3M™ Cold Shrink QT-III Termination Kit 7622-T-110, Tape/Wire/UniShield® Shielding, 5-15 kV, Insulation OD 0.64-1.08 in, 3/kit

3M™ Cold Shrink QT-III Termination Kit 7622-T-110, Tape/Wire/UniShield® Shielding, 5-15 kV, Insulation OD 0.64-1.08 in, 3/kit

MMM7622T110 7622-T-110 054007417606
425.87 / Kit
3M™ Cold Shrink QT-III Silicone Rubber Termination Kit 7620-T and 7690-T Series contains one-piece, non-skirted, silicone rubber terminations, meets IEEE Standard 48 Class 1 for indoor and weather-protected applications. The kits are designed for terminating solid dielectric shielded power cable rated 5–35 kV, with tape shield, wire shield and UniShield® constructions.
  • Features
  • Product Description
  • Specifications
  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
  • Non-tracking, molded, silicone rubber insulation offers durability
  • Includes 3 non-skirted, 1-piece, 3-phase, cold shrink terminations
  • Suitable for indoor applications
  • High dielectric-constant material regulates the distribution of electric field stress
3M™ Cold Shrink QT-III Silicone Rubber Termination Kit 7620-T and 7690-T Series contains one-piece, non-skirted, silicone rubber terminations, meets IEEE Standard 48 Class 1 for indoor and weather-protected applications. The kits are designed for terminating solid dielectric shielded power cable rated 5–35 kV, with tape shield, wire shield and UniShield® constructions.
  • Maximum Installed Length : 12.00 in
  • Voltage Application : Medium Voltage
  • Family : QT-III
  • Lug/Stem Connector Included in Kit : No
  • Indoor/Outdoor : Indoor Non-skirted
  • Number of Conductors : 1
  • Insulation Level : 133% - 100%
  • Insulation Rejacketing : No
  • RoHS EU Comments : Contact 3M for information
  • Insulation Outer Diameter (Imperial) : 0.79 in - 0.74 in - 0.83 in - 0.72 in - 0.88 in - 0.98 in - 0.93 in - 1.01 in - 0.68 in - 0.75 in - 0.8 in - 0.97 in - 1.07 in - 0.95 in - 0.66 in - 0.96 in - 0.76 in - 1.08 in - 1.05 in - 0.7 in - 0.82 in - 0.84 in - 0.71 in - 0.94 in - 0.78 in - 0.85 in - 0.81 in - 0.77 in - 0.73 in - 0.92 in - 0.69 in - 1.03 in - 0.99 in - 0.91 in - 0.9 in - 0.65 in - 1.02 in - 0.87 in - 0.67 in - 0.89 in - 1.04 in - 0.64 in - 1.06 in - 1 in - 0.86 in
  • Conductor Sizes : 400 kcmil - 1/0 AWG - 2 AWG - 350 kcmil - 300 kcmil - 3/0 AWG - 1 AWG - 2/0 AWG - 4/0 AWG - 250 kcmil
  • Breakout Boot : No
  • Voltage : 5 kV - 15 kV - 8 kV
  • Cable Insulation Outside Diameter Range : 0.64-1.08 in
  • Cable Insulation Outside Diameter Range (Metric) : 16.3-27.4 mm
  • Conductor Size by Voltage : (5 kV) 4/0 AWG-400 kcmil, (8 kV) 3/0 AWG-300 kcmil, (15 kV) 2-4/0 AWG
  • Product Technology : Cold Shrink
  • Cable Shielding : UniShield® - Wire Shield - Tape Shield
  • BIL : 110 kV
  • Insulation Outer Diameter (Metric) : 25.4 mm - 27.432 mm - 26.924 mm - 25.654 mm - 22.86 mm - 21.59 mm - 25.908 mm - 16.764 mm - 23.368 mm - 26.67 mm - 24.13 mm - 20.574 mm - 18.034 mm - 18.796 mm - 17.018 mm - 26.162 mm - 19.558 mm - 24.892 mm - 17.272 mm - 23.622 mm - 26.416 mm - 19.812 mm - 27.178 mm - 22.606 mm - 20.32 mm - 17.78 mm - 16.256 mm - 19.05 mm - 20.828 mm - 23.114 mm - 18.542 mm - 19.304 mm - 16.51 mm - 21.844 mm - 20.066 mm - 18.288 mm - 24.384 mm - 22.352 mm - 25.146 mm - 24.638 mm - 21.082 mm - 23.876 mm - 22.098 mm - 17.526 mm - 21.336 mm