Multi 9 - C60BP - MCB - 2P - 25 A - C Curve - 480Y/277 V - 10 kA - UL 489

MULTI9 C60BP 2P C 25A MCB

SQDM9F42225 M9F42225 785901706083
138.46 / EA
  • Certifications: CCC, CSA, IEC, UL
  • Depth: 72 mm
  • Height: 103 mm
  • Line Rated Current: 25 °C, 25 A
  • Mounting Type: Clip-On
  • Operating Temperature: -30-70 °C
  • Standard: CSA C22.2 No 5, EN/IEC 60947-2, GB 14048.2, UL 489
  • Storage Temperature: -40-80 °C
  • Strip Length: 14 mm
  • Width: 36 mm
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 25A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 25A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Range : Multi 9
  • Wire Stripping Length : 14 mm top or bottom
  • Magnetic Tripping Limit : 8.5 x In +/- 20 % AC || 12 x In +/- 20 % DC
  • Mounting Mode : clip-on
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
  • [Ui] Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
  • [Ics] Rated Service Breaking Capacity : 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
  • Maximum Width : 36 mm
  • Suitability For Isolation : yes EN/IEC 60947-2
  • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2
  • Pollution Degree : 3 EN/IEC 60947-2
  • Tropicalisation : 2 IEC 60068-1
  • Trip Unit Technology : thermal-magnetic
  • Tightening Torque : 2.5-2.5 N.m top or bottom
  • Breaking Capacity : 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2 || 14 kA AIR 240 V AC UL 489 || 10 kA AIR 125 V DC UL 489 || 10 kA AIR 480Y/277 V AC UL 489 || 14 kA AIR 240 V AC CSA C22.2 No 5 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 5 || 10 kA AIR 125 V DC CSA C22.2 No 5
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • Range Of Product : Multi 9
  • Device Application : distribution
  • Curve Code : C
  • Ambient Air Temperature For Operation : -30-70 °C
  • Line Rated Current : 25 A 25 °C EN/IEC 60947-2
  • Network Type : AC || DC
  • Electrical Durability : 10000 cycles
  • Maximum Depth : 72 mm
  • Control Type : toggle
  • Relative Humidity : 95-95 % 55-55 °C
  • Connections - Terminals : tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 8) - rigid || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible with ferrule || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible
  • Ambient Air Temperature For Storage : -40-80 °C
  • Color : Gray
  • Device Short Name : C60BP
  • Poles Description : 2P
  • Local Signalling : ON/OFF indication
  • 9 Mm Pitches : 4
  • Mechanical Durability : 20000 cycles
  • Mounting Support : DIN rail
  • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5
  • Maximum Height : 103 mm
  • Provision For Padlocking : padlockable
  • Product Name : Multi 9 C60
  • Earth-Leakage Protection : without
  • Product Certifications : IEC || CCC || CSA || UL
  • Product Or Component Type : miniature circuit-breaker
  • Number Of Protected Poles : 2
  • Operating Altitude : 0...6561.68 ft (0...2000 m)
  • Contact Position Indicator : yes