Schneider Electric at Mayer

Circuit breaker, PowerPacT H, 60A, 3 pole, 600VAC, 50kA, lugs, Micrologic 3.2S, 80%

CIRCUIT BREAKER, POWERPACT H,

SQDHLP36060U33X HLP36060U33X 3606487055037
4965.22 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 86 mm
  • Height: 163 mm
  • Length: 16 mm
  • Net Weight: 2.2 kg
  • Weight: 2.2 kg
  • Width: 104 mm
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2S trip unit and an LSI function with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has terminal nuts on the line side and lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
QTY
  • Product Description
  • Features
  • Specifications
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2S trip unit and an LSI function with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has terminal nuts on the line side and lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Ambient Air Temperature For Operation : -25-70 °C
    • Standards : UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
    • Product Certifications : UL || CSA || NOM
    • Ip Degree Of Protection : front cover IP40 IEC 60529
    • Pollution Degree : 3 IEC 60947-1
    • Ambient Air Temperature For Storage : -50-85 °C
    • Quality Labels : CE
    • Operating Altitude : < 6561.68 ft (2000 m) without derating || 5000 m with derating
  • Environmental data
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2206028EN
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI2206028EN
    • Take-Back : No
    • Pvc Free : Yes
    • Global Warming ; Total Life Cycle​ : 243 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 243.3333760794
  • Complementary
    • Mounting Mode : unit mount lug)
    • Network Frequency : 50/60 Hz
    • Terminal Identifier : AL150HD
    • [Ics] Rated Service Breaking Capacity : 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
    • Trip Unit Technology : electronic, standard, MicroLogic 3.2 S, LSI
    • Trip Unit Name : MicroLogic 3.2 S
    • Height : 163 mm
    • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz IEC 60947-3
    • Tightening Torque : 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
    • Mounting Support : lug
    • Breaking Capacity Code : L
    • Local Signalling : ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
    • Protected Poles Description : 3t
    • Number Of Slots : 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
    • Electrical Connection : terminal nut, line || lugs, load
    • Net Weight : 2.2 kg
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Control Type : toggle
    • Circuit Breaker Application : HACR rated
    • Wire Stripping Length : 16 mm
    • Line Rated Current : 60-60 A
    • Utilisation Category : category A
    • Long Time Pick-Up Adjustment Range : 0.25...1 x In
    • Continuous Current Rating : 80 %
    • Breaking Capacity : 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • Suitability For Isolation : yes IEC 60947-2
    • Communication Interface : Modbus || Ethernet
    • Poles Description : 3P
    • Quantity Per Set : 1
    • Awg Gauge : AWG 14...AWG 3/0 aluminium/copper terminal
    • Color : Black
    • Width : 104 mm
    • Depth : 86 mm
  • Specifications
    • Country of Origin : United States
    • Length : 16 mm
    • Width : 104 mm
    • Height : 163 mm
    • Weight : 2.2 kg
    • Product Or Component Type : circuit breaker
    • Product Name : PowerPact H
    • Range : PowerPact
    • Device Application : distribution