Schneider Electric at Mayer

Safety module, Modicon TM3 Safety, 2 Function, Cat 3 PL d/SIL CL2 (spring) 24 VDC

MODULE TM3 SAFETY ES SLB, SPR

SQDTM3SAFL5RG TM3SAFL5RG 3606485393025
412.09 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 73 mm
  • Output Voltage: 10 V
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The safety module provides 3 normally opened contacts and unlimited synchronisation time between inputs. It is a safety module with a rated supply voltage of 24V DC, an external supply current consumption of 100mA at 24V DC on power supply and a power consumption 0.2W at 5V DC, 3.6W at 24V DC. The main functions of this module are emergency stop, movable guard, multiple emergency stop, proximity sensor and electro-sensitive protection equipment (ESPE) monitoring. It is furnished with spring terminal for electrical connection. It is an IP20 rated product. Its dimensions are 43.7mm (Width) x 73mm (Depth) x 94mm (Height). It weighs 0.19kg. It is suitable for emergency stop, switch and safety light curtain monitoring applications. This product is certified by RCM, CSA, UL, TÜV, ANSI Haz Loc Class 1 Division 2, EAC. It supports wall mount using attached fasteners. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : CSA 61010-2-201 (pending), RCM, UL 61010-2-201, EAC, ANSI Haz Loc Class 1 Division 2 (pending), CSA Haz Loc Class 1 Division 2 (pending), TÜV
    • Standards : ISO 13849-1:2008, ISO 13849-2:2012, IEC 62061:2005, IEC 61508:2010, IEC 60947-5-1:2010, IEC 61131-2:2007, IEC 60204-1:2005, IEC 60204-1:2009/A1, IEC 61010-1:2010, EN 50581:2012, IEC 60204-1, EN 1088/ISO 14119, ISO 13850, IEC 60947-1, IEC 60947-5-1
  • Complementary Attributes
    • Maximum Switching Voltage : 230 V AC-15 50 Hz relay instantaneous opening), 24 V DC-13 relay instantaneous opening)
    • Maximum Cable Distance Between Devices : 30 m
    • Maximum Response Time On Input Open : 40 ms
    • Minimum Output Current : 10 mA relay output
    • Uc Control Circuit Voltage : 24 V DC
    • Ui Rated Insulation Voltage : 300 V 2)IEC 60647-5-1
    • Uimp Rated Impulse Withstand Voltage : 4 kV III IEC 60647-5-1
    • Us Rated Supply Voltage : 24 V - 15...20 % DC
  • Important Information Attributes
    • Associated Fuse Rating : 4 A gG or gL relay output IEC 60947-5-1, 6 A fast blow relay output IEC 60947-5-1
    • Electromagnetic Compatibility : electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2, electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2, susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3, susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3, magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4, electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4, 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5, conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6, radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011, radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
    • Electromagnetic Emission : radiated emissions 50 dBµV/m class A 24 V DC)30-230 Hz IEC 61131-3, radiated emissions 57 dBµV/m class A 24 V DC)230-1000 Hz IEC 61131-3
    • Function Of Module : emergency stop monitoring 2-channel wiring, monitoring of a movable guard with 2 switches and automatic start, monitoring of a movable guard, multiple emergency stop monitoring 2-channel wiring, proximity sensor monitoring PNP/PNP, monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP
    • Marking : RCM, UL, CSA, EAC, CE, TÜV, EFUP 10
    • Mounting Support : top hat type TH35-7.5 rail IEC 60715, top hat type TH35-15 rail IEC 60715, wall mount using attached fasteners
    • Power Consumption In W : 0.2 W 5 V DC, 3.6 W 24 V DC
    • Resistance To Electromagnetic Fields : 10 V/m 80 MHz...1 GHz IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3, 1 V/m 2 GHz...3 GHz IEC 61000-4-3
    • Resistance To Electrostatic Discharge : 8 kV in air IEC 61000-4-2, 6 kV on contact IEC 61000-4-2
    • Resistance To Fast Transients : 3 kV power lines (DC) DC)IEC 61000-4-4, 2 kV I/O linesIEC 61000-4-4
    • Safety Level : can reach PL d/category 3 ISO 13849-1 2008, can reach PL d/category 3 ISO 13849-2 2012, can reach SILCL 2 IEC 62061 2005, can reach SIL 2 IEC 61508 2010
    • Safety Reliability Data : DC = 95 % ISO 13849-1, PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A, PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A, MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A, MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A, SFF = 95 % IEC 61508-1, HFT = 1 IEC 61508-1, type = A IEC 61508-1
    • Vibration Resistance : +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6, +/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6
    • Connections Terminals : captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals, captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34, captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals, captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals, captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
    • Carbon Footprint Of The Distribution Phase A4 : 0.033803965, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.2 kg CO2 eq., 0.1556858144
    • Carbon Footprint Of The Installation Phase A5 : 0.0004498416, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 4 kg CO2 eq., 3.8426360771
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 155 kg CO2 eq., 154.51
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Use Carbon Footprint : 154.51
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1403010EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1845
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Current Consumption : 100 mA 24 V DC external supply
    • Device Short Name : TM3SAFL
    • Electrical Connection : spring terminal
    • Local Signalling : 8 LEDs (green/red) for user
    • Mechanical Robustness : bumps 6 ms 300 shocks 25 gn) IEC 60068-2-27
    • Number Of Safety Circuits : 3 NO relay instantaneous opening
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : safety module
    • Range Of Product : Modicon TM3 Safety
    • Resistance To Conducted Disturbances : 10 V 0.15...80 MHz IEC 61000-4-6
    • Resistance To Magnetic Fields : 30 A/m 50/60 Hz IEC 61000-4-8
    • Returnability : No
    • Safety Module Application : for emergency stop, switch and safety light curtain monitoring
    • Shock Resistance : 15 gn 11 ms IEC 60068-2-27
    • Software Version : EIME v5.7.0.4
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 159 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 18 A
    • Warranty In Months : 18
    • Pep Code : ENVPEP1403010EN
    • Database Version : 2016-11
    • Pep Verification Date : 2018-11-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : to enhance safety related functionality of the M221, M41 and M251 controllers 100% of the time for 10 years at 3.6W
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unité (unit)
    • Product Weight In G2 : 262
    • Reference Lifetime In Y2 : 10
    • Energy Consumption On Product Lifetime In Kwh : 315.36
    • Energy Model Manufacturing A1 A3 2 : Energy model used: Germany
    • Energy Model Installation A5 2 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model Use B6 2 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity mix; AC; < 1kV; EU-27
    • Offer Owner Code : 190786
    • Height Nominal : 94 mm
    • Width Nominal : 43.7 mm
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 2 : 1753.8
    • Net Use Of Fresh Water M3 Operational Energy Use B6 2 : 560.23
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 2 : 576.08
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 2693.5
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 2 : 3085.9
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 392.4
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 2693.5
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 392.4
    • Air Pollution M3 Operational Energy Use B6 2 : 6650.1
    • Water Pollution M3 Operational Energy Use B6 2 : 6375.6
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 2 : 0.6445
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 2 : 154.51
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -10-55 °C horizontal installation, -10-55 °C horizontal installation, -10-55 °C horizontal installation, -10-55 °C horizontal installation
    • Relative Humidity : 10-95 %, without condensation in operation), 10-95 %, without condensation in storage)
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 158.542575698
    • Ambient Air Temperature For Storage : -25-70 °C
    • Circularity Profile : ENVEOLI1403010EN
    • Environmental Disclosure : ENVPEP1403010EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 terminals)IEC 60529
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Product Compatibility : safety light curtains EN/IEC 61496-1 (type 4)
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Storage Altitude : 0-3000 m
    • Pep Code : ENVPEP1403010EN
    • Pep Verification Date : 2018-11-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : safety module
    • Range Of Product : Modicon TM3 Safety
  • ETIM
    • ETIM 8 : EC001449
    • ETIM 9 : EC001449
  • Output Attributes
    • Minimum Output Current : 10 mA relay output
    • Output Thermal Current : 6 A per relay relay output
    • Output Type : relay instantaneous opening, 3 NO, potential free
    • Output Voltage : 10 V relay output
  • Surge Protection And Filtering Attributes
    • Surge Withstand : 1 kV power lines (DC) differential mode IEC 61000-4-5 DC, 1 kV power lines (DC) common mode IEC 61000-4-5 DC
  • Input Attributes
    • Input Protection Type : internal, electronic
    • Maximum Response Time On Input Open : 40 ms
    • Synchronisation Time Between Inputs : unlimited
  • Specifications
    • Country of Origin : United States
    • Depth : 73 mm