Active harmonic filter 200 amp 208-240 VAC N12 Enclosure

Active harmonic filter 200 amp 208-240 VAC N12 Enclosure

SQDPCSP200D2N12 3606489905569
397307.22 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 600 mm
This hardware is an active power correction solution, from AccuSine familly, to help stabilize electrical networks by providing harmonic mitigation and power factor correction, and load balancing. It is specifically designed for harsh electrical conditions, for heavy industrial applications including mission critical environments. This version is UL Type 12, close to ingress protection IP54, and can be connected on Low Voltage networks rated 208 Volt to 240 Volt. It is specified for a standard Root Mean Square output current rating of 200 Amps. The enclosure is floor standing, allow cable entry from top or bottom and is delivered in RAL7035 light grey. This active power filter achieves above standards performance THDi less or equal to 3%, is certified to CE, UL, IBC 2015 AC156, EAC, RCM. And is designed to IEC 62477-1, IEC 61000-6-2, IEC 61000-6-4, IEC 61439-1, UL508 and IEEE 519-2014. Up to 10 units of different ratings can be paralleled, to achieve a maximum compensation of 3000A per CT set. Frame exterior dimensions are 900 millimetres in width, 600 millimetres in depth, 2100 millimetres in height and product weight 402 kg.
QTY
  • Product Description
  • Features
  • Specifications
This hardware is an active power correction solution, from AccuSine familly, to help stabilize electrical networks by providing harmonic mitigation and power factor correction, and load balancing. It is specifically designed for harsh electrical conditions, for heavy industrial applications including mission critical environments. This version is UL Type 12, close to ingress protection IP54, and can be connected on Low Voltage networks rated 208 Volt to 240 Volt. It is specified for a standard Root Mean Square output current rating of 200 Amps. The enclosure is floor standing, allow cable entry from top or bottom and is delivered in RAL7035 light grey. This active power filter achieves above standards performance THDi less or equal to 3%, is certified to CE, UL, IBC 2015 AC156, EAC, RCM. And is designed to IEC 62477-1, IEC 61000-6-2, IEC 61000-6-4, IEC 61439-1, UL508 and IEEE 519-2014. Up to 10 units of different ratings can be paralleled, to achieve a maximum compensation of 3000A per CT set. Frame exterior dimensions are 900 millimetres in width, 600 millimetres in depth, 2100 millimetres in height and product weight 402 kg.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Color : Light gray RAL 7035)
  • Conformance Attributes
    • Product Certifications : CE, ABS, cULus, RCM
    • Standards : UL 508, EN 60439-1, CSA C22.2 No 60947-1-07, CSA C22.2 No 14, UL 60947-1, EN 61000-6-4
  • Complementary Attributes
    • Maximum Permissible Voltage : 1.1 x Un
    • Network Rated Voltage : 208-240 V AC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Environmental Characteristic : operating 3C2 IEC 60721-3-3, operating 3S2 IEC 60721-3-3, storage 3C3 IEC 60721-3-3, storage 3S3 IEC 60721-3-3
    • Operating Mode : power factor correction, harmonic cancellation, mains current balancing
    • Carbon Footprint Of The Distribution Phase A4 : 292.7475436274485, 293 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 552 kg CO2 eq., 551.8179708307557
    • Carbon Footprint Of The Installation Phase A5 : 101.70926422424425, 102 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 205 kg CO2 eq., 3204.7448585940665
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 71 474 kg CO2 eq., 71473.68415881522
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : Surge Protection and Power Conditioning - Filters & Harmonic Conditioners
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 10 year(s)
    • Service Catalog Item : Finished good
    • Legacy Weee Scope : In
    • Weee Product Category : 4
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1507014EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2523
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 3
    • Tier : 3
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Control Type : door-interlocked with rotary handle
    • Electromagnetic Compatibility : conducted EMC, class A EN 61000-6-4
    • Enclosure Mounting : floor-standing
    • Function Available : rear plenum with forced ventilation for high heat flow
    • Impregnation Material : conformal coated
    • Location Of Connection : top or bottom
    • Mounting Location : indoor
    • Neutral Protection Setting : not provided
    • Poles Description : 3P
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : AccuSine PCS+
    • Product Or Component Type : active harmonic filter
    • Protection Type : circuit breaker protection
    • Range : AccuSine
    • Range Of Product : AccuSine
    • Reactive Power Rating : 83.1 kvar 240 V AC 50/60 Hz
    • Returnability : No
    • Software Version : v6.3.3
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 75 625 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Wiring Mode : 3 or 4 wires
    • Warranty In Months : 18
    • Pep Code : ENVPEP1507014EN
    • Database Version : 2025-04
    • Pep Verification Date : 2026-02-13
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : PowerLogic AccuSine™ PCSP is flexible, high performance solution to stabilize electrical networks by providing harmonic mitigation and power factor correction, and load balancing, according to the appropriate use scenario, and for a reference lifetime of 10 years.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 398000
    • Reference Lifetime In Y2 : 10
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; India, IN
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Recyclability Potential In 2 : 72
    • Offer Owner Code : 190781
    • Height Nominal : 2100 mm
    • Width Nominal : 900 mm
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : 0-40 °C, 0-50 °C maximum with current derating of 2 % per °C
    • Operating Altitude : <= 3280.84 ft (1000 m) 1 % per 100 m, <= 3280.84 ft (1000 m) 1 % per 100 m, <= 3280.84 ft (1000 m) 1 % per 100 m, <= 3280.84 ft (1000 m) 1 % per 100 m
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 75624.70379609174
    • Ambient Air Temperature For Storage : -20-60 °C
    • Circularity Profile : ENVEOLI1507014EN
    • Environmental Disclosure : ENVPEP1507014EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 0-95 %
    • Pep Code : ENVPEP1507014EN
    • Pep Verification Date : 2026-02-13
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : active harmonic filter
    • Range Of Product : AccuSine
  • Output Attributes
    • Nominal Output Current : 200 A
  • Input Attributes
    • Input Frequency : 50/60 Hz +/- 3 Hz auto sensing
  • Specifications
    • Country of Origin : United States
    • Depth : 600 mm