Schneider Electric at Mayer

Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 150A, 100-250VAC/DC coil

CONTACTOR, HIGH POWER, TESYS G

SQDLC1G150KUEN LC1G150KUEN 3606481921932
666.00 / EA
http://schema.org/OutOfStock
  • Depth: 193 mm
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 150A 90kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified (CE,CB,CCC,cULus,EAC,KC,RCM,Marine). Unique QR code provides quick access to complete product data.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color : dark grey
  • Conformance Attributes
    • Product Certifications : CB Scheme, CCC, cULus, EAC, CE, UKCA, EU-RO-MR by DNV-GL
    • Standards : EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-1, UL 60335-2-40:Annex JJ
  • Complementary Attributes
    • Control Circuit Voltage Limits : operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C), drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
    • Maximum Horse Power Rating : 40 hp at 200/208 V 60 Hz, 50 hp at 230/240 V 60 Hz, 100 hp at 460/480 V 60 Hz, 125 hp at 575/600 V 60 Hz
    • Maximum Operating Rate : 600 cyc/h AC-3, 600 cyc/h AC-3e, 300 cyc/h AC-1, 150 cyc/h AC-4
    • Icw Rated Short Time Withstand Current : 1.2 kA - 10 s, 0.7 kA - 30 s, 0.6 kA - 1 min, 0.45 kA - 3 min, 0.35 kA - 10 min
    • Ie Rated Operational Current : 275 A (at <40 °C) at <= 1000 V AC-1, 150 A (at <60 °C) at <= 440 V AC-3
    • Uc Control Circuit Voltage : 100...250 V, 100...250 V AC 50/60 Hz, 100...250 V DC
    • Ue Rated Operational Voltage : <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 460 V DC, <= 460 V DC, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 460 V DC, <= 460 V DC
    • Irms Rated Making Capacity : 1890 A at 440 V
    • Maximum Motor Phase Current : 150 A
    • Rated Breaking Capacity : 1280 A at 440 V
    • Ui Rated Insulation Voltage : 1000 V
    • Uimp Rated Impulse Withstand Voltage : 8 kV
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8, PB
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 160 A aM at <= 440 V for motor, 160 A aM at <= 690 V for motor, 315 A gG at <= 690 V, 300 A UL Type J at <= 600 V
    • Contactor Application : power switching, motor control
    • Electrical Durability : 300 cycles AC-1 400 V, 500 cycles AC-3 400 V, 500 cycles AC-3e 400 V, 150 cycles AC-4 400 V
    • Mechanical Robustness : vibrations 5-300 Hz 2 gn contactor open, vibrations 5-300 Hz 4 gn contactor closed, shocks 10 gn 11 ms contactor open, shocks 15 gn 11 ms contactor closed
    • Motor Power Kw : 75 kW at 400 V AC 50/60 Hz (AC-3), 75 kW at 415 V AC 50/60 Hz (AC-3), 90 kW at 440 V AC 50/60 Hz (AC-3), 90 kW at 500 V AC 50/60 Hz (AC-3), 90 kW at 690 V AC 50/60 Hz (AC-3), 75 kW at 1000 V AC 50/60 Hz (AC-3), 75 kW at 400 V AC 50/60 Hz (AC-4), 75 kW at 415 V AC 50/60 Hz (AC-4), 90 kW at 500 V AC 50/60 Hz (AC-4), 90 kW at 690 V AC 50/60 Hz (AC-4), 75 kW at 1000 V AC 50/60 Hz (AC-4), 37 kW at 230 V AC 50/60 Hz (AC-3e), 75 kW at 400 V AC 50/60 Hz (AC-3e), 75 kW at 415 V AC 50/60 Hz (AC-3e), 90 kW at 440 V AC 50/60 Hz (AC-3e), 90 kW at 500 V AC 50/60 Hz (AC-3e), 90 kW at 690 V AC 50/60 Hz (AC-3e), 75 kW at 1000 V AC 50/60 Hz (AC-3e), 37 kW at 230 V AC 50/60 Hz (AC-3), 37 kW at 230 V AC 50/60 Hz (AC-4), 80 kW at 440 V AC 50/60 Hz (AC-4)
    • Operating Time : 40...70 ms closing, 15...50 ms opening
    • Power Dissipation Per Pole : 10 W AC-1 - Ith 275 A, 5 W AC-3 - Ith 150 A
    • Safety Reliability Level : B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1, B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Utilisation Category : AC-1, AC-3, AC-3e, AC-4, AC-5a, AC-5b, AC-6a, AC-6b, AC-8a, AC-8b, DC-1, DC-3, DC-5
    • Connections Terminals : control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end, power circuit: bar 2 - busbar cross section: 25 x 6 mm, power circuit: lugs-ring terminals 1 185-185 mm², power circuit: bolted connection, control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end, control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end, control circuit: push-in 2 0.5-1.0 mm² with cable end, control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end
    • Icw Rated Short Time Withstand Current : 1.2 kA - 10 s, 0.7 kA - 30 s, 0.6 kA - 1 min, 0.45 kA - 3 min, 0.35 kA - 10 min
    • Ie Rated Operational Current : 275 A (at <40 °C) at <= 1000 V AC-1, 150 A (at <60 °C) at <= 440 V AC-3
    • Carbon Footprint Of The Distribution Phase A4 : 7.10052399768008, 7 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 6.237541510598823, 6 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.058803294325296185
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 39 kg CO2 eq., 39.176010870068204
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 633 kg CO2 eq., 633.2281586353371
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Weee Scope : In
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2105013
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2121
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 0.00018 Ohm
    • Coil Technology : built-in bidirectional peak limiting
    • Compatibility Code : LC1G
    • Connection Pitch : 35 mm
    • Device Short Name : LC1G
    • Halogen Free Status : Halogen free plastic parts product
    • Hold In Power Consumption In Va : 12.4-12.4 VA
    • Hold In Power Consumption In W : 7.8-7.8 W
    • Inrush Power In Va : 540-540 VA
    • Inrush Power In W : 380 W
    • Mechanical Durability : 8 Mcycles
    • Mounting Support : plate
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : TH
    • Range : TeSys
    • Range Of Product : TeSys Giga
    • Returnability : Yes
    • Software Version : v6.2.4
    • Sustainable Packaging : Yes
    • Tightening Torque : 18 N.m
    • Total Lifecycle Carbon Footprint : 686 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 275 A (at 40 °C)
    • Rated Thermal Current Ith : 275 A
    • Warranty In Months : 18
    • Control Circuit Voltage : 100...250 V
    • Inf Motor Phase Current : 150 A
    • Rated Thermal Current Hv : 275 A
    • Pep Code : ENVPEP2105013EN
    • Database Version : 2024-01
    • Pep Verification Date : 2026-03-19
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 4614.7
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 766.5
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; China, CN
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; China, CN
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Recyclability Potential In 2 : 55
    • Offer Owner Code : 190788
    • Height Nominal : 193 mm
    • Width Nominal : 108 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ip Degree Of Protection : IP2X front face with shrouds IEC 60529, IP2X front face with shrouds VDE 0106
    • Permissible Ambient Air Temperature Around The Device : -40-70 °C at Uc, -40-70 °C at Uc, -40-70 °C at Uc, -40-70 °C at Uc
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 685.8010383080094
    • Ambient Air Temperature For Operation : -25-60 °C
    • Ambient Air Temperature For Storage : -60-80 °C
    • Circularity Profile : ENVEOLI2105013
    • Environmental Disclosure : ENVPEP2105013EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2105013EN
    • Pep Verification Date : 2026-03-19
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Giga
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Specifications
    • Country of Origin : Brazil, China, Costa Rica, Czechia, France, United States
    • Depth : 193 mm