3M™ Cold Shrink QT-III Termination Kit 7694-S-4, Tape, Wire, UniShield®,5-25/28 kV, Insulation OD 0.83-1.53 in, 4 Skirt, 3/kit

15KV 4/0 TO 500 COLD SHRINK

MMM7694S4 7694-S-4 054007422136
1461.94 / Kit
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Indoor/Outdoor: Outdoor Skirted
  • Insulation Diameter Range: 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm
  • Number of Conductors: 1
  • Shielding Type: Tape Shield, UniShield®, Wire Shield
  • Voltage: 15 kV, 25/28 kV, 28 kV, 5 kV, 8 kV
  • Voltage Application: Medium Voltage
3M™ Cold Shrink QT III 7620 S, 7680 S & 7690 S Series Termination Kit includes three 1 piece, 3 phase, skirted terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 35kV.
QTY
  • Product Description
  • Features
  • Specifications
3M™ Cold Shrink QT III 7620 S, 7680 S & 7690 S Series Termination Kit includes three 1 piece, 3 phase, skirted terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 35kV.
  • Features
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor applications
    • Silicone rubber insulation offers durability and reduces leakage currents in damp conditions
  • Specifications
    • Manufacturer Catalog Number : 7000006121
    • Breakout Boot : No
    • Cable Insulation Outside Diameter Range (Metric) : 0.83-1.53 in
    • Cable Shielding : Wire Shield|| Tape Shield|| UniShield®
    • Conductor Size by Voltage : (5 kV) 500-750 kcmil, (8 kV) 350-700 kcmil, (15 kV) 4/0 AWG-500 kcmil, (25/28 kV) 2/0 AWG-250 kcmil
    • Indoor/Outdoor : Outdoor Skirted
    • Insulation Level : 100%|| 133%
    • Insulation Outer Diameter (Imperial) : 0.83 in|| 0.92 in|| 0.85 in|| 0.86 in|| 0.87 in|| 0.88 in|| 0.89 in|| 0.9 in|| 0.91 in|| 1 in|| 0.93 in|| 0.94 in|| 0.95 in|| 0.96 in|| 0.97 in|| 0.98 in|| 0.99 in|| 1.01 in|| 1.17 in|| 1.02 in|| 1.03 in|| 1.04 in|| 1.05 in|| 1.06 in|| 1.07 in|| 1.08 in|| 1.09 in|| 1.1 in|| 1.11 in|| 1.12 in|| 1.13 in|| 1.14 in|| 1.15 in|| 1.16 in|| 0.84 in|| 1.18 in|| 1.2 in|| 1.28 in|| 1.21 in|| 1.22 in|| 1.23 in|| 1.24 in|| 1.25 in|| 1.26 in|| 1.27 in|| 1.36 in|| 1.29 in|| 1.3 in|| 1.31 in|| 1.32 in|| 1.33 in|| 1.34 in|| 1.35 in|| 1.37 in|| 1.19 in|| 1.38 in|| 1.39 in|| 1.4 in|| 1.41 in|| 1.42 in|| 1.43 in|| 1.44 in|| 1.45 in|| 1.46 in|| 1.47 in|| 1.48 in|| 1.49 in|| 1.5 in|| 1.51 in|| 1.52 in|| 1.53 in
    • Insulation Outer Diameter (Metric) : 21.082 mm|| 23.368 mm|| 21.59 mm|| 21.844 mm|| 22.098 mm|| 22.352 mm|| 22.606 mm|| 22.86 mm|| 23.114 mm|| 25.4 mm|| 23.622 mm|| 23.876 mm|| 24.13 mm|| 24.384 mm|| 24.638 mm|| 24.892 mm|| 25.146 mm|| 25.654 mm|| 29.718 mm|| 25.908 mm|| 26.162 mm|| 26.416 mm|| 26.67 mm|| 26.924 mm|| 27.178 mm|| 27.432 mm|| 27.686 mm|| 27.94 mm|| 28.194 mm|| 28.448 mm|| 28.702 mm|| 28.956 mm|| 29.21 mm|| 29.464 mm|| 21.336 mm|| 29.972 mm|| 30.48 mm|| 32.512 mm|| 30.734 mm|| 30.988 mm|| 31.242 mm|| 31.496 mm|| 31.75 mm|| 32.004 mm|| 32.258 mm|| 34.544 mm|| 32.766 mm|| 33.02 mm|| 33.274 mm|| 33.528 mm|| 33.782 mm|| 34.036 mm|| 34.29 mm|| 34.798 mm|| 30.226 mm|| 35.052 mm|| 35.306 mm|| 35.56 mm|| 35.814 mm|| 36.068 mm|| 36.322 mm|| 36.576 mm|| 36.83 mm|| 37.084 mm|| 37.338 mm|| 37.592 mm|| 37.846 mm|| 38.1 mm|| 38.354 mm|| 38.608 mm|| 38.862 mm
    • Insulation Rejacketing : No
    • Lug/Stem Connector Included in Kit : No
    • Manufacturing Origin : USA
    • Maximum Installed Length : 12.25 in
    • Number of Conductors : 1
    • Number of Skirts : 4
    • Voltage : 15 kV|| 25/28 kV|| 28 kV|| 5 kV|| 72.5 kV|| 8 kV
    • Voltage Application : Medium Voltage