Schneider Electric at Mayer

miniature plug in relay, Harmony Electromechanical Relays, 10A, 3CO, with LED, lockable test but to n, 110V DC

PLUG-IN RELAY 250V 10A RXM +OP

SQDRXM3AB2FD RXM3AB2FD 3389119403672
11.59 / EA
http://schema.org/OutOfStock
  • Dielectric Strength: 1300 V, 2000 V
  • Operating Position: Any Position
  • Warranty Length: 18 mth
"This Harmony RXM miniature plug-in relay has a coil control voltage of 110V DC and has 3 changeover contacts 3PDT (triple pole double throw) with a rating of 10A." "It has large choice of number of contacts for high rated current use with space-saving design." "It also offers one-step lockable test button and “Power On” LED for readiness." "It helps to reduce the size of enclosures and increase machine reliability, you can mount nearly everywhere." "The product is IP40 and has a transparent cover allowing operator to visually inspect the status of contacts." "Workability for hard-wired logic automated systems to complement the functions of industrial programmable logic controllers (PLCs)." "Status display with LED, clearly signal both in the day and night." 0 0 It conforms to international standards and certifications like IEC, CE, UL, CSA, EAC, Lloyd's, RoHS and REACH. "RXM Relay should be used with a RXZE socket (screw clamp, screw connector, push-in terminal). To protect against vibrations, plastic/metal clamp can be added to the socket. Protection modules and marking legend are also available." "It is sold in lots of 10 and reference includes relay only." 0 "The RXM plug-in relays are a series of industrial plug-in relays designed for both simple and complex automation systems and available with 2 CO (12A), 3 CO (10A), 4 CO (6A) contacts, 4 CO (3A) low level contacts." 0
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Cad Overall Depth : 80.35 mm
    • Cad Overall Height : 82.8 mm
  • Conformance Attributes
    • Product Certifications : UL, Lloyd's, CE, CSA, EAC, IECEE CB Scheme
    • Standards : UL 508, IEC 61810-1, CSA C22.2 No 14
  • Complementary Attributes
    • Ie Rated Operational Current : 5 A 250 V AC) NC IEC, 10 A 28 V DC) NO IEC, 10 A 250 V AC) NO IEC, 5 A 28 V DC) NC IEC, 10 A 30 V DC) UL, 10 A 277 V AC) UL
    • Uc Control Circuit Voltage : 110 V DC, 110 V
    • Ui Rated Insulation Voltage : 250 V IEC, 300 V CSA, 300 V UL
    • Control Circuit Type : DC
    • Line Rated Current : 10 A
    • Maximum Switching Capacity : 2500 VA/280 W
    • Maximum Switching Voltage : 250 V IEC
    • Minimum Switching Capacity : 170 mW 10 mA, 17 V
    • Rated Operational Voltage Limits : 88...121 V DC
    • Uimp Rated Impulse Withstand Voltage : 4 kV 1.2/50 µs
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Dielectric Strength : 1300 V AC between contacts with micro disconnection, 2000 V AC between coil and contact, 2000 V AC between poles
    • Drop Out Voltage Threshold : >= 0.1 Uc, >= 0.1 Uc
    • Load Current : 10 A 250 V AC, 10 A 28 V DC
    • Operating Rate : <= 1200 cycles/hour under load, <= 1200 cycles/hour under load, <= 18000 cycles/hour no-load, <= 18000 cycles/hour no-load, <= 1200 cycles/hour under load, <= 1200 cycles/hour under load, <= 18000 cycles/hour no-load, <= 18000 cycles/hour no-load
    • Shock Resistance : 10 gnin operation, 30 gnnot operating
    • Vibration Resistance : 3 gn +/- 1 mm 10-150 Hz)5 cycles in operation, 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating
    • Ie Rated Operational Current : 5 A 250 V AC) NC IEC, 10 A 28 V DC) NO IEC, 10 A 250 V AC) NO IEC, 5 A 28 V DC) NC IEC, 10 A 30 V DC) UL, 10 A 277 V AC) UL
    • Carbon Footprint Of The Distribution Phase A4 : 0.0050318838, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.0051015887, 0 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0002384922
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.3 kg CO2 eq., 0.3085613559
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 20 kg CO2 eq., 20.2353795165
    • Medium Desc : miniature plug in relay, Harmony Electromechanical Relays, 10A, 3CO, with LED, lockable test but to n, 110V DC
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Legacy Weee Scope : Out
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2106019EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Coil Consumption : 0.9 W
    • Average Resistance : 13440 Ohm 20 °C +/- 10 %
    • Compatibility Code : RXM
    • Contacts Material : AgNi
    • Contacts Type And Composition : 3 C/O
    • Control Type : lockable test button
    • Electrical Durability : 100000 cycles resistive
    • Mechanical Durability : 10000000 cycles
    • Operating Position : any position
    • Operating Time : 20 ms
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : plug-in relay
    • Protection Category : RT I
    • Range Of Product : Harmony Electromechanical Relays
    • Relay Type : miniature relay
    • Reset Time : 20 ms
    • Returnability : No
    • Safety Reliability Data : B10d = 100000
    • Series Name : RXM series
    • Shape Of Pin : flat (faston type)
    • Software Version : EIME v5.9.1
    • Status Led : with
    • Sustainable Packaging : Yes
    • Test Levels : level A group mounting
    • Total Lifecycle Carbon Footprint : 21 kg CO2 eq.
    • Utilisation Coefficient : 20 %
    • Ithe Conventional Enclosed Thermal Current : 10 A
    • Control Circuit Voltage : 110 V
    • Control Circuit Type2 : DC
    • Pep Code : ENVPEP2106019EN
    • Database Version : 2016-11
    • Pep Verification Date : 2021-12-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : RXM.AB Miniature plug-in relay is to control a circuit by a low-power signal with complete electrical isolation between control and controlled circuits or where several circuits must be controlled by one signal .This range consists of RXM2AB, RXM3AB, RXM4AB/GB series. The range consists of miniature electromagnetic relays with 2, 3 or 4 C/O contacts with/without LED indicator and push button. The control voltage ranging from 24 Vac to 230 Vac and 12 Vdc.to 220Vdc with rated current 12A and product meets IEC 61810-1, UL 508 standards.
    • Functional Unit Unit : Unit
    • Energy Model Manufacturing A1 A3 2 : Energy model used: China
    • Energy Model Installation A5 2 : Electricity mix; AC; 120V; US
    • Energy Model Use B6 2 : Electricity mix; AC; 120V; US
    • Energy Model End Of Life C1 C4 2 : Electricity mix; AC; 120V; US
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -40-55 °C, -40-55 °C
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Carbon Footprint : 20.5543128371
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI2106019EN
    • Environmental Disclosure : ENVPEP2106019EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP40 conforming to IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2106019EN
    • Pep Verification Date : 2021-12-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : plug-in relay
    • Range Of Product : Harmony Electromechanical Relays
  • ETIM
    • ETIM 8 : EC001437
    • ETIM 9 : EC001437
  • Output Attributes
    • Continuous Output Current : 6.7 A
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Overview Attributes
    • Device Presentation : complete product