Panelboard interior, NF, main lugs, 125A, Cu bus, 30 pole spaces, 3 phase, 4 wire, 480Y/277 VAC bolt on

PNLBD INT NF CW 125A MLO 30CKT

SQDNF8430L1C NF8430L1C 785901714767
2557.20 / EACH
http://schema.org/OutOfStock
  • Enclosure Depth: 5.65 in
  • Enclosure Height: 59 in
  • Enclosure Width: 8.625 in
  • Height: 27 in, 59 in
  • Number of Spaces: 30
  • Warranty Length: 18 mth
  • Width: 10.44 in, 8.625 in
NF Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These interiors provide protection for commercial and industrial applications. NF Panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. NF Panelboards are field convertible to top or bottom feed. NF Panelboards are convertible from main lug to main breaker. NF Panelboards can provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. The main lugs are rated at 100A 480Y/277 VAC 3 phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 30 spaces and has a copper bus bar. Interior is for EDB, EDG, and EDJ branch circuit breakers. Line lug connections will accept 6 AWG to 300 kcmil copper or aluminum wire. The interior is 27 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
NF Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These interiors provide protection for commercial and industrial applications. NF Panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. NF Panelboards are field convertible to top or bottom feed. NF Panelboards are convertible from main lug to main breaker. NF Panelboards can provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. The main lugs are rated at 100A 480Y/277 VAC 3 phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 30 spaces and has a copper bus bar. Interior is for EDB, EDG, and EDJ branch circuit breakers. Line lug connections will accept 6 AWG to 300 kcmil copper or aluminum wire. The interior is 27 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Standards : UL 67 || CSA C22.2
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : No
    • Mercury Free : Yes
    • Packaging Without Single Use Plastic : No
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Take-Back : No
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Height : 27 in
    • Phase : 3 phase 4 wires
    • Connections - Terminals : lug line AWG 6...300 kcmil aluminium/copper || lug neutral AWG 6...300 kcmil aluminium/copper
    • Tightening Torque : 4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AWG 4...300 kcmil)
    • [Iu] Rated Interrupted Current : 65 kA
    • Number Of Spaces : 30
    • Enclosure Nominal Height : 59 in
    • Enclosure Nominal Depth : 5.65 in NEMA 1
    • Line Rated Current : 100 A
    • Width : 10.44 in
    • Enclosure Nominal Width : 8.625 in
    • [Ue] Rated Operational Voltage : 600Y/347 V AC
  • Specifications
    • Country of Origin : Mexico
    • Width : 8.625 in
    • Height : 59 in
    • Circuit Breaker Type : EDB/EDG/EDJ
    • Material : copper
    • Load Center Type : main lugs