Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 1 NC+1 NO, staggered, cable 30 m

CODED MAGNETIC SWITCH, TELEMEC

SQDXCSDMC59030EX T3389119048279
125.79 / EA
http://schema.org/OutOfStock
  • Cable Length: 30 m
  • Certifications: INERIS 07ATEX0036
  • Contact Material: Rhodium
  • Enclosure Material: Thermoplastic
  • Material: Plastic
  • Net Weight: 0.101 kg
  • Number of Poles: 2
  • Operating Temperature: -25-85 °C
  • Standard: EN 60079-0, EN 60079-11, EN 60079-18, EN 60079-31, EN/ISO 13849-1
  • Storage Temperature: -40-85 °C
QTY
  • Specifications
  • Specifications
    • Range Of Product : Telemecanique Safety switches XCS
    • Cable Length : 30 m
    • Product Or Component Type : coded magnetic switch
    • Design : rectangular, compact
    • Material : plastic
    • Size : 51 x 16 x 7 mm
    • Contacts Type And Composition : 1 NC + 1 NO
    • Contact Operation : staggered
    • Electrical Connection : pre-cabled
    • Cable Composition : 4 x 0.25 mm²
    • Device Short Name : XCSDMC
    • Number Of Poles : 2
  • Complementary
    • Maximum [Ie] Rated Operational Current : 100 mA
    • Switching Frequency : 150 Hz
    • Short-Circuit Protection : 500 mA external cartridge fuse gG (gl)
    • [Ue] Rated Operational Voltage : 24 V DC
    • Switching Capacity In Ma : 0.1...100 mA
    • [Sar] Assured Tripping Distance : 15 mm
    • Contacts Material : rhodium
    • Insulation Resistance : 1000 MOhm
    • Resistance Across Terminals : 10 Ohm
    • Net Weight : 0.101 kg
    • [Uimp] Rated Impulse Withstand Voltage : 2.5 kV EN/IEC 60947-5-1
    • Maximum Switching Voltage : 100 V DC
    • [Sa] Assured Operating Distance : 5 mm
    • Breaking Capacity : 10 VA
    • Approach Directions : 3 directions
    • Electrical Durability : 1200000 cycles
    • [Ui] Rated Insulation Voltage : 100 V DC
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Product Certifications : INERIS 07ATEX0036
    • Ambient Air Temperature For Operation : -25-85 °C
    • Standards : EN 60079-0 || EN 60079-11 || EN 60079-18 || EN 60079-31 || EN/ISO 13849-1
    • Dust Zone : according to protection mode mD, tD and ia || zone 0 - 1 - 2/20 - 21 - 22
    • Shock Resistance : 30 gn 11 ms IEC 60068-2-27
    • Vibration Resistance : 10 gn 10-150 Hz)IEC 60068-2-6
    • Ip Degree Of Protection : IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
    • Directives : 2014/34/EU - ATEX directive
    • Ambient Air Temperature For Storage : -40-85 °C
    • Cable Material : PVC
    • Electrical Shock Protection Class : class II IEC 60536
    • Safety Reliability Data : B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
    • Maximum Sensitivity To Magnetic Fields : 0.3 mT
    • Enclosure Material : thermoplastic PBT
    • Protective Treatment : TH
    • Safety Level : can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508