"This Harmony RXM miniature plug-in relay has a coil control voltage of 48V DC and has 2 changeover contacts DPDT (double pole double throw) with a rating of 12A." "It has large choice of number of contacts for high rated current use with space-saving de
QTY
  • Product Description
  • Features
  • Specifications
"This Harmony RXM miniature plug-in relay has a coil control voltage of 48V DC and has 2 changeover contacts DPDT (double pole double throw) with a rating of 12A." "It has large choice of number of contacts for high rated current use with space-saving de
  • IE Rated Operational Current
    • 12 A 28 V DC) NO IEC
    • 12 A 250 V AC) NO IEC
    • 6 A 28 V DC) NC IEC
  • Test Levels
    • level A group mounting
  • IP Degree Of Protection
    • IP40 conforming to IEC 60529
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproduc
  • Carbon Footprint Of The Installation Phase A5
    • 0.0002140314
    • 0 kg CO2 eq.
  • Load Current
    • 12 A 250 V AC
    • 12 A 28 V DC
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0 kg CO2 eq.
    • 0.0045783488
  • Maximum Switching Voltage
    • 250 V IEC
  • UC Control Circuit Voltage
    • 48 V DC
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 0.3 kg CO2 eq.
    • 0.2769140373
  • UI Rated Insulation Voltage
    • 250 V IEC
    • 300 V CSA
    • 300 V UL
  • Electrical Durability
    • 100000 cycles resistive
  • Vibration Resistance
    • 3 gn +/- 1 mm 10-150 Hz)5 cycles in operation
    • 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating
    • 5 gn +/- 1 mm 10-150 Hz
  • Market Segmentation
    • Commercial
    • Industrial
  • Rated Operational Voltage Limits
    • 38.4...52.8 V DC
  • Persona Type Names
    • Charge Point Operator
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
    • System Integrator
    • IT Channel Partner
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 15 kg CO2 eq.
    • 14.6907796747
  • Persona Type Ids
    • BM9
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
    • SI
    • VR
  • Dielectric Strength
    • 1300 V AC between contacts with micro disconnection
    • 2000 V AC between coil and contact with basic
  • Carbon Footprint Of The Distribution Phase A4
    • 0.0045157932
    • 0 kg CO2 eq.
  • Average Resistance
    • 2560 Ohm 20 °C +/- 10 %
  • Minimum Switching Capacity
    • 170 mW 10 mA, 17 V
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Operating Rate
    • <= 1200 cycles/hour under load
    • <= 18000 cycles/hour no-load
  • Shock Resistance
    • 10 gnin operation
    • 30 gnnot operating
  • UIMP Rated Impulse Withstand Voltage
    • 4 kV 1.2/50 µs
  • Complementary Attributes
    • Maximum Switching Capacity : 3000 VA/336 W
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Manufacturing Carbon Footprint : 0.2769140373
    • Distribution Carbon Footprint : 0.0045157932
    • Installation Carbon Footprint : 0.0002140314
    • Use Carbon Footprint : 14.6907796747
    • End Of Life Carbon Footprint : 0.0045783488
    • Legacy WEEE Scope : Out
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2106019EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant
    • ROHS EUR Conformity Date : 1930
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • China ROHS Label : 1
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Coil Consumption : 0.9 W
    • Compatibility Code : RXM
    • Drop Out Voltage Threshold : >= 0.1 Uc
    • Operating Time : 20 ms
    • Package Weight Lbs : 35.000 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : plug-in relay
    • Protection Category : RT I
    • Range Of Product : Harmony Electromechanical Relays
    • Returnability : Yes
    • Series Name : RXM series
    • Shape Of Pin : flat (faston type)
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 15 kg CO2 eq.
    • Utilisation Coefficient : 20 %
    • ITHE Conventional Enclosed Thermal Current : 12 A
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 14.9770018854
    • Pep Code : ENVPEP2106019EN
    • Pep Verification Date : 2021-12-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 35
    • Functional Unit Description : RXM.AB Miniature plug-in relay is to control a circuit by a low-power signal with complete electrical isolation between control and controlled circuits or where several circuits must be controlled by one signal .This range consists of RXM2AB, RXM3AB, RXM
    • Functional Unit Quantity : 1
    • Functional Unit Unit : Unit
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 21.21742
    • Energy Model Manufacturing A1 A3 : Energy model used: China
    • Energy Model Installation A5 : Electricity mix; AC; 120V; US
    • Energy Model Use B6 : Electricity mix; AC; 120V; US
    • Energy Model End Of Life C1 C4 : Electricity mix; AC; 120V; US
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0004009137
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.000400769
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000002
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000001444
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000001
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 181.8817575752
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 2.9175701523
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.0634427596
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.0027747334
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 178.8619509703
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.0360189597
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.0000125023
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0000011752
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.0000113271
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 3.1966478562
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 2.7592450548
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000000105
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.3927835086
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0446192822
    • Materials For Energy Recovery Kg Total Life Cycle : 0.0005623122
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.0005623122
    • Materials For Recycling Kg Total Life Cycle : 0.0240057848
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.0034020966
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.0039348089
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.0166688793
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.0339944074
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.0080260499
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000004041
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000000234
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.0259638316
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0000040984
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 2.3540527337
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.107506183
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0001604418
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0000290518
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 2.2462196067
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0001374503
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000002892
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000000225
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000002664
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000002
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.000311569
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0000801142
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000001143
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000000057
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.0002311183
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000002165
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 189.9228841623
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.9169112839
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0637645725
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.002790824
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 185.8946329909
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.044784491
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 202.0351159249
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 4.1521617276
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 0.0638497583
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.0027952124
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 197.7714748288
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.0448343978
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 12.1130793136
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.2352332345
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0000850911
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0000043412
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 11.8777068664
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0000497803
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.3466889404
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.3466889404
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 189.5762038266
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.5702309481
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0637645725
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.002790824
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 185.8946329909
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.044784491
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.0785671087
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.0785671087
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 12.034510484
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.1566644049
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0000850911
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0000043412
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 11.8777068664
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0000497803
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0018206526
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0018206526
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 1323.9263812012
    • Air Pollution M3 Manufacturing A1 A3 : 75.8583727917
    • Air Pollution M3 Distribution A4 : 0.1920982501
    • Air Pollution M3 Installation A5 : 0.00853596
    • Air Pollution M3 Operational Energy Use B6 : 1247.5441586758
    • Air Pollution M3 End Of Life C1 C4 : 0.3232155237
    • Water Pollution M3 Total Life Cycle : 775.8331941409
    • Water Pollution M3 Manufacturing A1 A3 : 50.4299853967
    • Water Pollution M3 Distribution A4 : 0.7426135442
    • Water Pollution M3 Installation A5 : 0.0324592264
    • Water Pollution M3 Operational Energy Use B6 : 724.245144121
    • Water Pollution M3 End Of Life C1 C4 : 0.3829918526
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 0.0152168086
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.0023428291
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.0038881379
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.0011207524
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.0000206184
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.0000008918
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 0.014065364
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.000009182
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 14.9770018854
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 0.2769140373
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.0045157932
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.0002140314
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 14.6907796747
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.0045783488
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.0000873628
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.0000014713
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.0000000667
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.0022529668
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.0000009616
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.0001738478
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.000004749
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0000002167
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.0037068203
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.000002504
    • Warranty In Months : 18
  • General Attributes
    • Product Or Component Type : plug-in relay
    • Range Of Product : Harmony Electromechanical Relays
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=649578&lang=en-us
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 14.9770018854
    • Ambient Air Temperature For Operation : -40-55 °C
    • Circularity Profile : ENVEOLI2106019EN
    • Environmental Disclosure : ENVPEP2106019EN
    • EU ROHS Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2106019EN
    • Pep Verification Date : 2021-12-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : China
  • Overview Attributes
    • Device Presentation : complete product