Electronic VAR control - 120 A 380..480 V AC - IP00 enclosure

AccuSine PFV+ 120A 380-480 VAC

SQDEVCP120D5IP00 EVCP120D5IP00 3606480851551
74364.56 / EA
http://schema.org/OutOfStock
  • Certifications: ABS, CE, CULus, DNV-GL, RCM
  • Depth: 384 mm
  • Height: 1400 mm
  • Net Weight: 110 kg
  • Standard: CSA C22.2 No 14, CSA C22.2 No 60947-1-07, EN 60439-1, EN 61000-6-4, UL 508, UL 60947-1
  • Storage Temperature: -20-60 °C
  • Warranty Length: 18 mth
  • Width: 421 mm
This hardware is an active power correction solution, from AccuSine familly, to help stabilize electrical networks by providing swift power factor correction and load balancing. It is specifically designed for harsh electrical conditions, for heavy industrial applications including mission critical environments. This version is UL Type OPEN, or ingress protection IP00, and can be connected on Low Voltage networks rated 380 Volt to 480 Volt. It is specified for a standard Root Mean Square output current rating of 120 Amps. The enclosure is wall mounted, allow cable entry from bottom and is delivered in RAL7035 light grey. This active power filter which achieves above standards performance is certified to CE, UL, IBC 2015 AC156, EAC, RCM. And is designed to IEC 62477-1, IEC 61000-6-2, IEC 61000-6-4, IEC 61439-1, UL508 and IEEE 519-2014. Up to 10 units of different ratings can be paralleled, to achieve a maximum VAR injection of 2500 kVar either leading or lagging per current transformer set. Frame exterior dimensions are 421 millimetres in width, 384 millimetres in depth, 1400 millimetres in height and product weight 113 kg.
QTY
  • Product Description
  • Specifications
This hardware is an active power correction solution, from AccuSine familly, to help stabilize electrical networks by providing swift power factor correction and load balancing. It is specifically designed for harsh electrical conditions, for heavy industrial applications including mission critical environments. This version is UL Type OPEN, or ingress protection IP00, and can be connected on Low Voltage networks rated 380 Volt to 480 Volt. It is specified for a standard Root Mean Square output current rating of 120 Amps. The enclosure is wall mounted, allow cable entry from bottom and is delivered in RAL7035 light grey. This active power filter which achieves above standards performance is certified to CE, UL, IBC 2015 AC156, EAC, RCM. And is designed to IEC 62477-1, IEC 61000-6-2, IEC 61000-6-4, IEC 61439-1, UL508 and IEEE 519-2014. Up to 10 units of different ratings can be paralleled, to achieve a maximum VAR injection of 2500 kVar either leading or lagging per current transformer set. Frame exterior dimensions are 421 millimetres in width, 384 millimetres in depth, 1400 millimetres in height and product weight 113 kg.
  • Environment
    • Product Certifications : cULus || DNV-GL || CE || ABS || RCM
    • Height : 1400 mm
    • Standards : CSA C22.2 No 60947-1-07 || UL 508 || EN 61000-6-4 || UL 60947-1 || CSA C22.2 No 14 || EN 60439-1
    • Ambient Air Temperature For Operation : 0-40 °C || 0-50 °C maximum with current derating of 2 % per °C
    • Environmental Characteristic : operating 3C2 IEC 60721-3-3 || operating 3S2 IEC 60721-3-3 || storage 3C3 IEC 60721-3-3 || storage 3S3 IEC 60721-3-3
    • Net Weight : 110 kg
    • Impregnation Material : conformal coated
    • Relative Humidity : 0-95 %
    • Ambient Air Temperature For Storage : -20-60 °C
    • Operating Altitude : <= 3280.84 ft (1000 m) 1 % per 100 m
    • Color : Light gray RAL 7035)
    • Width : 421 mm
    • Depth : 384 mm
    • Ip Degree Of Protection : IP00
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Eu Rohs Directive : Compliant
  • Complementary
    • Accessibility For Operation : front
    • Reactive Power Rating : 100 kvar 480 V AC 50/60 Hz
    • Network Rated Voltage : 380-480 V AC
    • Operating Mode : power factor correction || volt-var support || mains current balancing
    • Mounting Location : indoor
    • Electromagnetic Compatibility : conducted EMC, class A EN 61000-6-4
    • Function Available : rear plenum with forced ventilation for high heat flow
    • Input Frequency : 50/60 Hz +/- 3 % auto-sensing
    • Enclosure Mounting : wall mounted
    • Nominal Output Current : 120 A
    • Poles Description : 3P
    • Protection Type : without protection
    • Location Of Connection : bottom
    • Maximum Permissible Voltage : 1.1 x Un
    • Wiring Mode : 3 or 4 wires
  • Specifications
    • Range Of Product : AccuSine
    • Product Or Component Type : electronic VAR controller
    • Product Name : AccuSine PFV+