Fuse carrier, TeSys DF, 3P, 32A, 690VAC, fuse size 10x38mm, blown fuse indicator

FUSEHOLDER 600V 30AMP 3POLES 1

SQDDF103V DF103V 3389119407328
61.54 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Warranty Length: 18 mth
TeSys DF modular fuse carrier, 3 poles (3P), for protection of control circuits up to 32A/690V. To be used with 10x38mm fuse links up to 32A and short circuit current up to 120kA@400V. It provides blown fuse indication by LED. Compact (52.5mm width), it
QTY
  • Product Description
  • Features
  • Specifications
TeSys DF modular fuse carrier, 3 poles (3P), for protection of control circuits up to 32A/690V. To be used with 10x38mm fuse links up to 32A and short circuit current up to 120kA@400V. It provides blown fuse indication by LED. Compact (52.5mm width), it
  • Control Type
    • toggle padlockable
  • Connections Terminals
    • screw clamp terminals 1 1-16 mm²rigid
    • screw clamp terminals 2 1-6 mm²rigid
    • screw clamp terminals 2 1-6
  • IE Rated Operational Current
    • 32 A 400 V AC
  • ITH Conventional Free Air Thermal Current
    • 32 A 20 °C
  • Prop 65
    • WARNING: Cancer - www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0.00037687500000000004
    • 0 kg CO2 eq.
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0 kg CO2 eq.
    • 0.0136125
  • Standards
    • EN/IEC 60947-3
    • EN/IEC 60269-2
    • UL 4248-1
    • CSA C22.2 No 4248-1
    • EN 45545-2: R22 HL2
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 1 kg CO2 eq.
    • 1.423125
  • UI Rated Insulation Voltage
    • 690 V AC
  • Mounting Position
    • vertical +/- 23°)
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
  • Fire Resistance
    • 960 °C IEC 60695-2-1
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 3 kg CO2 eq.
    • 2.775000000000001
  • Persona Type Ids
    • EU
    • LC
    • OM
    • OM8
    • PB
  • Short Circuit Withstand
    • 120 kA 400 V IEC 60947-3
    • 120 kA 500 V IEC 60947-3
  • Carbon Footprint Of The Distribution Phase A4
    • 0.04696875
    • 0 kg CO2 eq.
  • Tightening Torque
    • 2.2 N.m PZ2
    • 2.2 N.m flat Ø 5.5 mm
  • Utilisation Category
    • AC-20B IEC 60947-3
    • DC-20B IEC 60947-3
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Fuse Type
    • 0-32 A, aM
    • 0-32 A, gG
  • Product Compatibility
    • DF2CA fuse cartridge
    • DF2CN fuse cartridge
  • Power Dissipation In W
    • 3 W maximum power dissipation by fuse
  • Ambient Air Temperature For Operation
    • -40-70 °C with derating above 20°C
  • UE Rated Operational Voltage
    • 690 V AC
    • 690 V DC
  • Product Certifications
    • IEC
    • UL Recognized
    • CSA
    • CCC
    • EAC
    • DNV-GL
  • Physical Attributes
    • Fuse Size : 10 x 38 mm
  • Complementary Attributes
    • UIMP Rated Impulse Withstand Voltage : 6 kV
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Device Type : LV equipment - LV fuse - disconnector
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Manufacturing Carbon Footprint : 1.423125
    • Distribution Carbon Footprint : 0.04696875
    • Installation Carbon Footprint : 0.00037687500000000004
    • Use Carbon Footprint : 2.775000000000001
    • End Of Life Carbon Footprint : 0.0136125
    • WEEE Applicability : Finished product
    • WEEE Scope : In
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Conformity Date : 1919
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • China ROHS Label : 1
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Compatibility Code : DF10
    • Device Short Name : DF10
    • Energy Efficiency Optimized : False
    • Overvoltage Category : III
    • Package Weight Lbs : 135 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : fuse carrier
    • Range : TeSys
    • Range Of Product : TeSys fuse carriers
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 4 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 4.259083125000001
    • Pep Code : ENVPEP2010021EN
    • Pep Verification Date : 2020-10-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 135
    • Functional Unit Description : Protecting electrical circuits from current surges and guaranteeing the electrical safety of the system for 20 years. Impacts are given for a product unit (“declared unit”).
    • Functional Unit Quantity : 1
    • Functional Unit Unit : Unit
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 18.9216
    • Energy Model Manufacturing A1 A3 : Energy model used: France
    • Energy Model Installation A5 : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Energy Model Use B6 : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.00009755626044375
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0000973125
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.000000001726875
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.00000000001513125
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000002412
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000008184375
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 42.45944062500001
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 10.209375
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.6046875
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.005315625
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 31.50000000000001
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.14006249999999998
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 4.276496625
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 4.275
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.0014460000000000005
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.000050625
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Recycling Kg Total Life Cycle : 0.008184375
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.000590625
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.007593750000000001
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 10.088564040000001
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.00855
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000037125
    • Net Use Of Fresh Water M3 Installation A5 : 0.00000003375
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 10.080000000000002
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.00001029375
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 11.246149068750004
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.765
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.001479375
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.00001344375
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 10.350000000000003
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.12965625
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.000000344966265
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000001636875
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.0000000000826875
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.000000000000765
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000001809
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000002953125
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0075066292500000015
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.000601875
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000010321875
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000000095625
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.006900000000000002
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000037125
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 68.78175000000002
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 19.715625
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.6103125
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.00534375
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 48.30000000000002
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.15046874999999998
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 135.00653360625006
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 22.766343749999997
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 1.222194375
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.010701731249999999
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 110.70000000000005
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.30729375
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 7.6024074281250025
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.5484375
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0007846875
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.000007115625
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 7.0500000000000025
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.003178125
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 1.9546875
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 1.9546875
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 66.81300000000002
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 17.746875
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.6103125
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.00534375
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 48.30000000000002
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.15046874999999998
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.06384375
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.06384375
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 7.537719928125002
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.48374999999999996
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0007846875
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.000007115625
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 7.0500000000000025
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.003178125
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0016959375
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0016959375
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 361.77987187499997
    • Air Pollution M3 Manufacturing A1 A3 : 235.12499999999997
    • Air Pollution M3 Distribution A4 : 5.79375
    • Air Pollution M3 Installation A5 : 0.015496875
    • Air Pollution M3 Operational Energy Use B6 : 119.40000000000002
    • Air Pollution M3 End Of Life C1 C4 : 1.445625
    • Water Pollution M3 Total Life Cycle : 528.3780937500001
    • Water Pollution M3 Manufacturing A1 A3 : 405
    • Water Pollution M3 Distribution A4 : 7.0875
    • Water Pollution M3 Installation A5 : 0.06215625
    • Water Pollution M3 Operational Energy Use B6 : 114.60000000000004
    • Water Pollution M3 End Of Life C1 C4 : 1.6284375
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 0.015291105000000004
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.0011265081562500002
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.0014224846875000002
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.0024834375
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.0011728125
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.00000169875
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 0.011580000000000003
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.00005315624999999999
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 4.259083125000001
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 1.423125
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.04696875
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.00037687500000000004
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 2.775000000000001
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.0136125
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.00042750000000000004
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.00005878125
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.00000012065625
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.0006360000000000002
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.00000410625
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.0005428125
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.00011953125000000001
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0000003909375
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.0006990000000000002
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.00006075
    • Warranty In Months : 18
  • General Attributes
    • Product Or Component Type : fuse carrier
    • Range Of Product : TeSys fuse carriers
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=604658&lang=en-us
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 4.259083125000001
    • Ambient Air Temperature For Storage : -40-70 °C
    • Environmental Disclosure : ENVPEP2010021EN
    • EU ROHS Directive : Compliant
    • IP Degree Of Protection : IP20
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2010021EN
    • Pep Verification Date : 2020-10-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : France