module XPSAXE - stop and switch monitoring - 24 V DC/AC

MODULE XPSAXE - STOP AND SWITC

SQDXPSAXE5120C XPSAXE5120C 3389119043007
195.43 / EA
http://schema.org/OutOfStock
  • Certifications: BG, CSA, UL
  • Net Weight: 0.229 kg
  • Operating Temperature: -25-55 °C
  • Standard: EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 13850
  • Storage Temperature: -25-75 °C
  • Warranty Length: 18 mth
This XPSAXE safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
QTY
  • Product Description
  • Specifications
This XPSAXE safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
  • Environment
    • Product Certifications : BG || CSA || UL
    • Ambient Air Temperature For Operation : -25-55 °C
    • Standards : EN/ISO 13850 || EN 1088/ISO 14119 || EN/IEC 60204-1 || EN/IEC 60947-5-1
    • Ip Degree Of Protection : IP20EN/IEC 60529 || IP40EN/IEC 60529
    • Ambient Air Temperature For Storage : -25-75 °C
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1406024EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI1406024EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Complementary
    • [Uc] Control Circuit Voltage : 24 V DC
    • Mounting Support : 35 mm symmetrical DIN rail
    • Output Thermal Current : 6 A instantaneous and time delay outputs
    • Minimum Output Voltage : 17 V relay output
    • Minimum Output Current : 10 mA relay output
    • Associated Fuse Rating : 6 A gG instantaneous outputs
    • [Uimp] Rated Impulse Withstand Voltage : 4 kV III IEC 60947-5-1 || 4 kV III DIN VDE 0110 part 1
    • Net Weight : 0.229 kg
    • [Ui] Rated Insulation Voltage : 300 V 2)IEC 60947-5-1 || 300 V 2)DIN VDE 0110 part 1
    • Local Signalling : 2 LEDs
    • Synchronisation Time Between Inputs : < 0.5 s
    • Breaking Capacity : 1.5 A 24 V DC-13)50 ms relay output
    • Maximum Power Consumption In Va : 4 VA DC
    • Supply Frequency : 50/60 Hz
    • Maximum Response Time On Input Open : 80 ms
    • Breaking Capacity : 3600 VA inrush AC-15 B300 relay output || 360 VA holding AC-15 B300 relay output
  • Specifications
    • [Us] Rated Supply Voltage : 24 V DC - 15...10 % || 24 V AC
    • Range Of Product : Preventa Safety automation
    • Product Or Component Type : Preventa safety module
    • Safety Module Name : XPSAXE
    • Output Type : relay instantaneous opening, 3 NO, volt-free
    • Connections - Terminals : spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end || spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end || spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel || spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel || spring terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel || spring terminals, removable terminal block
    • Number Of Additional Circuits : 1 NC
    • Safety Module Application : for emergency stop and switch monitoring
    • Safety Reliability Data : DC > 99 % EN/ISO 13849-1 || MTTFd = 457 years EN/ISO 13849-1 || PFHd = 3E-8 1/h EN/IEC 62061
    • Safety Level : can reach PL e/category 4 EN/ISO 13849-1 || can reach SILCL 3 EN/IEC 62061