• Features
  • Specifications
  • Key Features
    • Ideal for quick verifications and field service
    • Min/Max/Average to record signal fluctuations
    • CAT III 600V
    • The 115 digital multimeter is for electrical and electronic testing in field service, industrial and applications where more than the basic functions are needed.
  • Other Useful Features
    • Ideal for quick verifications and field service
    • Presents a large white LED backlight for working in poorly lit areas
    • Measures AC and DC voltage to 600V
    • Measures AC and DC current to 10A (20 A overload for 30-seconds max)
    • Measures resistance, continuity, frequency, and capacitance
    • Provides Min/Max/Average with elapsed time to record signal fluctuations
    • Comes with a holster with probe holders for easy storage
    • Features a compact ergonomic design for one-handed operation
    • Fits into optional ToolPak™ magnetic hanger for hands-free operation
    • CAT III 600 V safety rated
    • For field service technicians, basic electronic repair.
    • Holster
    • Installed 9V battery
    • 4 mm silicone test lead set
    • User manual - 2019 BEST PRODUCT IN CATEGORY
  • Product Overview
    • A compact trms digital multimeter for field service technicians
    • The Fluke 115 technicians digital multimeter is the compact, general purpose troubleshooting tool for field service technicians. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications.
    • The Fluke 110 Series has five true-rms digital multimeters, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy-to-read digits.
    • General purpose digital multimeter for electrical and electronic testing
    • Includes:
  • Specifications
    • DC millivolts Range/resolution : 600.0 mV / 0.1 mV
    • DC millivolts Accuracy : ± ([% of reading] + [counts]): 0.5% + 2
    • DC volts Range/resolution : 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V
    • DC volts Accuracy : ± ([% of reading] + [counts]): 0.5% + 2
    • AC millivolts1True RMS Range/resolution : 600.0 mV / 0.1 mV
    • AC millivolts1True RMS Accuracy : 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
    • AC volts1True RMS Range/resolution : 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V
    • AC volts1True RMS Accuracy : 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
    • Continuity Range/resolution : 600 Ω / 1 Ω
    • Continuity Accuracy : Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer.
    • Ohms Range/resolution : 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ || 40.00 MΩ / 0.01 MΩ
    • Ohms Accuracy : 0.9% + 1 || 5% + 2
    • Diode test Range/resolution : 2.00 V / 0.001 V
    • Diode test Accuracy : 0.9% + 2
    • Capacitance Range/resolution : 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF || > 1000 μF
    • Capacitance Accuracy : 1.9% + 2 || 5% + 20%
    • Lo-Z capacitance Range : 1 nF to 500 μF
    • Lo-Z capacitance Accuracy : 10% + 2 typical
    • AC amps True RMS(45 Hz to 500Hz) Range/resolution : 6.000 A / 0.001 A10.00 A / 0.01 A
    • AC amps True RMS(45 Hz to 500Hz) Accuracy : 1.5% + 320 A overload for 30-seconds max
    • DC amps Range/resolution : 6.000 A / 0.001 A10.00 A / 0.01 A
    • DC amps Accuracy : 1.0% + 320 A overload for 30-seconds max
    • Hz (V or A input)2 Range/resolution : 99.99 Hz / 0.01 Hz999.9 Hz / 0.01 Hz9.999 kHz / 0.001 kHz50.00 kHz / 0.01 kHz
    • Hz (V or A input)2 Accuracy : 0.1% + 2