Multi 9 - C60BP - MCB - 2P - 45 A - C Curve - 240 V - 10 kA - UL 489

Multi9 C60BP 2P C 45A MCB

SQDM9F42245 M9F42245 785901713029
144.66 / EA
  • Certifications: CCC, CSA, IEC, UL
  • Depth: 72 mm
  • Height: 103 mm
  • Line Rated Current: 25 °C, 45 A
  • Mounting Type: Clip-On
  • Operating Temperature: -30-70 °C
  • Standard: CSA C22.2 No 5, EN/IEC 60947-2, GB 14048.2, UL 489
  • Storage Temperature: -40-80 °C
  • Strip Length: 14 mm
  • Width: 36 mm
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 45A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. The electrical endurance is up to 10000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 45A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. The electrical endurance is up to 10000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Ambient Air Temperature For Storage : -40-80 °C
  • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC
  • Maximum Width : 36 mm
  • Line Rated Current : 45 A 25 °C EN/IEC 60947-2
  • Connections - Terminals : tunnel type terminal top or bottom) 1-35 mm² AWG 18...AWG 2) - rigid || tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible with ferrule || tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible
  • Tightening Torque : 3.5-3.5 N.m top or bottom
  • Mounting Mode : clip-on
  • Trip Unit Technology : thermal-magnetic
  • Network Type : AC
  • Range : Multi 9
  • Range Of Product : Multi 9
  • Product Name : Multi 9 C60
  • Product Or Component Type : miniature circuit-breaker
  • Product Certifications : IEC || CCC || CSA || UL
  • Control Type : toggle
  • Mounting Support : DIN rail
  • Device Short Name : C60BP
  • Provision For Padlocking : padlockable
  • Contact Position Indicator : yes
  • Color : Gray
  • Ambient Air Temperature For Operation : -30-70 °C
  • Electrical Durability : 10000 cycles
  • Suitability For Isolation : yes EN/IEC 60947-2
  • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5
  • Earth-Leakage Protection : without
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
  • Operating Altitude : 0...6561.68 ft (0...2000 m)
  • Maximum Height : 103 mm
  • Number Of Protected Poles : 2
  • 9 Mm Pitches : 4
  • Local Signalling : ON/OFF indication
  • Wire Stripping Length : 14 mm top or bottom
  • Pollution Degree : 3 EN/IEC 60947-2
  • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2
  • Device Application : distribution
  • Maximum Depth : 72 mm
  • [Ics] Rated Service Breaking Capacity : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • Tropicalisation : 2 IEC 60068-1
  • Mechanical Durability : 20000 cycles
  • [Ui] Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
  • Breaking Capacity : 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2 || 10 kA AIR 240 V AC UL 489 || 10 kA AIR 240 V AC CSA C22.2 No 5
  • Curve Code : C
  • Poles Description : 2P
  • Relative Humidity : 95-95 % 55-55 °C