Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A

EXTERNAL NEUTRAL CURRENT TRANS

SQDS429521 S429521 785901770831
338.70 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, UL
  • Line Rated Current: 60-100 A
  • Warranty Length: 18 mth
Square D PowerPact H-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits Molded case circuit breakers are available with either thermal-magnetic or Micrologic electronic trip units. The external neutral current transformer is a required sensor for 3 pole circuit breaker in a system with a distributed neutral to measure the neutral current in oder to protect neutrak conducter and protect against ground faults. This current trasformer could be used with H-frame PowerPacT circuit breakers with current rating 60 to 100A The neutral current transformer is connected in the same way for unit-mount, plug-in or drawout devices, cross-sectional area is AWG 22-AWG 16.
QTY
  • Product Description
  • Specifications
Square D PowerPact H-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits Molded case circuit breakers are available with either thermal-magnetic or Micrologic electronic trip units. The external neutral current transformer is a required sensor for 3 pole circuit breaker in a system with a distributed neutral to measure the neutral current in oder to protect neutrak conducter and protect against ground faults. This current trasformer could be used with H-frame PowerPacT circuit breakers with current rating 60 to 100A The neutral current transformer is connected in the same way for unit-mount, plug-in or drawout devices, cross-sectional area is AWG 22-AWG 16.
  • Environment
    • Product Certifications : CSA || UL
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Line Rated Current : 60-100 A
    • Tightening Torque : 6-6 N.m (AWG 14...AWG 10)
  • Specifications
    • Range Of Product : PowerPact H || MicroLogic
    • Accessory / Separate Part Category : connection accessory
    • Product Or Component Type : current transformer