SQUARE D

Panelboard interior, NF, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 480Y/277 VAC bolt on, J Frame

PNLBD INT NF CW 225A J M/B 42C

SQDNF8442M2JDC NF8442M2JDC 785901915881
6126.15 / EACH
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Enclosure Depth: 5.65 in
  • Enclosure Height: 85 in
  • Enclosure Width: 8.625 in
  • Height: 71 in, 85 in
  • Number of Spaces: 42
  • Warranty Length: 18 mth
  • Width: 10.44 in, 8.625 in
With bus capacities from 125-800A, NF panelboards offer a wide variety of field installable circuit breakers and accessories, including 200% neutrals.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Standards : CSA || UL
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1404020EN
    • Packaging Without Single Use Plastic : No
    • Toxic Heavy Metal Free : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Circularity Profile : N/A
    • Take-Back : No
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 718.5271140483
  • Complementary
    • Height : 71 in
    • Phase : 3 phase 4 wires
    • Tightening Torque : 4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AWG 4...300 kcmil)
    • [Iu] Rated Interrupted Current : 65 kA
    • Number Of Spaces : 42
    • Enclosure Nominal Height : 85 in
    • Enclosure Nominal Depth : 5.65 in NEMA 1
    • Line Rated Current : 225 A
    • Width : 10.44 in
    • Enclosure Nominal Width : 8.625 in
    • [Ue] Rated Operational Voltage : 600Y/347 V AC
  • Specifications
    • Country of Origin : United States
    • Width : 8.625 in
    • Height : 85 in
    • Circuit Breaker Type : EDB/EDG/EDJ
    • Material : copper
    • Load Center Type : main breaker