Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m

CODED MAGNETIC SWITCH, TELEMEC

SQDXCSDMP59010 XCSDMP59010 T3389119013000
154.33 / EA
http://schema.org/OutOfStock
  • Cable Length: 10 m
  • Certifications: CSA, UL
  • Contact Material: Rhodium
  • Depth: 13 mm
  • Enclosure Material: Thermoplastic
  • Height: 88 mm
  • Material: Plastic
  • Net Weight: 0.18 kg
  • Number of Poles: 2
  • Operating Temperature: -25-85 °C
  • Standard: CSA C22.2 No 14, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 12100, ISO 14119, UL 508
  • Storage Temperature: -40-85 °C
  • Warranty Length: 18 mth
  • Width: 25 mm
QTY
  • Specifications
  • Specifications
    • Range Of Product : Telemecanique Safety switches XCS
    • [Ue] Rated Operational Voltage : 24 V DC
    • Cable Length : 10 m
    • Product Or Component Type : coded magnetic switch
    • Component Name : XCSDMP
    • Design : rectangular, standard
    • Material : plastic
    • Size : 88 x 25 x 13 mm
    • Contacts Type And Composition : 1 NC + 1 NO
    • Contact Operation : staggered
    • Electrical Connection : pre-cabled
    • Cable Composition : 4 x 0.25 mm²
    • Approach Directions : 3 directions
    • [Ui] Rated Insulation Voltage : 100 V DC
    • Number Of Poles : 2
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Maximum [Ie] Rated Operational Current : 100 mA
    • Height : 88 mm
    • Switching Frequency : 150 Hz
    • Short-Circuit Protection : 500 mA external cartridge fuse gG (gl)
    • Switching Capacity In Ma : 0.1...100 mA
    • [Sar] Assured Tripping Distance : 20 mm
    • Contacts Material : rhodium
    • Insulation Resistance : 1000 MOhm
    • Resistance Across Terminals : 10 Ohm
    • Net Weight : 0.18 kg
    • [Uimp] Rated Impulse Withstand Voltage : 2.5 kV EN/IEC 60947-5-1
    • Maximum Switching Voltage : 100 V DC
    • [Sa] Assured Operating Distance : 8 mm
    • Cable Material : PVC
    • Breaking Capacity : 10 VA
    • Safety Reliability Data : B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
    • Enclosure Material : thermoplastic PBT
    • Width : 25 mm
    • Depth : 13 mm
    • Electrical Durability : 1200000 cycles
    • Safety Level : can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Product Certifications : CSA || UL
    • Ambient Air Temperature For Operation : -25-85 °C
    • Standards : CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/IEC 60204-1 || UL 508 || ISO 14119 || EN/ISO 12100
    • Shock Resistance : 30 gn 11 ms IEC 60068-2-27
    • Vibration Resistance : 10 gn 10-150 Hz)IEC 60068-2-6
    • Ip Degree Of Protection : IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
    • Ambient Air Temperature For Storage : -40-85 °C
    • Electrical Shock Protection Class : class II EN/IEC 61140
    • Maximum Sensitivity To Magnetic Fields : 0.3 mT
    • Protective Treatment : TH