Schneider Electric at Mayer

Multi 9 - C60BP - MCB - 2P - 40 A - D Curve - 240 V - 10 kA - UL 489

MULTI9 C60BP 2P D 40A MCB

SQDM9F43240 M9F43240 785901713753
144.66 / EA
  • Amperage: 40 A
  • Certifications: CCC, CSA, IEC, UL
  • Country of Origin: France
  • Depth: 2.83 in, 72 mm
  • Height: 103 mm, 4.06 in
  • Mounting Type: Clip-On
  • Standard: CSA C22.2 No 5, EN/IEC 60947-2, GB 14048.2, UL 489
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 240 V, 415 V, 440 V
  • Width: 1.42 in, 36 mm
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 40A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 40A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Complementary
    • Control Type : Toggle
    • Mechanical Durability : 20000 cycles
    • Magnetic Tripping Limit : 12 x In +/- 20 % AC
    • Provision For Padlocking : Padlockable
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • Ui Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
    • Mounting Mode : Clip-on
    • Ue Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
    • Earth-Leakage Protection : Without
    • Mounting Support : DIN rail
    • Depth : 2.83 in (72 mm)
    • Width : 1.42 in (36 mm)
    • Contact Position Indicator : Yes
    • Tightening Torque : 30.98 lbf.in (3.5 N.m) top or bottom
    • Height : 4.06 in (103 mm)
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.05 in² (1…35 mm²) AWG 18...AWG 2) - rigid || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible with ferrule || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible
    • Electrical Durability : 10000 cycles
    • Colour : Gray
    • Ics Rated Service Breaking Cap : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
    • Local Signalling : ON/OFF indication
    • 9 mm Pitches : 4
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
  • Ordering And Shipping Details
    • Returnability : Yes
    • Country Of Origin : FR
    • Nbr. Of Units In Pkg. : 1
    • Discount Schedule : DE2
    • GTIN : 00785901713753
    • Category : 00949 - M9 GEN 2 CB UL489
  • Environment
    • Pollution Degree : 3 EN/IEC 60947-2
    • Ambient Air Temp For Op : -22…158 °F (-30…70 °C)
    • Tropicalisation : 2 IEC 60068-1
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • IP Degree Of Protection : IP20 conforming to IEC 60529 || IP40 modular enclosure)IEC 60529
    • Relative Humidity : 95 % 131 °F (55 °C)
  • Offer Sustainability
    • Halogen Content Performance : Halogen free product
    • Mercury Free : Yes
    • EU RoHs Directive : Compliant
    • Green Premium Status : Green Premium product
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • Main
    • Device Short Name : C60BP
    • Curve Code : D
    • Product Name : Multi 9 C60
    • Device Application : Distribution
    • In Rated Current : 40 A 77 °F (25 °C) EN/IEC 60947-2
    • Range : Multi 9
    • Number Of Protected Poles : 2
    • Suitability For ISOlation : Yes EN/IEC 60947-2
    • Network Type : AC
    • Product Certifications : IEC || CCC || CSA || UL
    • Trip Unit Technology : Thermal-magnetic
    • Product Or Component Type : Miniature circuit-breaker
    • Breaking Capacity : 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2 || 10 kA AIR 240 V AC UL 489 || 10 kA AIR 240 V AC CSA C22.2 No 5
    • Poles Description : 2P
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5