Schneider Electric at Mayer

Auxiliary contact block, TeSys Deca, 2NC, side mounting, screw clamp terminals

CONTACTOR AUXILIARY CONTACT BL

SQDLAD8N02 LAD8N02 3389110384499
32.03 / EA
http://schema.org/OutOfStock
  • Depth: 71.3 mm
  • Warranty Length: 18 mth
  • Weight: 55 g
TeSys Deca instantaneous auxiliary contact block, for LC.D contactors and CAD control relays with AC coils only. It provides 2NC contacts (NC mirror certified) rated up to 10A 690V AC, connection by screw clamp terminals. Clip-on side mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC).
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca instantaneous auxiliary contact block, for LC.D contactors and CAD control relays with AC coils only. It provides 2NC contacts (NC mirror certified) rated up to 10A 690V AC, connection by screw clamp terminals. Clip-on side mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC).
  • Features
    • Meet the need for more control contact for TeSys Deca contactor and control relay
    • Easy choice for simple applications
    • Improved fire resistancy with IEC 60335-1 (Clause 30.2) certificate by authorized agency
    • Anti-flammable refrigerants with IEC/EN/UL 60335-2-40 (Annex JJ) certificate by authorized agency
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer and/or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
  • Complementary Attributes
    • Ie Rated Operational Current : 6 A at 120 V AC-151.04 A at 690 V AC-15, 0.55 A at 125 V DC-130.1 A at 600 V DC-13
    • Ui Rated Insulation Voltage : 690 V IEC 60947-5-1600 V UL, 600 V CSA
    • Irms Rated Making Capacity : 140 A AC conforming to IEC 60947-5-1250 A DC conforming to IEC 60947-5-1
    • Minimum Switching Current : 5 mA
    • Minimum Switching Voltage : 17 V
    • Ue Rated Operational Voltage : 690 V AC 25...400 Hz
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Tightening Torque : 1.7 N.m flat Ø 6 mm, 1.7 N.m Philips No 2, 1.7 N.m pozidriv No 2
    • Connections Terminals : screw clamp terminals 2 1-4 mm²flexible without cable endscrew clamp terminals 2 1-4 mm²rigid without cable endscrew clamp terminals 1 1-4 mm²flexible with cable end, screw clamp terminals 1 1-4 mm²flexible without cable end, screw clamp terminals 2 1-2.5 mm²flexible with cable end, screw clamp terminals 1 1-4 mm²rigid without cable end
    • Certificate Agency : CB Scheme, UL, CSA, CCC, EAC, UKCA
    • Non Overlap Time : 1.5 ms on de-energisation no overlap between NC and NO contact, 1.5 ms on energisation no overlap between NC and NO contact
    • Carbon Footprint Of The Distribution Phase A4 : 0.06786586045038151, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.2 kg CO2 eq., 0.15462428493948835
    • Carbon Footprint Of The Installation Phase A5 : 0.008480726561347006, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.4 kg CO2 eq., 0.41771858290220826
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 3 kg CO2 eq., 3.1606
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-07-07
    • Return Indicator : Y
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Use Carbon Footprint : 3.1606
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1929
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : LA1
    • Environmental Characteristic : normal environment
    • Insulation Resistance : > 10 MOhm> 10 MOhm
    • Mechanical Durability : 30 Mcycles
    • Mounting Location : side
    • Pole Contact Composition : 2 NC
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys Deca
    • Product Or Component Type : auxiliary contact block
    • Protection Type : gG fuse 10 A
    • Protective Treatment : TH IEC 60068
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Shielding Continuity Terminal : without
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 4 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pole Contact Comp : 2 NC
    • Database Version : 2022-01
    • Data Source : extrapolated product
    • Height Nominal : 72 mm
    • Width Nominal : 12.5 mm
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 8536509065
    • Ith Conventional Free Air Thermal Current : 10 A (at 60 °C)
    • Permissible Short Time Rating : 100 A 1 s120 A 500 ms140 A 100 ms
    • Warranty In Months : 18
    • Functional Unit Description : To add instantaneous auxiliary contact blocks in front face on TeSys k contactors as NO and NC contacts for 20 years.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 20
    • Recyclability Potential In % : 39
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -5-60 °C, -5-60 °C
    • Ambient Air Temperature For Storage : -60-80 °C, -60-80 °C
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 3.8092894548534253
    • Environmental Disclosure : ENVPEP1108007EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 conforming to IEC 60529
    • Operating Altitude : 9842.52 ft (3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Product Compatibility : LC1D80...D95
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1108007EN
    • Pep Verification Date : 2025-06-17
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : auxiliary contact block
    • Range Of Product : TeSys Deca
  • ETIM
    • ETIM 8 : EC000041
    • ETIM 9 : EC000041
    • ETIM 10 : EC000041
  • Contractual Warranty Attributes
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Indonesia, United States
    • Weight : 55 g
    • Depth : 71.3 mm