Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 1 NC + 1 NO, staggered, M8 0.15 m

CODED MAGNETIC SWITCH XCSDMC -

SQDXCSDMC590L01M8 T3389118000209
149.56 / EA
http://schema.org/OutOfStock
  • Cable Length: 0.15 m
  • Certifications: CSA, UL
  • Contact Material: Rhodium
  • Depth: 7 mm
  • Enclosure Material: Thermoplastic
  • Height: 51 mm
  • Material: Plastic
  • Net Weight: 0.101 kg
  • Number of Poles: 2
  • Operating Temperature: -25-85 °C
  • Standard: CSA C22.2 No 14, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 12100, ISO 14119, UL 508
  • Storage Temperature: -40-85 °C
  • Warranty Length: 18 mth
  • Width: 16 mm
This XCSDMC Coded Magnetic Safety Switch is designed for use as a safety interlock switch for guard door or protective casings monitoring and position detection on machines with low inertia. It has 1 normally open and 1 normally closed staggered contact in presence of magnet. It has a compact rectangular design with a 15 centimeter PVC cable connection, allowing for flexible installation. Its B10D reliability data is 50 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
QTY
  • Product Description
  • Specifications
This XCSDMC Coded Magnetic Safety Switch is designed for use as a safety interlock switch for guard door or protective casings monitoring and position detection on machines with low inertia. It has 1 normally open and 1 normally closed staggered contact in presence of magnet. It has a compact rectangular design with a 15 centimeter PVC cable connection, allowing for flexible installation. Its B10D reliability data is 50 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
  • Specifications
    • Range Of Product : Telemecanique Safety switches XCS
    • [Ue] Rated Operational Voltage : 24 V DC
    • Cable Length : 0.15 m
    • Product Or Component Type : coded magnetic switch
    • Component Name : XCSDMC
    • Design : rectangular, compact
    • Material : plastic
    • Size : 51 x 16 x 7 mm
    • Connector Type : M8
    • Contacts Type And Composition : 1 NC + 1 NO
    • Contact Operation : staggered
    • Electrical Connection : connector on flying lead
    • Approach Directions : 3 directions
    • [Ui] Rated Insulation Voltage : 100 V DC
    • Number Of Poles : 2
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Maximum [Ie] Rated Operational Current : 100 mA
    • Height : 51 mm
    • Switching Frequency : 150 Hz
    • Short-Circuit Protection : 500 mA external cartridge fuse gG (gl)
    • Switching Capacity In Ma : 0.1...100 mA
    • [Sar] Assured Tripping Distance : 15 mm
    • Contacts Material : rhodium
    • Insulation Resistance : 1000 MOhm
    • Resistance Across Terminals : 10 Ohm
    • Net Weight : 0.101 kg
    • [Uimp] Rated Impulse Withstand Voltage : 2.5 kV EN/IEC 60947-5-1
    • Maximum Switching Voltage : 100 V DC
    • [Sa] Assured Operating Distance : 5 mm
    • Cable Material : PVC
    • Breaking Capacity : 10 VA
    • Safety Reliability Data : B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
    • Enclosure Material : thermoplastic PBT
    • Width : 16 mm
    • Depth : 7 mm
    • Electrical Durability : 1200000 cycles
    • Safety Level : can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Product Certifications : UL || CSA
    • Ambient Air Temperature For Operation : -25-85 °C
    • Standards : ISO 14119 || UL 508 || EN/IEC 60204-1 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || EN/ISO 12100
    • Shock Resistance : 30 gn 11 ms IEC 60068-2-27
    • Vibration Resistance : 10 gn 10-150 Hz)IEC 60068-2-6
    • Ip Degree Of Protection : IP67 conforming to IEC 60529
    • Ambient Air Temperature For Storage : -40-85 °C
    • Electrical Shock Protection Class : class II EN/IEC 61140
    • Maximum Sensitivity To Magnetic Fields : 0.3 mT
    • Protective Treatment : TH