Fuse carrier, TeSys DF, 1P, 125A, 690VAC, fuse size 22x58mm, blown fuse indicator

FUSEHOLDER 600V 125AMP 1POLE 2

SQDDF221V DF221V 3389118233409
49.17 / EA
http://schema.org/OutOfStock
  • Country of Origin: Tunisia
  • Depth: 76.5 mm
  • Fuse Type: AM, GG
  • Warranty Length: 18 mth
TeSys DF modular fuse carrier, 1 pole (1P), for protection of control circuits up to 125A/690V. To be used with 22x58mm fuse links up to 125A and short circuit current up to 120kA@400V. It provides blown fuse indication by LED. Compact (35mm width), it can be used in modular panels, clipping on 35mm DIN rail, connection by screw terminals. Fuse links (22x58mm aM, gG type) and add-on auxiliaries (fuse carrier assembly kits, clip-in markers) are available (to be ordered separately). Sold in lots of 6 units. Multi standards certified (IEC, UL recognized, CSA, EAC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys DF modular fuse carrier, 1 pole (1P), for protection of control circuits up to 125A/690V. To be used with 22x58mm fuse links up to 125A and short circuit current up to 120kA@400V. It provides blown fuse indication by LED. Compact (35mm width), it can be used in modular panels, clipping on 35mm DIN rail, connection by screw terminals. Fuse links (22x58mm aM, gG type) and add-on auxiliaries (fuse carrier assembly kits, clip-in markers) are available (to be ordered separately). Sold in lots of 6 units. Multi standards certified (IEC, UL recognized, CSA, EAC).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Fuse Size : 22 x 58 mm
  • Complementary Attributes
    • Short Circuit Withstand : 120 kA 400 V IEC 60947-3, 120 kA 500 V IEC 60947-3, 80 kA 690 V IEC 60947-3
    • Ue Rated Operational Voltage : 690 V AC, 690 V DC
    • Ie Rated Operational Current : 125 A
    • Ipk Rated Peak Withstand Current : 19 kA with tubular links IEC 60269-1
    • Ui Rated Insulation Voltage : 690 V AC
    • Uimp Rated Impulse Withstand Voltage : 8 kV
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Control Type : toggle
    • Fuse Type : , gG, , aM, gG, , aM
    • Mounting Position : vertical +/- 23°)
    • Mounting Support : 35 mm symmetrical DIN rail
    • Poles Description : 1P, 1P
    • Product Or Component Type : fuse carrier
    • Protective Treatment : TH
    • Range : TeSys
    • Short Circuit Withstand : 120 kA 400 V IEC 60947-3, 120 kA 500 V IEC 60947-3, 80 kA 690 V IEC 60947-3
    • Tightening Torque : 4 N.m
    • Connections Terminals : screw clamp terminals 2 2.5-25 mm²flexible with or withoutscrew clamp terminals 1 2.5-35 mm²rigid, screw clamp terminals 2 2.5-25 mm²rigid, screw clamp terminals 1 2.5-35 mm²flexible with or without
    • Carbon Footprint Of The Distribution Phase A4 : 0.06401666666666667, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0 kg CO2 eq., 0.01855333333333333
    • Carbon Footprint Of The Installation Phase A5 : 0.0005136666666666667, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 1.9396666666666669
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 0.9 kg CO2 eq., 0.925
    • Certificate Agency : IEC, UL Recognized, CSA, EAC
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV fuse - disconnector
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Use Carbon Footprint : 0.925
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1919
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : DF22
    • Device Short Name : DF22
    • Energy Efficiency Optimized : False
    • Fire Resistance : 960 °C IEC 60695-2-1
    • Local Signalling : blown fuse indication
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys DF
    • Quantity Per Set : set of 6
    • Range Of Product : TeSys fuse carriers
    • Returnability : No
    • Software Version : EIME v5.8.1
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 3 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ie Rated Operational Current : 125 A
    • Ipk Rated Peak Withstand Current : 19 kA with tubular links IEC 60269-1
    • Warranty In Months : 18
    • Fuse Type 9 Fuse Type : aM
    • Pep Code : ENVPEP2010021EN
    • Database Version : 2016-11
    • Pep Verification Date : 2020-10-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Protecting electrical circuits from current surges and guaranteeing the electrical safety of the system for 20 years. Impacts are given for a product unit (“declared unit”).
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Energy model used: France
    • Energy Model - Installation [A5] : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Energy Model - Use [B6] : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Energy Model - End Of Life [C1-c4] : Electricity grid mix; AC; consumption mix, at consumer; < 1kV; EU-27
    • Offer Owner Code : 190788
    • Pn : 1
    • Height Nominal : 127.5 mm
    • Width Nominal : 35 mm
    • Air Pollution (M3) Operational Energy Use [B6] : 39.8
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 10.5
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 0.1909
    • Global Warming (Kg.Equivalent.Co2) Operational Energy Use [B6] : 0.925
    • Net Use Of Fresh Water (M3) Operational Energy Use [B6] : 3.36
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 3.45
    • Radioactive Waste Disposed Of (Kg) Operational Energy Use [B6] : 0.0023
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 16.1
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 0.7475
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 2.35
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 16.1
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 2.35
    • Water Pollution (M3) Manufacturing [A1-a3] : 552
    • Water Pollution (M3) Distribution [A4] : 9.66
    • Water Pollution (M3) Operational Energy Use [B6] : 38.2
    • Water Pollution (M3) End Of Life [C1-c4] : 2.2195
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -20-60 °C with derating above 20°C, -20-60 °C with derating above 20°C-20-60 °C with derating above 20°C, -20-60 °C with derating above 20°C
    • Product Compatibility : DF2FA fuse cartridge, DF2FN fuse cartridge
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 2.9477503333333335
    • Ambient Air Temperature For Storage : -40-80 °C-40-80 °C
    • Environmental Disclosure : ENVPEP2010021EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2010021EN
    • Pep Verification Date : 2020-10-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : fuse carrier
    • Range Of Product : TeSys fuse carriers
  • ETIM
    • ETIM 8 : EC002705
    • ETIM 9 : EC002705
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Tunisia
    • Depth : 76.5 mm