IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

SQDLC1D65M7 LC1D65M7 785901437284
485.66 / EACH
  • Certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 3 NO
  • Contact Configuration: 1 NO + 1 NC
  • Depth: 119 mm
  • Height: 127 mm
  • Net Weight: 1.4 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 75 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Complementary
    • [Ith] Conventional Free Air Thermal Current : 10 A 60 °C control circuit || 80 A 60 °C power circuit
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm
    • Control Circuit Voltage Limits : 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Maximum Height : 127 mm
    • Minimum Switching Current : 5 mA control circuit
    • Coil Technology : without built-in bidirectional peak limiting diode suppressor
    • Minimum Switching Voltage : 17 V control circuit
    • Rated Breaking Capacity : 1000 A 440 V power circuit IEC 60947
    • Maximum Depth : 119 mm
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Mounting Support : rail || plate
    • [Uc] Control Circuit Voltage : 220 V AC 50/60 Hz
    • Operating Time : 4...19 ms opening || 12...26 ms closing
    • Maximum Width : 75 mm
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Flame Retardance : V1 conforming to UL 94
    • Net Weight : 1.4 kg
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
    • [Ui] Rated Insulation Voltage : control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
    • Associated Fuse Rating : 10 A gG control circuit IEC 60947-5-1 || 125 A gG <= 690 V type 1 power circuit || 125 A gG <= 690 V type 2 power circuit
    • Inrush Power In Va : 140-140 VA 0.75 20 °C) || 160-160 VA 0.75 20 °C)
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Maximum Horse Power Rating : 5 hp 115 V at AC 60 Hz for 1 phase || 10 hp 230/240 V at AC 60 Hz for 1 phase || 20 hp 200/208 V at AC 60 Hz for 3 phase || 20 hp 230/240 V at AC 60 Hz for 3 phase || 40 hp 460/480 V at AC 60 Hz for 3 phase || 50 hp 575/600 V at AC 60 Hz for 3 phase
    • Power Dissipation Per Pole : 4.2 W AC-3 || 6.4 W AC-1
    • Insulation Resistance : > 10 MOhm control circuit
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
    • Mechanical Durability : 6000000 cycles
    • Irms Rated Making Capacity : 1000 A 440 V power circuit IEC 60947 || 140 A AC control circuit IEC 60947-5-1
    • Hold-In Power Consumption In Va : 13-13 VA 60 Hz 0.3 20 °C) || 15-15 VA 50 Hz 0.3 20 °C)
    • Terminals Description Iso N°1 : (13-14)NO || (21-22)NC || (A1-A2)CO
    • Overvoltage Category : III
    • Protective Cover : with
    • Connections - Terminals : control circuit screw clamp terminals 1 1-4 mm²rigid || control circuit screw clamp terminals 2 1-4 mm²rigid || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || power circuit screw terminals 1 2.5-25 mm²rigid || power circuit screw terminals 2 2.5-16 mm²rigid || power circuit screw terminals 1 2.5-25 mm²flexible without cable end || power circuit screw terminals 2 2.5-16 mm²flexible without cable end || power circuit screw terminals 1 2.5-25 mm²flexible with cable end || power circuit screw terminals 2 2.5-10 mm²flexible with cable end
  • Environment
    • Product Certifications : RINA || DNV || LROS (Lloyds register of shipping) || CCC || CSA || BV || UL || GL || GOST || UKCA
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Vibration Resistance : 2 gn 5-300 Hz contactor opened || 4 gn 5-300 Hz contactor closed
    • Ambient Air Temperature For Storage : -60-80 °C
    • Standards : IEC 60947-5-1 || CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || UL 508 || IEC 60947-4-1
    • Ip Degree Of Protection : IP2x IEC 60529 || IP2x VDE 0106
    • Shock Resistance : 10 gn contactor opened || 15 gn contactor closed
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Heat Dissipation : 4-5 W 50/60 Hz control circuit
  • Control Circuit Type : AC 50/60 Hz
  • Product Or Component Type : contactor
  • Device Short Name : LC1D
  • Motor Power Kw : 30 kW 440 V AC 50 Hz || 30 kW 380...400 V AC 50 Hz || 37 kW 500 V AC 50 Hz || 37 kW 660...690 V AC 50 Hz || 18.5 kW 220...230 V AC 50 Hz || 30 kW 415 V AC 50 Hz || 37 kW 1000 V AC 50 Hz
  • Range Of Product : TeSys D
  • [Ie] Rated Operational Current : 80 A 60 °C) <= 440 V AC AC-1 power circuit || 65 A 60 °C) <= 440 V AC AC-3 power circuit
  • Utilisation Category : AC-3 || AC-1 || AC-2 || AC-4
  • Range : TeSys
  • Pole Contact Composition : 3 NO
  • Contactor Application : resistive load || motor control
  • Poles Description : 3P
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Reach Free Of Svhc : Yes
    • Mercury Free : Yes
    • Circularity Profile : ENVEOLI1503009EN
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Sustainable Offer Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Rohs Exemption Information : Yes
    • Environmental Disclosure : ENVPEP1503009EN
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Eu Rohs Directive : Compliant
    • Pvc Free : Yes