PASS & SEYMOUR

PlugTail® Hospital-Grade 20A Self-Test GFCI Receptacle, Red

PlugTail® Hospital-Grade 20A Self-Test GFCI Receptacle, Red

PSSPT2097HGRED PT2097-HGRED 785007048919
61.88 / EACH
  • Amperage: 20 A
  • Country of Origin: China
  • NEMA: 5-20R
  • Voltage: 125 V
The fastest-installing GFCI ever now conducts an automatic test every three seconds, ensuring it's always ready to protect. If the device fails the test, the indicator light flashes to signal that the GFCI should be replaced. It also has our proven SafeLock™ Protection feature: if critical components are damaged and protection is lost, power to the receptacle is disconnected. For detailed PlugTail® information, visit our PlugTail Headquarters.
  • Product Description
  • Features
  • Specifications
The fastest-installing GFCI ever now conducts an automatic test every three seconds, ensuring it's always ready to protect. If the device fails the test, the indicator light flashes to signal that the GFCI should be replaced. It also has our proven SafeLock™ Protection feature: if critical components are damaged and protection is lost, power to the receptacle is disconnected. For detailed PlugTail® information, visit our PlugTail Headquarters.
  • Meets 2015 UL requirements.
  • Faster, more reliable installation.
  • Auto-Ground clip assures a positive ground to metal box.
  • Supply Voltage: 125VAC, 60 Hz
  • Dual-direction test and reset buttons.
  • Trip Threshold: 5 +/- 1 mA
  • Tri-drive screws.
  • Mounting screws are shipped captive in the device and wall plate for easier installation.
  • Supply Voltage Range: 102-132 VAC
  • Zinc-plated steel mounting strap.
  • Built-in connector features large brass terminal blades to ensure consistent, reliable electrical connections to PlugTail® Connector.
  • Exceeds UL 943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles.
  • Supplied with matching TP wall plate.
  • GFCI works with existing 3-wire PlugTail Connectors creating a non-feed-thru application for facility owners.
  • Class A rated GFCI.
  • Button colors match the device face.
  • Conducts an automatic test every three seconds, ensuring it's always ready to protect. If the device fails the test, the indicator light flashes to signal that the GFCI should be replaced. It also has our proven SafeLock protection feature: if critical components are damaged and protection is lost, power to the receptacle is disconnected.
  • No exposed terminals create a finger-safe application before, during, and after installation.
  • Trip indicator light (red LED).
  • 10kA short circuit rating.
  • Trip Time: 0.025 sec., nominal per UL Standard
  • High-impact-resistant thermoplastic construction.
  • Thinner than competitors' GFCI Receptacles: leaves more room for wires in the box.
  • FSUL Listed (Federal Specification WC596).
  • Technical Information
    • Amps : 20A
    • Volts : 125
    • NEMA Configuration Number : 5-20R
  • General Info
    • Color : Red
  • Listing Agencies/Third Party Certifications
    • CSA Listed : No
    • Federal Spec : Yes
    • cULus : Yes
    • UL Standard : UL498
  • Buy American Act Compliance
    • Country Of Origin : CHINA