AMERICAN POWER CONVERSION CORP

APC Smart-UPS X, Line Interactive, 3kVA, Rack/tower convertible 2U, 100V-127V, 3x 5-15R+3x 5-20R+1x L5-30R NEMA, NMC, Extended runtime [TAA]

SMART-UPS 3KVA RACK/TOWER 2U

APCSMX3KRMLVNCUS SMX3KRMLVNCUS 731304340430
4101.27 / EA
http://schema.org/OutOfStock
  • Depth: 26.26 in, 66.7 cm
  • Height: 3.35 in, 8.5 cm
  • Warranty Length: 2 yr, 3 yr
  • Width: 17.01 in, 43.2 cm
This APC Smart-UPS is designed for IT managers or network administrators to maintain business uptime, data transfer and continuity during prolonged power outages. The 2880VA line interactive 2U rack/tower UPS provides pure sine wave power to support critical electronics during power disruptions. The SMX comes with NEMA L5-30P input, 3x NEMA 5-15R, 3x NEMA 5-20R and 1x NEMA L5-30R outlets. The UPS has a preinstalled Network Management Card for UPS network-based monitoring and management. The Smart-UPS comes with PowerChute Network Shutdown that provides graceful shutdown of physical servers, virtual machines, and HCI clusters. This uninterrupted power supply can connect to EcoStruxure IT or third-party centralized management platforms. The SMX UPS has a 3-year warranty, and the built-in lead-acid battery has a 2-year warranty. This is compatible with dedicated user-replaceable battery, and the APC replacement battery cartridge helps restore UPS performance to the original specifications. The Smart-UPS comes with a pair of tower-mounting stabilizing feet and rack-mounting brackets. It comes with APC temperature sensor AP9335T for monitoring temperature. The 3 switchable outlet groups allow more granular management of the power supplied to your devices. The Emergency Power Off feature enables the UPS to remotely shutdown during emergencies. The UPS is TAA Complaint.
QTY
  • Features
  • Specifications
  • Features
    • StruxureWare Data Center Expert compatible — Enables centralized management via StruxureWare Data Center Expert.
    • Predictive failure notification. — Provides early-warning fault analysis ensuring proactive component replacement.
    • Wide input voltage range — Designed for harsh electrical environments to save battery life.
    • LED Indicators — Provide easy-to-read status of the unit and utility power conditions.
    • Overload protection — Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
    • Network manageable — Provides remote power management of the UPS over the network.
    • Boost and Trim Automatic Voltage Regulation (AVR) — Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
    • Serial connectivity — Provides management of the UPS via a serial port.
    • High online efficiency — Reduces utility costs, generates less heat.
    • Green mode — Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
    • High frequency design — Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
    • Energy meter — Provides actual kilowatt hours of usage for energy conscious users.
    • Predictive replace battery date — Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
    • Intuitive LCD interface — Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
    • Auto recognition of external batteries — UPS recognizes when external battery packs are attached and automatically adjusts runtime.
    • Multiple switched outlet groups — Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
    • Pure sine wave output on battery — Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
    • Disconnected battery notification — Warns when a battery is not available to provide backup power.
    • Load shedding — Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).
    • Sequenced network shutdown and reboot — Customize network shutdown and reboot sequence of connected servers and UPSs.
    • Outlet group control — Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
    • Scalable runtime — Allows additional run time to be quickly added as needed.
    • Adjustable voltage sensitivity — Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
    • Adjustable voltage-transfer points — Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
    • Audible alarms — Provides notification of changing utility power and UPS power conditions
    • Automatic restart of loads after UPS shutdown — Automatically starts up the connected equipment upon the return of utility power.
    • Automatic self-test — Periodic battery self-test ensures early detection of a battery that needs to be replaced.
    • Cold-start capable — Provides temporary battery power when the utility power is out.
    • Hot-swappable batteries — Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
    • Power conditioning — Protects connected loads from surges, spikes, lightning, and other power disturbances.
    • Battery failure notification — Provides early-warning fault analysis on batteries enabling timely preventive maintenance
    • Rack/Tower convertible — Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
    • Safety-agency approved — Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
    • SmartSlot — Customize UPS capabilities with management cards.
    • Temperature-compensated battery charging — Prolongs battery life by regulating the charge voltage according to battery temperature.
    • USB connectivity — Provides management of the UPS via a USB port (not available on all models).
    • User-replaceable batteries — Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
    • Intelligent battery management — Maximizes battery performance, life, and reliability through intelligent, precision charging.
    • Frequency and voltage regulation — Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • What's in the box?
    • CD with software
    • Documentation CD
    • Installation guide
    • Rack mounting hardware
    • Rack Mounting brackets
    • Rack Mounting support rails
    • Removable support feet
    • Smart UPS signalling RS-232 cable
    • USB cable
    • Web/SNMP Management Card
  • Conformance
    • Approvals : BSMI, CSA, NOM, TAA compliance, TÜV, VCCI Class A
    • EquipmentProtectionPolicy : Lifetime : $150000
    • Compliance : TAA
  • Battery
    • ReplacementBattery : APCRBC117US
    • TypicalRechargeTime : 3 h
    • BatteryType : Lead-Acid battery
  • Sustainability
    • Rohs : Compliant with Exemptions
    • Reach : Reference contains Substances of Very High Concern above the threshold
    • OptimizedEnergyEfficiency : Energy efficient product
    • TakeBack : Yes
    • MercuryFree : Yes
  • Weight, Height, Width, Depth
    • Weight : 84.77 lb(US) (38.45 kg)
    • Height : 3.35 in (8.5 cm) in
    • Width : 17.01 in (43.2 cm) in
    • Depth : 26.26 in (66.7 cm) in
  • Physical
    • ProductOrientation : lower
    • RackHeight : 2U
    • Color : Black
    • SurgeEnergyRating : 540 J
    • MountPosition : front
  • Input
    • CordLength : 8 ft (2.44 m)
    • InputConnectionType : NEMA L5-30P
    • InputVoltage : 120 V
    • MaximumInputCurrent : 15 A
  • Output
    • OutputPowerCapacity : 2880 VA
    • OutputConnections : 3 NEMA 5-15R, 3 NEMA 5-20R, 1 NEMA L5-30R
    • NominalOutputVoltage : 120 V
    • Topology : Line Interactive
    • Waveformtype : Sine wave
  • Warranty
    • Warranty : 3 years repair or replace (excluding battery) and 2 years for battery, optional extended warranties available, optional on-site warranties available