IEC contactor, TeSys Deca, auxiliary contact block, 2 NO, front mounting, spring terminals

CONTACTOR AUXILIARY CONTACT BL

SQDLADN203 LADN203 3389110821154
30.55 / EA
http://schema.org/OutOfStock
  • Certifications: CB, CCC, CSA, EAC, UKCA, UL
  • Contact Configuration: 2 NO
  • Depth: 42 mm
  • Height: 48 mm
  • Standard: CSA C22.2 No 60947-5-1, EN 50012, EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 26 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This auxiliary contact block has 2 normally open contacts. This auxiliary contact block mounts on the top of TeSys D contactors and control relays. Spring terminals are used for connections. The auxiliary contact block is 1.89 inches tall, 1.02 inches wide and 1.65 inches deep. The block is UL Listed.
QTY
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This auxiliary contact block has 2 normally open contacts. This auxiliary contact block mounts on the top of TeSys D contactors and control relays. Spring terminals are used for connections. The auxiliary contact block is 1.89 inches tall, 1.02 inches wide and 1.65 inches deep. The block is UL Listed.
  • Environment
    • Ambient Air Temperature For Operation : -5-60 °C
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Ambient Air Temperature For Storage : -60-80 °C
    • Environmental Characteristic : normal environment
    • Protective Treatment : TH IEC 60068
    • Operating Altitude : 9842.52 ft (3000 m)
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110807EN_V3
    • Sustainable Offer Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Circularity Profile : N/A
    • Eu Rohs Directive : Compliant
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact
    • Permissible Short-Time Rating : 100 A 60 °C 1 s || 120 A 60 °C 500 ms || 140 A 60 °C 100 ms
    • Minimum Switching Current : 5 mA
    • Height : 48 mm
    • Protection Type : gG fuse 10 A
    • Insulation Resistance : > 10 MOhm
    • Irms Rated Making Capacity : 140 A AC conforming to IEC 60947-5-1 || 250 A DC conforming to IEC 60947-5-1
    • Connections - Terminals : spring terminals 2 2.5-2.5 mm²flexible without cable end || spring terminals 2 2.5-2.5 mm²rigid
    • Minimum Switching Voltage : 17 V
    • Mechanical Durability : 30 Mcycles
    • Color : dark grey
    • Width : 26 mm
    • Depth : 42 mm
  • Specifications
    • Product Certifications : CB || UL || CSA || CCC || EAC || UKCA
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C)
    • Standards : EN/IEC 60947-5-1 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.5 || EN 50012
    • [Ue] Rated Operational Voltage : 690 V AC 25...400 Hz
    • Range Compatibility : TeSys D CAD || TeSys D LC1D || TeSys Deca CAD || TeSys Deca LC1D
    • Product Or Component Type : auxiliary contact block
    • Product Name : TeSys Deca
    • Range : TeSys || TeSys Deca
    • Mounting Location : front
    • Pole Contact Composition : 2 NO
    • [Ui] Rated Insulation Voltage : 690 V IEC 60947-5-1 || 600 V UL || 600 V CSA
    • [Ie] Rated Operational Current : 6 A at 120 V AC-15 || 1.04 A at 690 V AC-15 || 0.55 A at 125 V DC-13 || 0.1 A at 600 V DC-13
    • Auxiliary Contacts Operation : instantaneous
    • Device Short Name : LADN