• Features
  • Specifications
  • Key Features
    • For electrical and electronic testing and troubleshooting in field service
    • Ideal where reliability and dependability are required
    • Min/Max/Average to record signal fluctuations
    • CAT III 600V
  • Product Overview
    • The Fluke 115 technicians digital multimeter offers simple, one-handed operation to meet the needs of a wide variety of field service technicians. It measures true-rms voltage and current with 6000 count resolution, plus resistance, continuity, frequency and capacitance.
    • The 115 DMM offers the users one-handed operation and a backlit display with large, easy-to-read digits.
  • Other Useful Features
    • Measures AC and DC voltage to 600V
    • Measures AC and DC current to 10A (20 A overload for 30-seconds max)
    • Measures resistance, continuity, frequency, and capacitance
    • Provides Min/Max/Average with elapsed time to record signal fluctuations
    • Include a holster with probe holders for easy storage and one-handed operation
    • Large white LED backlight for working in poorly lit areas
  • Includes
    • Holster
    • Installed 9V battery
    • 4 mm silicone test lead set
    • User manual
  • Additional Features
    • 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.
  • Accuracy Specifications
    • DC millivolts Range/resolution : 600.0 mV / 0.1 mV
    • DC millivolts Accuracy : ± ([% of reading] + [counts]): 0.5% + 2
    • DC volts Range/resolution : 6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V
    • DC volts Accuracy : ± ([% of reading] + [counts]): 0.5% + 2
    • AC millivolts1 True RMS Range/resolution : 600.0 mV / 0.1 mV
    • AC millivolts Accuracy : 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
    • AC volts1 True RMS Range/resolution : 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V
    • AC volts Accuracy : 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
    • Continuity Range/resolution : 600 Ω / 1 Ω
    • Continuity Accuracy : Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer.
    • Ohms Range/resolution : 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ || 40.00 MΩ / 0.01 MΩ
    • Ohms Accuracy : 0.9% + 1 || 5% + 2
    • Diode test Range/resolution : 2.00 V / 0.001 V
    • Diode test Accuracy : 0.9% + 2
    • Capacitance Range/resolution : 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF || > 1000 μF
    • Capacitance Accuracy : 1.9% + 2 || 5% + 20%
    • Lo-Z capacitance Range : 1 nF to 500 μF
    • Lo-Z capacitance Accuracy : 10% + 2 typical
    • AC amps True RMS(45 Hz to 500Hz) Range/resolution : 6.000 A / 0.001 A10.00 A / 0.01 A
    • AC amps True RMS Accuracy : 1.5% + 320 A overload for 30-seconds max
    • DC amps Range/resolution : 6.000 A / 0.001 A10.00 A / 0.01 A
    • DC amps Accuracy : 1.0% + 320 A overload for 30-seconds max
    • Hz (V or A input)2 Range/resolution : 99.99 Hz / 0.01 Hz999.9 Hz / 0.01 Hz9.999 kHz / 0.001 kHz50.00 kHz / 0.01 kHz
    • Hz (V or A input) Accuracy : 0.1% + 2
  • General Specifications
    • Maximum voltage between any terminal and earth ground : 600 V
    • Surge protection : 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
    • Display : Digital: 6,000 counts, updates 4 per second
    • Bar graph : 33 segments, updates 32 per second
    • Operating temperature : -10℃ to + 50℃
    • Storage temperature : -40℃ to + 60℃
    • Battery type : 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    • Battery life : 400 hours typical, without backlight
    • Size : 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    • Weight : 550 g
    • Warranty : 3 years