Multi 9 - C60BP - MCB - 2P - 30 A - C Curve - 480Y/277 V - 10 kA - UL 489

Multi 9 - C60BP - MCB - 2P - 30 A - C Curve - 480Y/277 V - 10 kA - UL 489

SQDM9F42230 M9F42230 785901701934
144.66 / EA
  • Amperage: 30 A
  • Certifications: CCC, CSA, IEC, UL
  • Country of Origin: France
  • Depth: 2.83 in, 72 mm
  • Height: 103 mm, 4.06 in
  • Mounting Type: Clip-On
  • Standard: CSA C22.2 No 5, EN/IEC 60947-2, GB 14048.2, UL 489
  • Strip Length: 0.55 in, 14 mm
  • Voltage: 240 V, 415 V, 440 V
  • Width: 1.42 in, 36 mm
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 30A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 30A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Environment
    • Ambient Air Temp For Storage : -40…176 °F (-40…80 °C)
    • Ambient Air Temp For Op : -22…158 °F (-30…70 °C)
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Tropicalisation : 2 conforming to IEC 60068-1
    • IP Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
    • Relative Humidity : 95 % 131 °F (55 °C)
    • Pollution Degree : 3 EN/IEC 60947-2
  • Main
    • Network Type : DC || AC
    • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5
    • Breaking Capacity : 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2 || 14 kA AIR 240 V AC UL 489 || 10 kA AIR 125 V DC UL 489 || 10 kA AIR 480Y/277 V AC UL 489 || 14 kA AIR 240 V AC CSA C22.2 No 5 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 5 || 10 kA AIR 125 V DC CSA C22.2 No 5
    • In Rated Current : 30 A 77 °F (25 °C) EN/IEC 60947-2
    • Curve Code : C
    • Product Or Component Type : Miniature circuit-breaker
    • Device Application : Distribution
    • Poles Description : 2P
    • Range : Multi 9
    • Product Certifications : IEC || CCC || CSA || UL
    • Number Of Protected Poles : 2
    • Device Short Name : C60BP
    • Product Name : Multi 9 C60
    • Suitability For ISOlation : Yes EN/IEC 60947-2
    • Trip Unit Technology : Thermal-magnetic
  • Ordering And Shipping Details
    • Nbr. Of Units In Pkg. : 1
    • Returnability : Yes
    • Category : 00949 - M9 GEN 2 CB UL489
    • Discount Schedule : DE2
    • Country Of Origin : FR
    • GTIN : 00785901701934
  • Offer Sustainability
    • EU RoHs Directive : Compliant
    • Mercury Free : Yes
    • WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Green Premium Status : Green Premium product
    • Halogen Content Performance : Halogen free product
  • Complementary
    • Local Signalling : ON/OFF indication
    • Mounting Mode : Clip-on
    • Mounting Support : DIN rail
    • Depth : 2.83 in (72 mm)
    • Electrical Durability : 10000 cycles
    • Ics Rated Service Breaking Cap : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
    • Wire Stripping Length : 0.55 in (14 mm) top or bottom
    • 9 mm Pitches : 4
    • Width : 1.42 in (36 mm)
    • Height : 4.06 in (103 mm)
    • Earth-Leakage Protection : Without
    • Tightening Torque : 30.98 lbf.in (3.5 N.m) top or bottom
    • Control Type : Toggle
    • Ui Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
    • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC || 12 x In +/- 20 % DC
    • Colour : Gray
    • Provision For Padlocking : Padlockable
    • Connections - Terminals : Tunnel type terminal top or bottom) 0.00…0.05 in² (1…35 mm²) AWG 18...AWG 2) - rigid || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible with ferrule || Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) AWG 18...AWG 3) - flexible
    • Mechanical Durability : 20000 cycles
    • Uimp Rated Imp Wstd Voltage : 6 kVEN/IEC 60947-2
    • Ue Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
    • Contact Position Indicator : Yes