mm
  • Height: 3.19 in, 81 mm
  • Mounting Type: Clip-On
  • Standard: EN/IEC 60947-2, GB 14048.2, UL 1077
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 220 V, 440 V, 500 V
  • Weight: 0.128 kg, 0.28 lb
  • Width: 1.42 in, 36 mm
This Multi9 C60H-DC is a low voltage miniature circuit breaker (MCB) dedicated to direct current. It is a 2P circuit breaker with 2 protected poles, 40A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VDC conforming to EN/IEC 60947-2 standard and 20kA at 220VDC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 73mm. The weight is 0.128kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
  • Product Description
  • Specifications
This Multi9 C60H-DC is a low voltage miniature circuit breaker (MCB) dedicated to direct current. It is a 2P circuit breaker with 2 protected poles, 40A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VDC conforming to EN/IEC 60947-2 standard and 20kA at 220VDC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 73mm. The weight is 0.128kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
  • Ordering And Shipping Details
    • Country Of Origin : CN
    • Nbr. Of Units In Pkg. : 1
    • GTIN : 00785901778783
    • Discount Schedule : DE2
    • Returnability : Yes
    • Category : 00948 - M9 GEN 2 CB UL1077 / IEC
  • Main
    • Number Of Protected Poles : 2
    • Suitability For ISOlation : Yes EN/IEC 60947-2
    • Network Type : DC
    • Product Certifications : IEC || CCC || UR
    • Curve Code : D
    • Product Or Component Type : Miniature circuit-breaker
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 1077
    • Poles Description : 2P
    • Trip Unit Technology : Thermal-magnetic
    • Range : Multi 9
    • Device Short Name : C60H-DC
    • Product Name : Multi 9 C60H-DC
    • In Rated Current : 40 A 77 °F (25 °C) EN/IEC 60947-2
    • Utilisation Category : Category A EN/IEC 60947-2
    • Breaking Capacity : 20 kA Icu 220 V DC EN/IEC 60947-2 || 10 kA Icu 440 V DC EN/IEC 60947-2 || 6 kA Icu 500 V DC EN/IEC 60947-2 || 5 kA AIR 12...500 V DC UL 1077 || 20 kA Icu 220 V DC GB 14048.2 || 10 kA Icu 440 V DC GB 14048.2 || 6 kA Icu 500 V DC GB 14048.2
    • Device Application : Distribution
  • Offer Sustainability
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • REACh Free Of SVHC : Yes
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • EU RoHs Directive : Compliant
  • Environment
    • Ambient Air Temp For Storage : -40…185 °F (-40…85 °C)
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Pollution Degree : 3 EN/IEC 60947-2
    • IP Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
    • Ambient Air Temp For Op : -13…158 °F (-25…70 °C)
    • Heat Dissipation : 8.6 W 440 V - 40 A
    • Tropicalisation : 2 IEC 60068-2 || 2 GB 14048.2
  • Complementary
    • Mounting Support : DIN rail
    • Mechanical Durability : 20000 cycles
    • 9 mm Pitches : 4
    • Depth : 2.87 in (73 mm)
    • Product Weight : 0.28 lb(US) (0.128 kg)
    • Height : 3.19 in (81 mm)
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • Electrical Durability : 3000 cycles 250 V DC L/R = 2 ms || 6000 cycles 250 V DC
    • Contact Position Indicator : Yes
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.05 in² (1…35 mm²) AWG 18...AWG 2) - rigid stranded || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 4) - flexible || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 4) - flexible with ferrule || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - rigid stranded || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - flexible || Tunnel type terminal top or bottom) - 2 0.00…0.02 in² (1…16 mm²) AWG 18...AWG 6) - flexible with ferrule || Tunnel type terminal top or bottom) - 3 0.01 in² (4 mm²) AWG 6) - flexible stranded
    • Ue Rated Operational Voltage : 220 V DC || 440 V DC || 500 V DC
    • Local Signalling : ON/OFF indication
    • Control Type : Toggle
    • Magnetic Tripping Limit : 10...14 x In DC
    • Width : 1.42 in (36 mm)
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • Provision For Padlocking : Padlockable
    • Ics Rated Service Breaking Cap : 7.5 kA 75 % EN/IEC 60947-2 - 440 V DC || 4.5 kA 75 % EN/IEC 60947-2 - 500 V DC || 15 kA 75 % EN/IEC 60947-2 - 220 V DC || 7.5 kA 75 % GB 14048.2 - 440 V DC || 4.5 kA 75 % GB 14048.2 - 500 V DC || 15 kA 75 % GB 14048.2 - 220 V DC
    • Mounting Mode : Clip-on
    • Earth-Leakage Protection : Without
    • Colour : Gray
    • Tightening Torque : 30.98 lbf.in (3.5 N.m) top or bottom
    • Ui Rated Insulation Voltage : 500 V DC EN/IEC 60947-2