Schneider Electric at Mayer

Multi 9 - C60BPR - MCB - 1P - 15 A - D Curve - 277 V - 10 kA - UL 489

Multi9 C60BPR 1P D 15A MCB

SQDM9F53115 M9F53115 785901134176
68.67 / EA
  • Amperage: 15 A
  • Certifications: CCC, CSA, IEC, UL
  • Country of Origin: France
  • Depth: 2.83 in, 72 mm
  • Height: 127 mm, 5 in
  • Mounting Type: Clip-On
  • Standard: CSA C22.2 No 5, EN/IEC 60947-2, GB 14048.2, UL 489
  • Voltage: 240 V, 415 V, 60 V
  • Width: 0.71 in, 18 mm
This Multi9 C60BPR is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 15A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 127mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60BPR is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 15A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 127mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Complementary
    • Mechanical Durability : 20000 cycles
    • Height : 5.00 in (127 mm)
    • Mounting Support : DIN rail
    • Magnetic Tripping Limit : 12 x In +/- 20 % AC || 17 x In +/- 20 % DC
    • Local Signalling : ON/OFF indication
    • Depth : 2.83 in (72 mm)
    • Width : 0.71 in (18 mm)
    • Provision For Padlocking : Padlockable
    • Connections - Terminals : Ring terminal top or bottom)
    • Control Type : Toggle
    • 9 mm Pitches : 2
    • Contact Position Indicator : Yes
    • Colour : Gray
    • Ui Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
    • Tightening Torque : 17.70 lbf.in (2 N.m) top or bottom
    • Earth-Leakage Protection : Without
    • Electrical Durability : 10000 cycles
    • Ics Rated Service Breaking Cap : 2.25 kA 75 % EN/IEC 60947-2 - 415 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 240 V AC || 2.25 kA 75 % GB 14048.2 - 415 V AC || 7.5 kA 75 % GB 14048.2 - 240 V AC || 15 kA 75 % GB 14048.2 - 60 V DC || 15 kA 75 % EN/IEC 60947-2 - 60 V DC
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • Mounting Mode : Clip-on
    • Ue Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 60 V DC
  • Environment
    • Pollution Degree : 3 EN/IEC 60947-2
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Ambient Air Temp For Op : -22…158 °F (-30…70 °C)
    • Tropicalisation : 2 IEC 60068-1
    • Relative Humidity : 95 % 131 °F (55 °C)
    • IP Degree Of Protection : IP20 conforming to IEC 60529 || IP40 modular enclosure)IEC 60529
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Overvoltage Category : IV
  • Ordering And Shipping Details
    • Discount Schedule : DE2
    • Country Of Origin : FR
    • Nbr. Of Units In Pkg. : 1
    • Category : 00949 - M9 GEN 2 CB UL489
    • GTIN : 00785901134176
    • Returnability : Yes
  • Offer Sustainability
    • EU RoHs Directive : Compliant
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Mercury Free : Yes
    • Green Premium Status : Green Premium product
    • Halogen Content Performance : Halogen free product
  • Main
    • Curve Code : D
    • Range : Multi 9
    • Device Short Name : C60BPR
    • Product Name : Multi 9 C60
    • Device Application : Distribution
    • Number Of Protected Poles : 1
    • In Rated Current : 15 A 77 °F (25 °C) EN/IEC 60947-2
    • Network Type : AC || DC
    • Suitability For ISOlation : Yes EN/IEC 60947-2
    • Poles Description : 1P
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5
    • Breaking Capacity : 3 kA Icu 415 V AC EN/IEC 60947-2 || 10 kA Icu 240 V AC EN/IEC 60947-2 || 20 kA Icu 60 V DC EN/IEC 60947-2 || 3 kA Icu 415 V AC GB 14048.2 || 10 kA Icu 240 V AC GB 14048.2 || 20 kA Icu 60 V DC GB 14048.2 || 10 kA AIR 277 V AC UL 489 || 14 kA AIR 240 V AC UL 489 || 14 kA AIR 120 V AC UL 489 || 10 kA AIR 60 V DC UL 489 || 10 kA AIR 277 V AC CSA C22.2 No 5 || 14 kA AIR 240 V AC CSA C22.2 No 5 || 14 kA AIR 120 V AC CSA C22.2 No 5 || 10 kA AIR 60 V DC CSA C22.2 No 5
    • Trip Unit Technology : Thermal-magnetic
    • Product Certifications : IEC || CCC || CSA || UL
    • Product Or Component Type : Miniature circuit-breaker