Schneider Electric at Mayer

Multi 9 - C60BP - MCB - 1P - 3 A - D Curve - 277 V - 10 kA - UL 489

Multi9 C60BP 1P D 3A MCB

SQDM9F43103 M9F43103 785901686194
70.36 / EA
  • Certifications: CCC, CSA, IEC, UL
  • Depth: 72 mm
  • Height: 103 mm
  • Line Rated Current: 25 °C, 3 A
  • Mounting Type: Clip-On
  • Operating Temperature: -30-70 °C
  • Standard: CSA C22.2 No 5, EN/IEC 60947-2, GB 14048.2, UL 489
  • Storage Temperature: -40-80 °C
  • Strip Length: 14 mm
  • Width: 18 mm
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 3A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • Product Description
  • Specifications
This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 3A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
  • 9 Mm Pitches : 2
  • Product Certifications : IEC || CCC || CSA || UL
  • Product Or Component Type : miniature circuit-breaker
  • Electrical Durability : 10000 cycles
  • Mechanical Durability : 20000 cycles
  • Ip Degree Of Protection : IP20IEC 60529 || IP40 modular enclosure)IEC 60529
  • Tightening Torque : 2.5-2.5 N.m top or bottom
  • Relative Humidity : 95-95 % 55-55 °C
  • [Ui] Rated Insulation Voltage : 500 V AC EN/IEC 60947-2
  • Earth-Leakage Protection : without
  • Mounting Support : DIN rail
  • Device Application : distribution
  • [Ics] Rated Service Breaking Capacity : 2.25 kA 75 % EN/IEC 60947-2 - 415 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 240 V AC || 2.25 kA 75 % GB 14048.2 - 415 V AC || 7.5 kA 75 % GB 14048.2 - 240 V AC || 15 kA 75 % GB 14048.2 - 60 V DC || 15 kA 75 % EN/IEC 60947-2 - 60 V DC
  • Number Of Protected Poles : 1
  • [Uimp] Rated Impulse Withstand Voltage : 6 kVEN/IEC 60947-2
  • Maximum Depth : 72 mm
  • [Ue] Rated Operational Voltage : 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 60 V DC
  • Ambient Air Temperature For Storage : -40-80 °C
  • Control Type : toggle
  • Product Name : Multi 9 C60
  • Standards : EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5
  • Connections - Terminals : tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 8) - rigid || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible with ferrule || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible
  • Mounting Mode : clip-on
  • Curve Code : D
  • Trip Unit Technology : thermal-magnetic
  • Local Signalling : ON/OFF indication
  • Maximum Height : 103 mm
  • Device Short Name : C60BP
  • Wire Stripping Length : 14 mm top or bottom
  • Provision For Padlocking : padlockable
  • Maximum Width : 18 mm
  • Suitability For Isolation : yes EN/IEC 60947-2
  • Network Type : DC || AC
  • Range : Multi 9
  • Contact Position Indicator : yes
  • Pollution Degree : 3 EN/IEC 60947-2
  • Line Rated Current : 3 A 25 °C EN/IEC 60947-2
  • Tropicalisation : 2 IEC 60068-1
  • Ambient Air Temperature For Operation : -30-70 °C
  • Magnetic Tripping Limit : 12 x In +/- 20 % AC || 17 x In +/- 20 % DC
  • Range Of Product : Multi 9
  • Color : Gray
  • Operating Altitude : 0...6561.68 ft (0...2000 m)
  • Poles Description : 1P
  • Breaking Capacity : 3 kA Icu 415 V AC EN/IEC 60947-2 || 10 kA Icu 240 V AC EN/IEC 60947-2 || 20 kA Icu 60 V DC EN/IEC 60947-2 || 3 kA Icu 415 V AC GB 14048.2 || 10 kA Icu 240 V AC GB 14048.2 || 20 kA Icu 60 V DC GB 14048.2 || 10 kA AIR 277 V AC UL 489 || 14 kA AIR 240 V AC UL 489 || 14 kA AIR 120 V AC UL 489 || 10 kA AIR 60 V DC UL 489 || 10 kA AIR 277 V AC CSA C22.2 No 5 || 14 kA AIR 240 V AC CSA C22.2 No 5 || 14 kA AIR 120 V AC CSA C22.2 No 5 || 10 kA AIR 60 V DC CSA C22.2 No 5