Harmony, 3 phase supply control relay, range 220 to 480 VAC, sequence, phase failure, phase imbalance, voltage

3 PHASE RELAY 250V 5AMP RM35

SQDRM35TF30 RM35TF30 3389119405263
346.86 / EA
http://schema.org/OutOfStock
  • Operating Position: Any Position Without Derating
  • Warranty Length: 18 mth
  • Width: 35 mm
Harmony Control Monitoring and Control Relays (RM17, RM22, RM35) monitor and detect abnormal operating conditions concerning phase ,current, voltage, frequency, speed, or temperature. The relays inform users of abnormal conditions and allow them to initiate the necessary corrective actions before serious and costly breakdown can occur. Harmony phase control relays detect all possible faults occurring in the phases. Harmony voltage and current control relays ensure your equipment is powered with proper values. Harmony frequency control relay monitors frequency variation from your power generation line. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Harmony pump control relay controls and protects your pump from dry running or overloading. Harmony speed control relay picks up the improper rhythm of your process. Harmony temperature control relay for lift application is a dedicated to elevator temperature monitoring (EN81). Harmony temperature control relays are dedicated to temperature regulation (heating, cooling or heating/cooling of processes). These Harmony relays are available in 17.5 mm, 22.5 mm or 35 mm wide housings and are DIN rail mounted. Applications for these Harmony relays include hoisting, construction cranes, harbor cranes, packaging, construction elevators, passenger elevators, escalators, textile, water and waste water. 0 0 0 0 0 0 0
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Maximum Switching Current : 5 A AC, 5 A DC
    • Maximum Switching Voltage : 250 V AC, 250 V DC
    • Us Rated Supply Voltage : , self-powered, , self-powered
    • Control Circuit Frequency : 50...60 Hz +/- 10 %
    • Control Circuit Voltage Limits : - 12 % + 10 % Un
    • Line Rated Current : 5 A
    • Maximum Measuring Cycle : 140 ms measurement cycle as true rms value
    • Minimum Switching Current : 10 mA 5 V DC
    • Uc Control Circuit Voltage : 220...480 V
    • Ui Rated Insulation Voltage : 400 V IEC 60664-1
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electromagnetic Compatibility : emission standard for industrial environments conforming to IEC 61000-6-4, emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3, immunity for industrial environments conforming to IEC 61000-6-2
    • Insulation Resistance : > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60664-1, > 500 MOhm 500 V DC IEC 60664-1, > 500 MOhm 500 V DC IEC 60664-1, > 500 MOhm 500 V DC IEC 60664-1, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60255-5, > 500 MOhm 500 V DC IEC 60664-1
    • Local Signalling : LED (green) for power ON, LED (yellow) for relay ON, LED (yellow) for fault
    • Measurement Error : < 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation, < 1 % over the whole range with voltage variation, 0.05 %/°C with temperature variation
    • Operating Rate : <= 360 operations/hour full load, <= 360 operations/hour full load, <= 360 operations/hour full load, <= 360 operations/hour full load
    • Relay Monitored Parameters : asymmetry, undervoltage and overvoltage in window modephase sequencephase failure detectionasymmetry
    • Repeat Accuracy : 0.3 % time delay, 0.5 % input and measurement circuit
    • Response Time : < 200 ms (in the event of a fault), < 200 ms (in the event of a fault), < 200 ms (in the event of a fault), < 200 ms (in the event of a fault)
    • Safety Reliability Data : MTTFd = 399.5 years, B10d = 360000
    • Threshold Adjustment Voltage : -12...-2 % in the range 220 V AC, +2...+10 % in the range 480 V AC, 2...20 % of Un selected, -12...-2 % in the range 220 V AC, +2...+10 % in the range 480 V AC
    • Utilisation Category : AC-12 IEC 60947-5-1, AC-13 IEC 60947-5-1, AC-14 IEC 60947-5-1, AC-15 IEC 60947-5-1, DC-12 IEC 60947-5-1, DC-13 IEC 60947-5-1
    • Vibration Resistance : 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6, 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1
    • Voltage Detection Threshold : < 194 V, < 194 V
    • Connections Terminals : screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end, screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end, screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end, screw connectors
    • Carbon Footprint Of The Distribution Phase A4 : 0.0167723636, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.0755394545, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.0006485936
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 2.6720909091
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 93 kg CO2 eq., 92.70576
    • Certificate Agency : GL, UL, CSA, GOST, C-tick
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Weee Scope : Out
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1601004EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1918
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • China Rohs Label : 5
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Adjustment Of Asymmetry Threshold : 5...15 % of Un selected
    • Compatibility Code : RM3
    • Contacts Type And Composition : 2 C/O
    • Control Type : without test button
    • Dielectric Test Voltage : 2 kV AC 50 Hz, 1 min
    • Electrical Durability : 100000 cycles
    • Housing Material : polycarbonate
    • Hysteresis : 2-2 %
    • Marking : CE
    • Measurement Range : 220...480 V AC
    • Measurement Voltage Limits : 176-528 V AC
    • Mechanical Durability : 30000000 cycles
    • Mounting Support : 35 mm symmetrical DIN rail conforming to IEC 60715
    • Non Dissipating Shock Wave : 4 kV
    • Operating Position : any position without derating
    • Overvoltage Category : III conforming to IEC 60664-1
    • Power Consumption In Va : 0-22 VA 400 V AC 50 Hz
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : 3-phase control relay
    • Product Specific Application : for 3-phase supply
    • Range Of Product : Harmony Control Relays
    • Relay Name : RM35TF
    • Relay Type : multifunction control relay
    • Reset Time : 1500 ms at 480 V
    • Returnability : Yes
    • Run Up Delay At Power Up : 650 ms
    • Shock Resistance : 15 gn 11 ms IEC 60255-21-1
    • Software Version : EIME v5.8.1
    • Supply Frequency : 50/60 Hz +/- 10 %
    • Supply Voltage Limits : 194-528 V AC, 3 phase
    • Sustainable Packaging : Yes
    • Switching Capacity In Va : 1250 VA
    • Tightening Torque : 0.6-1 N.m IEC 60947-1
    • Time Delay Type : adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault
    • Total Lifecycle Carbon Footprint : 95 kg CO2 eq.
    • Voltage Range : 220...480 V phase to phase
    • Warranty In Months : 18
    • Contacts Composition : 2 C/O
    • Measurement Range 4 : 220...480 V AC
    • Pep Code : ENVPEP1601004EN
    • Database Version : 2016-11
    • Pep Verification Date : 2019-05-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : To switch ON/OFF electrical contacts when the abnormal operating conditions is detected during 10 years and a 100% use rate.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unité (unit)
    • Reference Lifetime In Y2 : 10
    • Energy Consumption On Product Lifetime In Kwh : 189.216
    • Energy Model Manufacturing A1 A3 2 : Energy model used: Indonesia
    • Energy Model Installation A5 2 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model Use B6 2 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity mix; AC; < 1kV; EU-27
    • Offer Owner Code : 190786
    • Pn : 1
    • Width Nominal : 35 mm
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 2 : 1052.28
    • Net Use Of Fresh Water M3 Operational Energy Use B6 2 : 336.1392
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 2 : 345.6432
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 1616.112
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 2 : 1851.552
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 235.44
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 1616.112
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 235.44
    • Air Pollution M3 Operational Energy Use B6 2 : 3990.096
    • Water Pollution M3 Operational Energy Use B6 2 : 3825.36
  • Environment Attributes Main
    • Ambient Air Temperature For Operation : -20-50 °C, -20-50 °C
    • Directives : 89/336/EEC - electromagnetic compatibility, 73/23/EEC - low voltage directive
    • Ip Degree Of Protection : IP20 IEC 60529 terminals), IP30 IEC 60529 casing)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 95.4708113209
    • Ambient Air Temperature For Storage : -40-70 °C
    • Circularity Profile : ENVEOLI1601004EN
    • Environmental Disclosure : ENVPEP1601004EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 95-95 % 55-55 °C IEC 60068-2-30
    • Pep Code : ENVPEP1601004EN
    • Pep Verification Date : 2019-05-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : 3-phase control relay
    • Range Of Product : Harmony Control Relays
  • ETIM
    • ETIM 8 : EC001441
    • ETIM 9 : EC001441
  • Output Attributes
    • Nominal Output Current : 5 A
    • Output Contacts : 2 C/O
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Width : 35 mm
    • Country of Origin : Brazil, France, Indonesia, Mexico, Singapore, United States