Fluke 113 Digital Multimeter

FLUKE MILTI METER W/ V -CHECK

FLKFLUKE113 FLUKE-113 95969434522
195.94 / BOX
http://schema.org/OutOfStock
  • Battery Type: 9 Volt Alkaline, IEC 6F22, IEC 6F22: 9 Volt Alkaline
  • Operating Temperature: -10 To 50 °C, 14 To 122 °F
  • Storage Temperature: -22 To 140 °F, -40 To 60 °C
1-rms Digital Multimeter designed for basic electrical tests. The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems. The Fluke 113 has significant improvements over other digital multimeters available on the market, including Fluke model 7-600. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Min/Max function lets you record signal fluctuations. The Fluke 113 can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.
QTY
  • Features
  • Specifications
  • Key Features
    • VCHEK™ LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.
    • Large backlit display
    • CAT IV 600 V safety rated
  • Product Overview
    • The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic testing. It is easy to use and is packed with the features needed to repair most electrical problems. The 113 features a large, backlit display for easy visibility in low-lit work environments. Plus, the integrated holster includes probe holders on the back, so your test leads can always be kept organized and where you need them.
    • Make measurements quickly with the 113
    • Whether you’re a utility worker, linesman, electrician, technician, anyone else working with basic electrical testing, the Fluke 113 includes the measurement features you need to tackle your job. The Fluke VCHEK™ LoZ low impedance measurement function lets users perform tests for voltage or continuity from the same dial position.
    • Please note that low impedance LoZ measurements will cause a low load on a circuit protected by a RCD, which will trip powered GFCI and RCD circuits when measuring Phase to Earth.
    • The meter also displays AC or DC voltage, depending on what was detected, while also rejecting ghost voltages from adjacent wires. If no voltage is detected, a continuity test is performed. The Min/Max function lets you record signal fluctuations.
    • The Fluke 113 digital multimeter can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.
  • Specifications
    • VCHEK1 2 3 Range : 6.000 V / 60.00 V / 600.0 V
    • VCHEK1 2 3 Resolution : 0.001 V / 0.01 V/ 0.1 V
    • VCHEK1 2 3 Accuracy : DC, 45 to 500 Hz: 2.0% + 3500 Hz to 1 kHz: 4.0% + 3
    • Diode test4 Range : 2.000 V
    • Diode test4 Resolution : 0.001 V
    • Diode test4 Accuracy : 2.0% + 3
    • Continuity4 Accuracy : Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
    • Ω4 Range : 600.0 Ω / 6.000 kΩ / 60.00 kΩ
    • Ω4 Resolution : 0.1 Ω / 0.001 kΩ / 0.01 kΩ
    • Ω4 Accuracy : 0.9% + 2 / 0.9% + 1 / 0.9% + 1
    • Capacitance4 Range : 1000 nF / 10.00 μF / 100.0 μF / 9999 μF
    • Capacitance4 Resolution : 1 nF / 0.01 μF / 0.1 μF / 1 μF
    • Capacitance4 Accuracy : 1.9% + 2100 μF - 1000 μF: 1.9% + 21000 μF: 5% + 20
    • Maximum voltage between any terminal and earth ground : 600 V: 600 V
    • Display 3 3/4-digits, 6000 counts, updates 4/sec : 3 3/4-digits, 6000 counts, updates 4/sec
    • Operating temperature : -10°C to 50°C (14°F to 122°F): -10°C to 50°C (14°F to 122°F)
    • Storage temperature : -40°C to 60°C (-22°F to 140°F): -40°C to 60°C (-22°F to 140°F)
    • Temperature coefficient : 0.1 x (specified accuracy) / °C (< 18°C or > 28°C): 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    • Operating altitude 2,000 m : 2,000 m
    • Storage altitude 10,000 m : 10,000 m
    • Relative humidity : 95% to 30°C75% to 40°C45% to 50°C: 95% to 30°C75% to 40°C45% to 50°C
    • Battery type : 9 Volt Alkaline, IEC 6F22: 9 Volt Alkaline, IEC 6F22
    • Battery life : Alkaline: 300 hours typical, without backlight: Alkaline: 300 hours typical, without backlight
    • Size (H x W x L) : 167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in): 167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
    • Weight 13.0 oz (404 g) : 13.0 oz (404 g)
    • Safety : IEC 61010-1: Pollution Degree 2IEC 61010-2-033: CAT IV 600V: IEC 61010-1: Pollution Degree 2IEC 61010-2-033: CAT IV 600V
    • EMI regulations Complies with FCC Part 15, Class B : Complies with FCC Part 15, Class B
    • VCHEK : Input impedance (nominal): ~3 kΩ < 300 pF || Common mode rejection ratio(1 kΩ unbalanced): > 60 dB at DC, 50 or 60 Hz
    • Ω Open circuit test voltage : < 2.7 VDC
    • Ω Full scale voltage : < 0.7 VDC
    • Diode test Open circuit test voltage : 2.7 VDC
    • Diode test Full scale voltage : 2.000 VDC
    • Ω Short circuit current : < 350 μA
    • Diode test Short circuit current : < 1.0 mA