KLLU1200 - KLLU Series

KLLU1200 - KLLU Series

LFUKLLU1200 KLLU1200 079458271065
1031.81 / Each
  • Amperage: 1200 A
  • Voltage: 300 V, 600 V
KLLU series UL Listed, time-delay, Class L are quality fuses in every sense of the word. They were developed to provide a somewhat lower priced alternate to the POWR-PRO™ KLPC series fuses. KLLU series fuses meet or exceed all UL requirements for Class L fuses. For superior protection and performance, specification-grade POWR-PRO™ KLPC series fuses are the recommended fuses. Applications:
  • Product Description
  • Features
  • Specifications
KLLU series UL Listed, time-delay, Class L are quality fuses in every sense of the word. They were developed to provide a somewhat lower priced alternate to the POWR-PRO™ KLPC series fuses. KLLU series fuses meet or exceed all UL requirements for Class L fuses. For superior protection and performance, specification-grade POWR-PRO™ KLPC series fuses are the recommended fuses. Applications:
  • Safety
    • When used for motor branch circuit protection, KLLU fuses may be sized close to the motor full-load current, providing excellent protection to branch circuit conductors, motor control equipment and motors.
    • Current limiting — Reduces short circuit damage to systems and equipment.
    • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
    • 200,000 A.I.R. — Provides reliable interruption of all overcurrents up to 200,000 amperes.
    • Ten second minimum time delay at 500 percent of rating eliminates needless downtime caused by heavy starting currents of large motors and other inductive loads.
    • Reduced downtime
    • Selective coordination — KLLU fuses coordinate well with other Class L fuses and with all current-limiting Littelfuse fuses rated 600 amps or less. This means less time spent trying to locate short circuits or overloaded equipment, because only the fuse immediately on the line side of the affected circuit opens.
    • 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements.
  • Easy to Use
    • 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements.
    • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
  • Applications
    • Current limiting — Reduces short circuit damage to systems and equipment.
    • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
    • Service switches
    • Ten second minimum time delay at 500 percent of rating eliminates needless downtime caused by heavy starting currents of large motors and other inductive loads.
    • Selective coordination — KLLU fuses coordinate well with other Class L fuses and with all current-limiting Littelfuse fuses rated 600 amps or less. This means less time spent trying to locate short circuits or overloaded equipment, because only the fuse immediately on the line side of the affected circuit opens.
    • Motor control center mains
    • Switchboard mains and feeders
    • UL Listed series-rated protection for molded case circuit breaker panelboards and loadcenters. See panelboard manufacturer’s literature for recommended fuse rating.
    • Bolted pressure contact switches
    • When used for motor branch circuit protection, KLLU fuses may be sized close to the motor full-load current, providing excellent protection to branch circuit conductors, motor control equipment and motors.
    • Reduced downtime
    • 200,000 A.I.R. — Provides reliable interruption of all overcurrents up to 200,000 amperes.
    • Large motor branch circuits
    • 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements.
  • Longer Equipment Life
    • Ten second minimum time delay at 500 percent of rating eliminates needless downtime caused by heavy starting currents of large motors and other inductive loads.
    • Selective coordination — KLLU fuses coordinate well with other Class L fuses and with all current-limiting Littelfuse fuses rated 600 amps or less. This means less time spent trying to locate short circuits or overloaded equipment, because only the fuse immediately on the line side of the affected circuit opens.
    • 200,000 A.I.R. rating minimizes need for short circuit calculations…meets present and future system requirements.
    • KLLU fuse time-current characteristics closely match typical time-current curves of circuit breakers. Although fuse/circuit breaker systems can seldom be 100% coordinated , KLLU series fuses permit use of a wider range of breaker setting than fast-acting Class L fuses. Excellent protection for a single breaker or a group of breakers.
    • Current limiting — Reduces short circuit damage to systems and equipment.
    • Reduced downtime
  • Interrupting Rating : 200000A@600VAC
  • Opening : Slo-Blo/Time Lag (T)/Time Delay
  • Package Size : Bolt-In
  • VAC (V) : 600
  • VDC (V) : 300
  • Ampere Rating (A) : 1200