Schneider Electric at Mayer

modular discovery packs, Zelio Logic SR2 SR3, smart relay discovery pack, 26 IO, 100 to 240V AC

Zelio SR3PACK Modular 26 I-O 1

SQDSR3PACK2FU SR3PACK2FU 3389110550054
584.61 / EA
http://schema.org/OutOfStock
  • Certifications: CSA, C-tick, GL, GOST, UL
  • Net Weight: 0.85 kg
  • Number of Outputs: 10
  • Standard: IEC 60068-2-27 Ea, IEC 60068-2-6 Fc, IEC 61000-4-11, IEC 61000-4-12, IEC 61000-4-2 Level 3, IEC 61000-4-3, IEC 61000-4-4 Level 3, IEC 61000-4-5, IEC 61000-4-6 Level 3
  • Storage Temperature: -40-70 °C
  • Warranty Length: 18 mth
This Zelio Logic SR3 discovery pack compact smart relay / programmable controller uses a supply voltage of 100V to 240V alternating current. It has 26 inputs / outputs with screw-clamp terminals and has an integrated LCD display. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. This discovery package includes one copy of Zelio Soft and one USB cable to connect the relay to your PC. Its simple ladder programming makes it adapted for non-specialists.
QTY
  • Product Description
  • Specifications
This Zelio Logic SR3 discovery pack compact smart relay / programmable controller uses a supply voltage of 100V to 240V alternating current. It has 26 inputs / outputs with screw-clamp terminals and has an integrated LCD display. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. This discovery package includes one copy of Zelio Soft and one USB cable to connect the relay to your PC. Its simple ladder programming makes it adapted for non-specialists.
  • Environment
    • Product Certifications : GL || UL || C-tick || CSA || GOST
    • Standards : IEC 61000-4-5 || IEC 61000-4-2 level 3 || IEC 60068-2-27 Ea || IEC 61000-4-3 || IEC 60068-2-6 Fc || IEC 61000-4-6 level 3 || IEC 61000-4-11 || IEC 61000-4-4 level 3 || IEC 61000-4-12
    • Disturbance Radiated/Conducted : class B EN 55022-11 group 1
    • Ambient Air Temperature For Operation : -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
    • Immunity To Microbreaks : 10 ms
    • Environmental Characteristic : EMC directive IEC 61000-6-2 || EMC directive IEC 61000-6-3 || EMC directive IEC 61000-6-4 || EMC directive IEC 61131-2 zone B || low voltage directive IEC 61131-2
    • Ip Degree Of Protection : IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
    • Pollution Degree : 2 IEC 61131-2
    • Ambient Air Temperature For Storage : -40-70 °C
    • Relative Humidity : 95-95 % without condensation or dripping water
    • Maximum Altitude Transport : 3048 m
    • Operating Altitude : 6561.68 ft (2000 m)
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP060406EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI0604006EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • Contacts Type And Composition : NO relay output
    • Input Impedance : 350 kOhm discrete input
    • Discrete Input Frequency : 47...53 Hz || 57...63 Hz
    • Output Thermal Current : 5 A for 2 outputs relay output || 8 A for 8 outputs relay output
    • Number Or Control Scheme Lines : 120-120 ladder || 0-200 FBD
    • Discrete Input Voltage : 100...240 V AC
    • Backup Time : 10 years 25 °C
    • Clock Drift : 12 min/year 0-55 °C || 6 s/month 25-25 °C
    • Power Consumption In Va : 12 VA without extension || 17 VA with extensions
    • Discrete Input Current : 0.6 mA
    • Current State 1 Guaranteed : >= 0.17 mA discrete input)
    • Response Time : 50 ms ladder from state 0 to state 1)discrete input || 50 ms ladder from state 1 to state 0)discrete input || 50...255 ms FBD from state 0 to state 1)discrete input || 50...255 ms FBD from state 1 to state 0)discrete input || 10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
    • Clock : with
    • Local Display : with
    • Net Weight : 0.85 kg
    • Input/Output Number : 26
    • Voltage State 0 Guaranteed : <= 40 V discrete input
    • Output Voltage Limits : 5...30 V DC relay output) || 24...250 V AC
    • Electrical Durability : AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1
    • Connections - Terminals : screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid || screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid || screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end
    • Voltage State 1 Guaranteed : >= 79 V discrete input
    • Current State 0 Guaranteed : <= 0.5 mA discrete input)
    • Supply Voltage Limits : 85-264 V
    • Overvoltage Category : III IEC 60664-1
    • Mechanical Durability : 10000000 cycles relay output
    • Maximum Supply Current : 100 mA 100 V without extension) || 50 mA 240 V without extension) || 60 mA 240 V with extensions) || 80 mA 100 V with extensions)
    • Tightening Torque : 0.5 N.m
    • Isolation Voltage : 1780 V
    • Switching Capacity In Ma : >= 10 mA 12 V relay output)
    • Protection Type : against inversion of terminals (control instructions not executed)
    • [Uimp] Rated Impulse Withstand Voltage : 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    • Operating Rate In Hz : 0.1 Hz at Ie)relay output || 10 Hz no load)relay output
    • Cycle Time : 6-90 ms
    • Kit Composition : cable PC SR2USB01 for connection to PC || SR3B261FU
    • Supply Frequency : 50/60 Hz
    • [Us] Rated Supply Voltage : 100...240 V
    • Checks : program memory on each power up
  • Specifications
    • Range Of Product : Zelio Logic
    • Number Of Outputs : 10 relay
    • Product Or Component Type : modular discovery packs
    • Discrete Input Number : 16