Schneider Electric at Mayer

Busbar, Linergy HK, 160A, 4 conductors, L452mm, for mounting in enclosure W800mm

18"" BUSBAR"

SQDAK5JB144 AK5JB144 3389110576795
266.00 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
Linergy busbar for AC network. It applies to distribution, 12 Tap-offs and 4 conductors. The rated operational current is 160 A at 35 °C. Mounting by horizontal and vertical which using side stop AK5BT01 on mounting plates AK5PA. It provides protection for AM fuses, GF fuses and NS160H circuit breaker. IPxx B conforming to IEC 60529 and 850 °C fire resistance conforming to IEC 60695. It conforms to IEC 60439 standard. Multi standards certified (CSA, DNV, UL, LROS (Lloyds register of shipping). It conforms to RoHS.
QTY
  • Product Description
  • Features
  • Specifications
Linergy busbar for AC network. It applies to distribution, 12 Tap-offs and 4 conductors. The rated operational current is 160 A at 35 °C. Mounting by horizontal and vertical which using side stop AK5BT01 on mounting plates AK5PA. It provides protection for AM fuses, GF fuses and NS160H circuit breaker. IPxx B conforming to IEC 60529 and 850 °C fire resistance conforming to IEC 60695. It conforms to IEC 60439 standard. Multi standards certified (CSA, DNV, UL, LROS (Lloyds register of shipping). It conforms to RoHS.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Bar Length : 452 mm
    • Bar Width : 45 mm
  • Complementary Attributes
    • IE Rated Operational Current : 160 A 35 °C, 160 A 35 °C
    • UE Rated Operational Voltage : 400 V off-load plugging-in and unplugging, with supply switched on)IEC 60439-1, 400 V off-load plugging-in and unplugging, with supply switched on)IEC 60439-1, 400 V off-load plugging-in and unplugging, with supply switched on)IEC 60439-1, 480 V off-load plugging-in and unplugging, with supply switched on)CSA, 480 V off-load plugging-in and unplugging, with supply switched on)CSA, 480 V off-load plugging-in and unplugging, with supply switched on)CSA, 480 V off-load plugging-in and unplugging, with supply switched on)UL, 480 V off-load plugging-in and unplugging, with supply switched on)UL, 480 V off-load plugging-in and unplugging, with supply switched on)UL, 600 V plugging-in and unplugging, with supply switched off)CSA, 600 V plugging-in and unplugging, with supply switched off)CSA, 600 V plugging-in and unplugging, with supply switched off)CSA, 600 V plugging-in and unplugging, with supply switched off)UL, 600 V plugging-in and unplugging, with supply switched off)UL, 600 V plugging-in and unplugging, with supply switched off)UL, 690 V plugging-in and unplugging, with supply switched off)IEC 60439-1, 690 V plugging-in and unplugging, with supply switched off)IEC 60439-1, 690 V plugging-in and unplugging, with supply switched off)IEC 60439-1
    • UI Rated Insulation Voltage : 600 V CSA, 600 V CSA, 600 V UL, 600 V UL, 690 V IEC 60439-1, 690 V IEC 60439-1
  • Important Information Attributes
    • Persona Type Ids : LC, OM8, PB, SI
    • Persona Type Names : Contractor, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Fire Resistance : 850 °C IEC 60695, 850 °C IEC 60695
    • Flame Retardance : V0 conforming to UL 94, V0 conforming to UL 94
    • Mounting Position : vertical using side stop AK5BT01 on mounting plates AK5PA, vertical using side stop AK5BT01 on mounting plates AK5PA, horizontal
    • Protection Type : aM fuses In = 160 A, Isc = 100 kA, Ie = 160 A, aM fuses In = 160 A, Isc = 100 kA, Ie = 160 A, aM fuses In = 160 A, Isc = 100 kA, Ie = 160 A, aM fuses In = 160 A, Isc = 100 kA, Ie = 160 A, gF fuses In = 160 A, Isc = 100 kA, Ie = 160 A, gF fuses In = 160 A, Isc = 100 kA, Ie = 160 A, gF fuses In = 160 A, Isc = 100 kA, Ie = 160 A, gF fuses In = 160 A, Isc = 100 kA, Ie = 160 A, NS160H circuit breaker In = 160 A, Isc = 36 kA, Ie = 160 A, NS160H circuit breaker In = 160 A, Isc = 36 kA, Ie = 160 A, NS160H circuit breaker In = 160 A, Isc = 36 kA, Ie = 160 A, NS160H circuit breaker In = 160 A, Isc = 36 kA, Ie = 160 A, NS160H circuit breaker In = 160 A, Isc = 70 kA, Ie = 160 A, NS160H circuit breaker In = 160 A, Isc = 70 kA, Ie = 160 A, NS160H circuit breaker In = 160 A, Isc = 70 kA, Ie = 160 A, NS160H circuit breaker In = 160 A, Isc = 70 kA, Ie = 160 A
    • IE Rated Operational Current : 160 A 35 °C, 160 A 35 °C
    • Connections Terminals : connector 2.5-70 mm² flexible with cable end, connector 2.5-70 mm² flexible with cable end, connector 2.5-70 mm² flexible with cable end, connector 2.5-70 mm² flexible with cable end, connector 2.5-70 mm² rigid, connector 2.5-70 mm² rigid, connector 2.5-70 mm² rigid
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-13
    • Device Type : Busway & cable - busbar, connection, grounding
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Halogen Free Status : Halogen free plastic parts product
    • Network Type : AC
    • Package Weight Lbs : 1.161 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : busbar
    • Range : Linergy
    • Range Of Product : AK5
    • Returnability : No
    • Sustainable Packaging : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • IP Degree Of Protection : IPxx B conforming to IEC 60529, IPxx B conforming to IEC 60529
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Silicon Free : Yes
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
  • General Attributes
    • Product Or Component Type : busbar
    • Range Of Product : AK5
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months