primary_image

Thermoplastic PVC jacket with integral bonding wire 3/8" through 1-1/4" Conduit shall be Anaconda SEALTITE® Type UA. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" thru 1-1/4". Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 3/8" thru 4". Conduit shall be UL listed, CSA certified and IP 67 rated when installed with approved end connectors.

LQT-1/2X100 UA CARTON

ANA34212 34212 714118342128
3.03 / FEET
http://schema.org/OutOfStock
  • Bend Radius: 3.5 in, 88.9 mm
  • Certifications: CSA Certified, RoHS WEEE, UL Listed
  • Conduit Type: UA
  • Inside Diameter: 0.642 in, 16.307 mm
  • Length: 100 ft, 30.48 m
  • Outside Diameter: 0.840 in, 21.336 mm
  • Package Type: Small Cartons
  • Weight: 13.15 kg, 29 lb
QTY
  • Features
  • Specifications
  • NEC Articles
    • Article 250.118 (6) Equipment Grounding
    • Article 300.22 (D) Information Technology Equipment
    • Article 350 Liquid-Tight Flexible Metal Conduit (LFMC)
    • Article 501.10 (B) (2) Class I Div. 2
    • Article 502.10 (A) (2) and (B) (2) Class II Div. 1 & 2
    • Article 503.10 (A) (3) and (B) Class III Div. 1 & 2
    • Article 620.21 Elevator Wiring Methods
    • Article 645.5 (E) (2) Under Raised Floors
  • Installation
    • Conduit used with standard liquid-tight connector for easy installation. IP 67 Rated when installed with approved connectors.
    • Approved for both exposed and concealed locations. Rated for temperature ranges -40ºF to + 176ºF (-40ºC to +80ºC).
    • Approved as an equipment grounding conductor in sizes 3/8" through 1-1/4" if the total grounding path is 6 ft. or less and the circuit conductors are protected by over 20 amps for 3/8" and 1/2" and 60 amps or less for 3/4" through 1-1/4".
    • Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2.
    • Manufactured in a full range of trade sizes from 3/8" through 4".
    • Approved for direct burial and in concrete trade sizes 3/8" through 4".
    • Complies with UL Standard 360 File No. E18917; CSA C22.2 File No. 158897; and NEC Article 350.
  • Application
    • Where UL Listing is Required and Conduit Grounding is Necessary
    • Temperature Range: -40ºF to +176ºF (-40ºC to +80ºC)
  • Specifications
    • Type : UA
    • Electrical Trade Size : 1/2 in (16 mm)
    • Length : 100 ft (30.48 m)
    • Packaging : Small Cartons
    • Inside Diameter : 0.622 to 0.642 in (15.799 to 16.307 mm)
    • Outside Diameter : 0.822 to 0.840 in (20.879 to 21.336 mm)
    • Approx. Inside Bend Radius : 3.5 in (88.9 mm)
    • Approx. Weight per 100 ft : 29 lbs (13.15 kg)
    • Color : Gray
    • Optional Colors : Black
    • Certifications : RoHS WEEE, UL Listed & CSA Certified
    • Cross-Reference # : 21101, 55-08-26-03, 6202-30-00, LA-11, UALT-1/2