  • Certifications: UL Listed File E-6294
  • Depth: 115 mm
  • Enclosure Material: Steel
  • Height: 758 mm
  • Line Rated Current: 200 A
  • Material: Tin Plated Aluminium: Busbar
  • Number of Circuits: 16
  • Number of Phases: 1
  • Short Circuit Current: 22 kA
  • Width: 375 mm
The Homeline load center offer features Homeline circuit breakers, ground fault circuit breakers and arc fault interrupters. Homeline load centers enable the use of a full complement of accessories. Systems are single phase and are rated for indoor use or are rain proof. Homeline load centers are designed for residential and industrial use to protect electrical systems, equipment and people. This Homeline load center has a two pole plug on neutral main supply circuit breaker that is rated at 200A 120/240 VAC single phase. Homeline load center provides a 22 kA breaking capacity. This system provides 8 spaces in a NEMA 3R rain proof enclosure. The electrical connections are feed thru lugs. The lugs will accept a wire range of 4 AWG to 250 kcmil copper or aluminum wire. This Homeline load center has a height of 29.84 inches, a width of 14.76 inches, and depth of 4.52 inches. Homeline load centers are UL Listed.
QTY
  • Product Description
  • Specifications
The Homeline load center offer features Homeline circuit breakers, ground fault circuit breakers and arc fault interrupters. Homeline load centers enable the use of a full complement of accessories. Systems are single phase and are rated for indoor use or are rain proof. Homeline load centers are designed for residential and industrial use to protect electrical systems, equipment and people. This Homeline load center has a two pole plug on neutral main supply circuit breaker that is rated at 200A 120/240 VAC single phase. Homeline load center provides a 22 kA breaking capacity. This system provides 8 spaces in a NEMA 3R rain proof enclosure. The electrical connections are feed thru lugs. The lugs will accept a wire range of 4 AWG to 250 kcmil copper or aluminum wire. This Homeline load center has a height of 29.84 inches, a width of 14.76 inches, and depth of 4.52 inches. Homeline load centers are UL Listed.
  • Complementary
    • Height : 758 mm
    • Bus Rated Current : 225.0 A
    • Phase : 1 phase
    • Short-Circuit Current : 22 kA
    • Number Of Tandem Circuit Breakers : 8
    • Material : tin plated aluminium: busbar
    • Surface Finish : baked enamel Gray
    • Enclosure Material : welded galvannealed steel
    • Awg Gauge : AWG 4...250 kcmil copper or aluminium
    • Width : 375 mm
    • Wiring Configuration : 3-wire
    • Depth : 115 mm
    • Device Composition : grounding bar (ordered separately)
    • Box Number : 6R
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1403002
    • Sustainable Offer Status : Green Premium product
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Circularity Profile : N/A
    • Eu Rohs Directive : Compliant
  • Environment
    • Product Certifications : UL listed file E-6294
    • Ambient Air Temperature For Operation : -5 °C || 40 °C
  • Specifications
    • Range Of Product : Homeline
    • Provided Equipment : circuit-breaker 1 ) 2P 200 A 120/240 V AC main supply ready assembled
    • Product Or Component Type : Load Center
    • Number Of Circuits : 16
    • Number Of Spaces : 8
    • Nema Degree Of Protection : NEMA 3R outdoor
    • Cover Type : surface cover
    • Line Rated Current : 200 A
    • Load Center Type : PoN Convertible Mains (breaker)